Datasheet ACC210, ACC208, ACC207, ACC206, ACC205 Datasheet (IPSI)

...
Page 1
15-25-50 Watts
ACA/ACB/ACC Series
Efficiency to 85%
Adjustable Outputs
Internal EMI/RFI Filter
Isolated Outputs
Input/Output Protection
Specification
Input
Input Voltage Range • See Table Soft Start All Models Input Filter π Network Input Protection Input Fuse
Output
Voltage Adjustment ±5% See Note 1 Line Regulation 0.8%
(Full Input Range) Load Regulation 0.9%
(No Load-Full Load) Ripple & Noise 1% of VOUT & 50mV p-p
(DC-100MHz) Temperature 0.03%/°C
Coefficient Overvoltage • Zener Diode
Protection Short Circuit Foldback Current Limit
Protection Hold Up Time 10 ms Minimum Rise Time 200 ms Maximum
General
Switching 50 kHz Typical Frequency
Efficiency 75% Typical Isolation 50 Mohm (500 VDC)
(Input-Output-Case) Weight ACA 250g, ACB 350g, ACC 470g
Environmental
Operating 0°C to 50°C (no derating) Temperature
Storage -20°C to 85°C Temperature
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA
www.XP-iQ.com
Intelligent Design Quality Product
XPiQ inc.
AC/DC Chassis Mount
222
Page 2
Mechanical Details
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA
www.XP-iQ.com
OUTPUT VOLTAGE & CURRENT RATINGS ACA/ACB/ACC 15/25/50
Series ACA ACB ACC
Output Code Output Voltages Output Current(s) Output Current(s) Output Current(s)
01 5 VDC 3.00 A 5.0 A 10.0 A 02 12 VDC 1.20 A 2.1 A 4.20 A 03 15 VDC 1.00 A 1.7 A 3.40 A 04 24 VDC 0.62 A 1.1 A 2.50 A
05
+12 VDC 0.75 A 1.2 A 2.00 A (Pk 3.50 A)
-12 VDC 0.50 A 0.9 A 1.70 A
06
+15 VDC 0.50 A 1.0 A 1.70 A
-15 VDC 0.50 A 0.7 A 1.30 A 5 VDC 1.80 A 2.8 A 5.00 A
07 +12 VDC 0.15 A 0.5 A 0.83 A
-12 VDC 0.15 A 0.4 A 0.83 A 5 VDC 1.80 A 2.8 A 5.00 A
08 +15 VDC 0.15 A 0.5 A 0.65 A
-15 VDC 0.15 A 0.4 A 0.65 A
10 48 VDC - 0.5 A 1.00 A
Single output models only, for optional 110/220 selectable inputs add suffix “S” to part number.
1. ACA Triple output - no adjustment ACB /ACC triple outputs - only 5 VDC adjustable
Dimension ACA ACB ACC
A 4.64 (118.0) 5.31 (135.0) 6.30 (160.0) B 3.15 (80.0) 3.35 (85.0) 3.78 (96.0) C 0.98 (25.0) 1.22 (31.0) 1.30 (33.0) D 2.76 (70.0) 2.76 (70.0) 3.94 (100.0) E 2.05 (52.0) 2.20 (56.0) 2.40 (61.0) F 1.30 (33.0) 1.28 (32.5) 1.18 (30.0) G 3.74 (95.0) 4.65 (118.0) H 0.28 (7.0) 0.39 (10.0)
I 0.39 (10.0) 0.39 (10.0)
Series ACA ACB ACC
Terminal Single Dual Triple Single Dual Triple Single Dual Triple
Output Output Output Output Output Output Output Output Output
0- -Case Gnd (FG) Case Gnd (FG) - Case Gnd (FG) - - Case Gnd (FG) 1AC AC AC AC AC ACCase Gnd (FG) AC AC 2AC AC AC AC AC AC AC AC AC 3
Case Gnd (FG) Case Gnd (FG)
-V
3
Filter Gnd (FG) Case Gnd (FG) -V
3
AC Case Gnd (FG) -V
3
4 - -VOUT -V
2
-+V2-V
2,3
Common Filter Gnd (FG) +V
2
V
2,3
Common
5 -VOUT Common Common - +V
1
+V
2
-VOUT -V
2
+V
2
6 +VOUT +VOUT -V
1
-VOUT +V
1
+V
1
+VOUT +V
1
+V
1
7 - - - +VOUT -V
1
-V
1
- -V
1
+V
1
Ordering Guide: Series/Input Code
Example: ACC 102-50 Watt Series, 110 VAC Input, 12 Volt Output @ 4.2 AMPS
Series Output
ACA 15 Watts ACB 25 Watts ACC 50 Watts
Input Code Input Range
1 90-132 VAC, 110-175 VDC (47-440 Hz) 2 180-264 VAC, 220-350 VDC (47-440 Hz)
Output Code
From Chart
Above
112