Datasheet A4825, A4875 Specification

Page 1
DataSheet
Series 1 480 VAC
Panel Mount
Ratings from 25A to 90A @ 48-530 VAC
SCR output for heavy industrial loads
Zero turn-on or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
AC or DC control
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Redesigned housing with anti-rotation barriers
PRODUCT SELECTION
4-32 VDC D4825 D4850 D4875 D4890 90-280 VAC A4825 A4850 A4875 A4890
90A75A50A25AControl Voltage
AVAILABLE OPTIONS
Termination
Control Voltage A: 90-280 VAC D: 4-32 VDC
A
Required for valid part number For options only and not required for valid part number
48
Operating Voltage 48: 48-530 VAC
10
Rated Load Current 25: 25 Amps 50: 50 Amps 75: 75 Amps 90: 90 Amps
Blank: Screw F: Quick Connect (7) K: Round standoffs
K HS
Thermal Pad Blank: Not Included H: Included
Snubber Blank: Not Included S: Included
-10
Switching Type Blank: Zero Voltage Turn-On
-10: Instantaneous Turn-On (8)
OUTPUT SPECIFICATIONS
Operating Voltage (47-440Hz) [Vrms] (2) 48-530 48-530 48-530 48-530 Transient Overvoltage [Vpk] 800 800 800 800 Maximum Off-State Leakage Current @ Rated Voltage [mArms] (3) 1 1 1 1 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] 500 500 500 500 Maximum Load Current [Arms] (4) 25 50 75 90 Minimum Load Current [mArms] 150 150 150 150 Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 239/250 597/625 954/1000 1145/1200 Maximum On-State Voltage Drop @ Rated Current [Vrms] 1.15 1.15 1.15 1.15 Thermal Resistance Junction to Case (Rjc) [°C/W] Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] Minimum Power Factor (at Maximum Load) 0.5 0.5 0.5 0.5
INPUT SPECIFICATIONS
Description D48xx A48xx
Control Voltage Range 4-32 VDC 90-280 Vrms (60Hz) Maximum Reverse Voltage -32 ­Minimum Turn-On Voltage 4.0 VDC (5) 90 Vrms Minimum Turn-Off Voltage 1.0 VDC 10 Vrms Minimum Input Current 7.0 mA 5.0 mA Maximum Input Current 12 mA 10 mA Nominal Input Impedance Current Regulated Current Regulated Maximum Turn-On Time [msec] 1/2 Cycle (6) 20 Maximum Turn-Off Time [msec] 1/2 Cycle 30
(1)
90A75A50A25ADescription
0.8 0.45 0.3 0.27
285/259 1770/1621 4555/4150 6560/5976
(1)
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
Page 2
Panel Mount
DataSheet
GENERAL SPECIFICATIONS
(1)
ParametersDescription
Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -40 to 80 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 2.6 oz (74.9 g) Housing Material 94 V-0 Baseplate Material Aluminum Input Terminal Screw Torque Range (in-lbs/Nm) 13-15 /1.5-1.7 Load Terminal Screw Torque Range (in-lbs/Nm) 18-20 / 2.0-2.2 SSR Mounting Screw Torque Range (in-lbs/Nm) 18-20 / 2.0-2.2 Humidity 85% non-condensing
9
10
Ohm
WIRING DIAGRAM
AC
V
Load
1 ( ) 2 ( )
2
OUTPUT
1
SOLI D ST AT E R ELA Y
4
INPUT
3
(10)
Terminals
Input
Output
Recommended Wire Sizes
Wire Size
(Solid / Stranded)
24 AWG (0.2 mm
2 x 12 AWG (3.3 mm
20 AWG (0.5 mm
2 x 10 AWG (5.3 mm
2 x 8 AWG (8.4 mm
2
) / 0.2 [minimum]
2
2
) / 0.518 [minimum]
2
2
) / 8.4 [maximum]
) / 3.3 [maximum]
) / 5.3
Wire Pull-Out
Strength (lbs)[N]
10 [44.5]
90 [400]
30 [133]
110 [490]
90 [400]
25
20
15
10
Input Current (mA)
5
Input Current vs Input Voltage
Standard Regulated “DC” Inputs
005 10 15 20 25 30
DC Input Voltage
4 (– / ) 3 (+ / )
EQUIVALENT CIRCUIT BLOCK DIAGRAMS
Diagram: Series 1 DC
4
-
DC
Trigger Circuit
3
+DC
Current
Limiter
Diagram: Series 1 AC
1
AC
(9)
2
AC
4
AC
AC
3
AC/DC
Converter
Current Limiter
Trigger Circuit
1
AC
(9)
AC
2
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
Page 3
Panel Mount
DataSheet
MECHANICAL SPECIFICATIONS
(1)
Screw Termination
1.1
1.88
[47.6]
[27.9]
0.49
[12.4]
OUTPUT
1
S OLID ST AT E RELA Y
4
INPUT
1.0
[25.4]
1.75
[44.5]
Mounting Hole/Slot
0.18 [4.5] DIA.
