Datasheet ACNM1112 Specification

Page 1
ORDERING INFORMATION
FEATURES
• Best space savings in its class.
• Compact and high-capacity 30A load switching.
• Full line up (High heat-resistant type and SMD type)
• Terminals for PC board pattern designs are easily allocated.
TYPICAL APPLICATIONS
Defogger, Seat heater , Head lamp, Fog lamp, Fan motor, etc.
Contact arrangement*
1
1: 1 Form C 3: 1 Form A 5: 1 Form C high heat-resistant type 7: 1 Form A high heat-resistant type
Packing style*
2
Nil: X:
Z:
Tube packing Tape and reel packing (Reverse NO terminal direction in pull-out direction) Tape and reel packing (Normal NO terminal direction in pull-out direction)
ACNM
Pick-up voltage 1: Max. 7.2V DC
Coil voltage (DC) 12: 12V
Terminal shape Nil: SA:
PC board terminal Surface-mount terminal
Notes: *1. Surface-mount terminal type is available in high heat-resistant type only.
*2. Tube packing: PC board terminal type only Tape and reel packing: Surface-mount type only
MIDDLE LOAD RELAY
FOR SMART J/B
CN-M (ACNM)
CN-M RELAYS (ACNM)
TYPES
1. PC board terminal type
Contact arrangement Nominal coil voltage
1 Form A 1 Form C ACNM1112 ACNM5112
Standard packing; Carton (tube): 50 pcs.; Case: 1,500 pcs.
2. Surface-mount terminal type
ds_61220_en_cnm: 010113J
Contact arrangement Nominal coil voltage
1 Form A
1 Form C
*2.An “X” at the end of the part number indicates, for tape and r eel packing, reverse NO terminal direction in pull-out direction.
A “Z” at the end of the part number indicates, for t ape and reel packing, normal NO terminal direction in pull-out direction.
12V DC
12V DC
Part No.
Standard type High heat-resistant type
ACNM3112 ACNM7112
Part No.
High heat-resistant type
ACNM7112SAX ACNM7112SAZ ACNM5112SAX ACNM5112SAZ
1
Page 2
CN-M (ACNM)
1-(1). Coil temperature rise
Sample: ACNM1112, 3pcs Measured portion: Inside the coil Contact carrying current: 10A, 20A, 30A Ambient temperature: 26C 78.8F
1-(2). Coil temperature rise
Sample: ACNM7112, 3pcs Measured portion: Inside the coil Contact carrying current: 10A, 20A Ambient temperature: 110C 230F
2. Ambient temperature and operating voltage range
0
140
80
60
40
20
12 14 16 1810
10A
20A
30A
100
120
Coil applied voltage, V
Temperature rise, °C
0
140
120
100
80
60
40
20
12 14 16 1810
10A
20A
Coil applied voltage, V
Temperature rise, °C
-40 -20 0 20 40 60 80 100 120
20
15
10
5
0
Pick-up voltage (cold start)
Ambient temperature, °C
Coil applied voltage, VDC
Operating voltage range
RATING
1. Coil data
Nominal coil voltage
12 V DC
Pick-up voltage
(at 20C 68F) Max. 7.2 V DC
(Initial)
Drop-out voltage
(at 20C 68F) Min. 1.0 V DC
(Initial)
Nominal operating
current [10%] (at 20C 68F)
53.3 mA 225 640 mW 10 to 16 V DC
2. Specifications
Characteristics Item Specifications
Arrangement 1 Form A, 1 Form C
Contact
Rating
Electrical characteristics
Mechanical characteristics
Expected life
Conditions Conditions for operation, transport and storage
Unit weight Approx. 5.5 g .19 oz
Note: *This value can change due to the switching frequency , envi ronmental condition s, and desired reliab ility level, therefore it is recommended to check this with the actual
load.
