60
AC/DC Power Supplies
100 and 150 WATT
ORDERING GUIDE: Series/Input Code/Output Code
Example: ACE 102 - 100 Watt Series, 110VAC Input, 12 Volt Output @ 9 AMPS
FEATURES
• Efficiency to 88% • Remote Sense
• Adjustable Outputs • Remote Disable
• Soft Start • Input/Output Protection
• Internal EMI/RFI Filter • Compact Size/Light Weight
Input Code Input Range
1 90-132 VAC, 110-175 VDC (47-440 Hz)
2 180-264 VAC, (47-440 Hz)
Series Output
ACE 100 Watts
ACF 150 Watts
Output Code
From Chart
Below
SERIES ACE ACF
OUTPUT OUTPUT OUTPUT OUTPUT
CODE VOLTAGE(S) CURRENT CURRENT
01 5VDC 20A 30A
02 12VDC 9A 14A
03 15VDC 7A 11A
04 24VDC 5A 7A
10 48VDC 2A 4A
** For 110/220 selectable inputs add suffix "S" to part number.
260 Hopping Brook Road
Holliston, Massachusetts 01746
Tel. (508) 429-4440 Fax (800) 226-2100
http://www.intlpower.com
International
Power Sources, Inc.

ACE ACF
61
OUTPUT SPECIFICATIONS
Voltage Adjustment ±10%
Line Regulation .8%
Load Regulation .9%
Ripple and Noise (DC-100MHz) 1% of VOUT & 50mV p-p
Temperature Coefficient .03%/°C
Overvoltage Protection Output Shutdown
Short Circuit Protection Foldback Current Limit
Remote Sense Standard
Remote Disable Connect RC to (-)S
Rise Time 100ms Max.
Hold Up Time 20msec.
INPUT SPECIFICATIONS
Input Voltage Range See Table
Input Filter FCC Class A/EMI/RFI
Input Inrush Current 20 Amps Max
Input Protection Input Fuse
GENERAL SPECIFICATIONS
Switching Frequency 80 kHz Typical
Efficiency 85% Typical
Isolation (Input-Output-Case) 500VDC (50Mohm)
Weight 1.7 lbs 3.1 lbs.
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature 0°C to 50°C (to 60°C @ 50% Load)
Storage Temperature -40°C to 85°C
Humidity 85%
Vibration (5-10Hz) 10mm, (10-55Hz) 2G
Shock 30G
Safety UL 1012 Compliance
ELECTRICAL SPECIFICATIONS
All specifications typical at nominal line, full load and 25°C
TERMINAL ACE ACF
1 +Vout +Vout
2 +Vout +Vout
3 -Vout +S
4 -Vout -S
5 Filter Gnd (LFG) -Vout
6 ACin -Vout
7 ACin RC
8 Case Gnd (FG) ACin
9 — ACin
10 — Case Gnd (FG)
Specifications subject to change