Application Information (Continued)
The remaining three LSBs are generated next using the
same eight comparators that were used for the first flash
conversion.As determined by the results of the MSB flash, a
voltage from the MSB Ladder equivalent to the magnitude of
the five MSBs is subtracted from the analog input voltage as
the upper switch is moved from position one to position two.
The resulting remainder voltage is applied to the eight flash
comparators and, with the lower switch in position two, compared with the eight tap points from the LSB Ladder.
By using the same eight comparators for both flash conversions, the number of comparators needed by the multi-step
converter is significantly reduced when compared to standard half-flash techniques.
Voltage Estimator errors as large as 1/16 of V
REF
(16 LSBs)
will be corrected since the flash comparators are connected
to ladder voltages that extend beyond the range specified by
the Voltage Estimator. For example, if 7/16 V
REF
<
V
IN
<
9/16 V
REF
the Voltage Estimator’s comparators tied to the
tap points below 9/16 V
REF
will output “1”s (000111). This is
decoded by the estimator decoder to “10”. The eight flash
comparators will be placed at the MSB Ladder tap points
between
3
⁄8V
REF
and5⁄8V
REF
. The overlap of 1/16 V
REF
on
each side of the Voltage Estimator’s span will automatically
correct an error of up to 16 LSBs (16 LSBs = 312.5 mV for
V
REF
= 5V). If the first flash conversion determines that the
input voltage is between
3
⁄8V
REF
and 4/8 V
REF
− LSB/2, the
Voltage Estimator’s output code will be corrected by subtracting “1”. This results in a corrected value of “01”. If the
first flash conversion determines that the input voltage is
between 8/16 V
REF
− LSB/2 and5⁄8V
REF
, the Voltage Esti-
mator’s output code remains unchanged.
After correction, the 2-bit data from both the Voltage Estima-
tor and the first flash conversion are decoded to produce the
five MSBs. Decoding is similar to that of a 5-bit flash converter since there are 32 tap points on the MSB Ladder.
However, 31 comparators are not needed since the Voltage
Estimator places the eight comparators along the MSB Ladder where reference tap voltages are present that fall above
and below the magnitude of V
IN
. Comparators are not
needed outside this selected range. If a comparator’s output
is a “0”, all comparators above it will also have outputs of “0”
and if a comparator’s output is a “1”, all comparators below it
will also have outputs of “1”.
2.0 DIGITAL INTERFACE
The ADC08061/2 has two basic interface modes which are
selected by connecting the MODE pin to a logic high or low.
2.1 RD Mode
With a logic low applied to the MODE pin, the converter is set
to Read mode. In this configuration (see
Figure 1
), a complete version is done by pulling RD low,and holding low, until
the conversion is complete and output data appears. This
typically takes 655 ns. The INT (interrupt) line goes low at
the end of conversion. A typical delay of 50 ns is needed
between the rising edge of RD (after the end of a conversion)
and the start of the next conversion (by pulling RD low). The
RDY output goes low after the falling edge of CS and goes
high at the end-of-conversion. It can be used to signal a
processor that the converter is busy or serve as a system
Transfer Acknowledge signal. For the ADC08062 the data
generated by the first conversion cycle after power-up is
from an unknown channel.
2.2 RD Mode Pipelined Operation
Applications that require shorter RD pulse widths than those
used in the Read mode as described above can be achieved
by setting RD’s width between 200 ns–400 ns (
Figure 5
). RD
pulse widths outside this range will create conversion linearity errors. These errors are caused by exercising internal
interface logic circuitry using CS and/or RD during a conversion.
When RD goes low, a conversion is initiated and the data
from the previous conversion is available on the DB0–DB7
outputs. Reading D0–D7 for the first two times after
power-up produces random data. The data will be valid
during the third RD pulse that occurs after the first conversion.
2.3 WR-RD (WR then RD) Mode
The ADC08061/2 is in the WR-RD mode with the MODE pin
tied high. A conversion starts on the falling edge of the WR
signal. There are two options for reading the output data
which relate to interface timing. If an interrupt-driven scheme
is desired, the user can wait for the INT output to go low
before reading the conversion result (see
Figure 3
). Typically, INT will go low 520 ns, maximum, after WR ’s rising
edge. However, if a shorter conversion time is desired, the
processor need not wait for INT and can exercise a read
after only 350 ns (see
Figure 2
). If RD is pulled low before
INT goes low, INT will immediately go low and data will
appear at the outputs. This is the fastest operating mode (t
RD
≤ t
INTL
) with a conversion time, including data access time, of
560 ns. Allowing 100 ns for reading the conversion data and
the delay between conversions gives a total throughput time
of 660 ns (throughput rate of 1.5 MHz).
2.4 WR-RD Mode with Reduced Interface
System Connection
CS and RD can be tied low, using only WR to control the
start of conversion for applications that require reduced digital interface while operating in the WR-RD mode (
Figure 4
).
Data will be valid approximately 705 ns following WR ’s
rising edge.
2.5 Multiplexer Addressing
The ADC08062 has 2 multiplexer inputs. These are selected
using the A0 multiplexer channel selection input.
Table 1
shows the input code needed to select a given channel. The
multiplexer address is latched when received but the multiplexer channel is updated after the completion of the current
conversion.
TABLE 1. Multiplexer Addressing
ADC08062 Channel
A0
0V
IN1
1V
IN2
The multiplexer address data must be valid at the time of
RD’s falling edge, remain valid during the conversion, and
can go high after RD goes high when operating in the Read
Mode.
The multiplexer address data should be valid at or before the
time of WR’s falling edge, remain valid while WR is low, and
go invalid after WR goes high when operating in the WR-RD
Mode.
ADC08061/ADC08062