Contact resistance (Initial) Typical 5m (By voltage drop 6 V DC 1 A) Contact material Ag alloy (Cadmium free) Nominal switching capacity (resistive load) N.O.: 30A 14V DC, N.C.: 15A 14V DC
N.O. 30A/1 h, 40A/2 min. at 20C 68F 25A/1 h, 35A/2 min. at 85C 185F
Max. carrying current (at 14V DC)
20A/1 h, 30A/2 min. at 110C 230F (High heat-resistant type) N.C. 25A/1 h, 30A/2 min. at 20C 68F 20A/1 h, 25A/2 min. at 85C 185F
15A/1 h, 20A/2 min. at 110C 230F (High heat-resistant type) Nominal operating power 640 mW Min. switching capacity (resistive load)* 1A 12V DC Insulation resistance (Initial) Min. 100 M (at 500 V DC)
Breakdown voltage (Initial)
Between open contacts 500 Vrms for 1 min. (Detection current: 10mA)
Between contacts and coil 500 Vrms for 1 min. (Detection current: 10mA) Operate time (at nominal voltage) Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial) Release time (at nominal voltage) Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial) (without diode)
Shock resistance
Vibration resistance
Functional Min. 100 m/s
Destructive Min. 1,000 m/s
Functional 10 Hz to 100 Hz, Min. 44.1m/s
Destructive
10 Hz to 500 Hz, Min. 44.1m/s Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Mechanical Min. 10
<Resistive load> Min. 10
Electrical
<Motor load> Min. 210
<Lamp load> Min. 10
Standard type; Ambient temp: –40C to +85C –40F to +185F, Humidity: 5 to 85% R.H. High heat-resistant type; Ambient temp: –40C to +110C –40F to +230F, Humidity: 2 to 85% R.H. (Not freezing and condensing at low temperature)
2
{10G} (Half-wave pulse of sine wave: 11ms; detection time: 10s)
2
{100G} (Half-wave pulse of sine wave: 6ms)
7
(at 120 cpm)
5
(At nominal switching capacity, operating frequency: 1s ON, 2s OFF)
5
: at 80 A (inrush), 16 A (steady), 14 V DC (Operating frequency: 2s ON, 6s OFF)
5
: at 84 A (inrush), 12 A (steady), 14 V DC (Operating frequency: 1s ON, 14s OFF)
Coil resistance
[10%]
(at 20C 68F)
2
{4.5G} (Detection time: 10s)
2
{4.5G}
Nominal operating
power
(at 20C 68F)
Usable voltage range
REFERENCE DATA
2
ds_61220_en_cnm: 010113J
Page 3
CN-M (ACNM)
3. Distribution of pick-up and drop-out voltage
Sample: ACNM1112, 20pcs.
4. Distribution of operate and release time
Sample: ACNM1112, 20pcs.
0
10
5
15
20
0 1 2.0 3.0 5.04.0 6.0 7.0 8.0
Voltage, V
Quantity, n
Pick-up voltage Drop-out voltage
8.0
20
15
10
5
0
0 1 2.0 3.0 4.0 5.0 6.0 7.0
Time, ms
Quantity, n
Operate time Release time
5-(1). Electrical life test (Resistive load)
Sample: ACNM1112, 3pcs. Load: Resistive load (NO side: 30A 14V DC) Operating frequency: (ON:OFF = 1s:1s) Ambient temperature: Room temperature
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
14V DC
0105
6
7
4
2
3
5
1
0
Pick-up and drop-out voltage, V
No. of operations, × 10
4
Pick-up voltage
Drop-out voltage
Contact welding: 0 time
Miscontact: 0 time
Max. x Min.
Max. x Min.
0105
20
30
10
15
25
5
0
No. of operations,
× 10
4
Max. x
Min.
Contact resistance, mΩ
5-(2). Electrical life test (Motor load)
Sample: ACNM7112, 3pcs. Load: inrush: 80A/steady: 16A, radiator fan actual load (motor free) Switching frequency: (ON:OFF = 2s:6s) Ambient temperature: 110C 230F
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
14V DC
M
02010
6
7
4
2
3
5
1
0
Pick-up and drop-out voltage, V
No. of operations, × 10
4
Pick-up voltage
Drop-out voltage
Contact welding: 0 time
Miscontact: 0 time
Max x Min.
Max x Min.
02010
20
30
10
15
25
5
0
No. of operations,
× 10
4
Contact resistance, mΩ
Max x Min.
5-(3). Electrical life test (Lamp load)
Sample: ACNM3112, 3pcs. Load: inrush: 84A/steady: 12A Switching frequency: (ON:OFF = 1s:14s) Ambient temperature: Room temperature
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
0105
6
7
4
2
3
5
1
0
Pick-up and drop-out voltage, V
No. of operations, × 10
4
Pick-up voltage
Drop-out voltage
Contact welding: 0 time
Miscontact: 0 time
Max x Min.
Max x Min.
0105
20
30
10
15
25
5
0
No. of operations, × 10
4
Contact resistance, mΩ
Max x Min.
14V DC
ds_61220_en_cnm: 010113J
60W 60W
3
Page 4
CN-M (ACNM)
Download from our Web site.
CAD Data
External dimensions
10.95
.431
4.65
.183
2.95
.116
1.2
1.2
A
11
.433
15.5
.610
1.2
.047
.047
.047
Pre-soldering
Max. 1.0 .039
3.5
14.4
.138
.567
0.4
.016
8
.315
Dimension: General tolerance Max. 1mm .039 inch: 0.1 .004 1 to 3mm .039 to .118 inch: 0.2 .008 Min. 3mm .118 inch: 0.3 .012
PC board pattern
(Bottom view)
1 Form A
1 Form C
4.65
.183
10.95
.431
5x1.5 dia.
8
.315
+0.1
0
5x.059 dia.
+.004
0
4.65
.183
10.95
.431
6x1.5 dia.
8
.315
+0.1
0
6x.059 dia.
+.004
0
Schematic
(Bottom view)
1 Form A
1 Form C
COM NCCOIL
COM NOCOIL
COM NCCOIL
COM NOCOIL
Tolerance: 0.1 .004
*Dimensions (thickness and width) of terminal specified in this catalog is measured before pre-soldering.
Intervals between terminals is measured at A surface level.
CAD Data
External dimensions
11
10.95
.431
4.65
.183
2.95
.116
14.8
.583
1.2
1.2
15.5
.433.610
1.2
.047
.047
.047
Pre-soldering
0.1
15.1
14.4
.594
.567
8
.315
Dimension: General tolerance Max. 1mm .039 inch: 0.1 .004 1 to 3mm .039 to .118 inch: 0.2 .008 Min. 3mm .118 inch: 0.3 .012
Recommended mounting pad
(Top view)
1 Form A
1 Form C
5x1.7
5x.067
11.2
4.6
.441
.181
4.65
.183
10.95
.431
6x1.7
6x.067
11.2
4.6
.441
.181
4.65
.183
10.95
.431
Schematic
(Top view)
1 Form A
1 Form C
COM NOCOIL
COM COIL
COM NOCOIL
COM NCCOIL
Tolerance: 0.1 .004
DIMENSIONS (mm inch)
1. PC board terminal type
CAD Data
CAD Data
2. Surface-mount terminal type
4
ds_61220_en_cnm: 010113J
Page 5
NOTES
1. Usage, transport and storage conditions
1) Ambient temperature, humidity, and atmospheric pressure during usage, transport, and storage of the relay: (1) Temperature: –40 to +85C –40 to +185F (Standard type) –40 to +110C –40 to +230F (High heat-resistant type) (2) Humidity: 2 to 85% RH (Avoid freezing and condensation.) (3) Atmospheric pressure: 86 to 106 kPa The humidity range varies with the temperature. Use within the range indicated in the graph below. (Temperature and humidity range for usage, transport, and storage)
2. Storage condition after opening a moisture-prevention package
(1) After opening a moisture-prevention package, use the item as soon as possible (within 3 days under an environment of Max. 30C 86F, Max. 70% RH). (2) If products are not used within 3 days after opening a moisture-prevention package, store them in a humidity­controlled desiccator or in a storage bag with silica gel.
3. Mounting and cleaning conditions for surface-mount terminal type relays
1) Recommended reflow condition is:
• Reflow-soldering temperature profile condition (IRS method)
• Cautions for mounting operations Temperature profile indicates the temperature of the soldered part (*1) of terminals on the surface of a circuit board. The exterior temperature of a relay may be extremely high depending on the component density on the board or the heating method of the reflow oven or circuit board type. Sufficient verification under actual processing conditions is required.
2) Avoid cleaning (ultrasonic cleaning, boiling cleaning, etc.) and coating in order to prevent negative impacts on relay characteristics.
85
5
Humidity, %RH
Tolerance range
(Avoid condensation when used at temperatures higher than 0°C 32°F)
(Avoid freezing when used at temperatures lower than 0°C 32°F)
850–40
+185+32–40
Temperature, °C °F
CN-M (ACNM)
Humidity, %RH
(Avoid freezing when used at temperatures lower than 0°C 32°F)
85
Tolerance range
(Avoid condensation when used at temperatures higher than
5
0°C 32°F)
2
Temperature, °C °F
T
3
T
2
T
1
110850–40
+230+185+32–40
T1 = 150 to 180°C
2
= 230°C
T
3
= Less than 250°C
T
1
= 60 to 120 sec.
t
2
= Less than 30 sec.
t
t
1
302 to 356°F
446°F or more
482°F
t
2
*1
For Cautions for Use, see Relay Technical Information.
ds_61220_en_cnm: 010113J
5
Loading...