2
1.7
[43.2]
3
Mounting Hole/Slot
r 0.09 [2.2]
Quick Connect Termination (“F” Option) - Up to 25 Amp (7)
Mounting Hole/Slot
0.18 [4.5] DIA.
1.1
[27.9]
0.49
[12.4]
8-32 Output Screw
(2 places)
Faston Terminal
0.25 x 0.032
(2 places)
[23.3]
1.31
[33.4]
0.89
[22.6]
0.92
2.25
[57.3]
Round Standoff Termination (“K” Option)
1.1
1.88
[47.6]
[27.9]
0.49
[12.4]
OUTPUT
1
S OLID ST AT E RELA Y
4
INPUT
1.0
[25.4]
1.75
[44.5]
Mounting Hole/Slot
0.18 [4.5] DIA.
2
1.7
[43.2]
3
Mounting Hole/Slot
r 0.09 [2.2]
Quick Connect Termination (“F” Option) - Up to 50 Amp (7)
Mounting Hole/Slot
0.18 [4.5] DIA.
1.1
[27.9]
0.49
[12.4]
8-32 Output Screw
(2 places)
Faston Terminal
0.25 x 0.032
(4 places)
1.08
[27.5]
2.25
[57.3]
0.89
[22.6]
1.31
[33.4]
2
3
6-32 Input Screw
(2 places)
Faston Terminal
0.187 x 0.032 (2 places)
1.7
[43.2]
2.25
[57.3]
0.89
[22.6]
1.25
[31.8]
1.88
[47.6]
Mounting
Hole/Slot
r 0.09 [2.2]
OUTPUT
1
S OLID ST AT E RELA Y
4
INPUT
1.0
[25.4]
1.75
[44.5]
GENERAL NOTES
(1) All parameters at 25°C unless otherwise specified. (2) For “S” option, operating voltage frequency is 47-63Hz. (3) For parts with option “S” maximum leakage current is 10mA. (4) Heat sinking required, see derating curves. (5) Increase minimum voltage by 1V for operations from -20 to -40°C. (6) Turn-on time for Instantaneous turn-on versions is 0.02 msec (DC Control Models). (7) Single pair (up to 25A) Double pair* (50A model only). *Caution: User must connect to both pairs. (8) Instantaneous turn-on not recomended for capacitive loads. Use zero turn-on only. (9) Elective Internal Snubber, “S” option. (10) Load can be wired to either SSR output terminal 1 or 2.
1.88
[47.6]
Mounting
Hole/Slot
r 0.09 [2.2]
OUTPUT
1
S OLID ST AT E RELA Y
4
INPUT
1.0
[25.4]
1.75
[44.5]
2
3
6-32 Input Screw
(2 places)
Faston Terminal
0.187 x 0.032 (2 places)
1.7
[43.2]
2.25
[57.3]
0.89
[22.6]
1.25
[31.8]
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
Page 4
SURGE CURRENT INFORMATION
Panel Mount
DataSheet
250
200
150
100
50
Surge Current (Amp)
0
0.01 0.1 1 10
Surge Duration (Secs)
75 A
900 800 700 600 500 400 300 200
Surge Current (Amp)
100
0
25 A
0.01 0.1 1 10
Non repetitive peak surge current at Tj initial 40ºC.
Surge Duration (Secs)
600
500
400
300
200
100
Surge Current (Amp)
0
0.01 0.1 1 10
Surge Duration (Secs)
90 A
1200 1050
900 750 600 450 300
Surge Current (Amp)
150
0
50 A
0.01 0.1 1 10
Surge Duration (Secs)
THERMAL DERATE INFORMATION
1.5ºC/W
25
20
15
10
5
Load Current (Amps)
0
20 30 40 50 60 70 80
75
60
45
30
15
Load Current (Amps)
0
20 30 40 50 60 70 80
Ambient Temperature (ºC)
0.5ºC/W
0.7ºC/W
Ambient Temperature (ºC)
25 A
2ºC/W
75 A
1ºC/W
3ºC/W
1.5ºC/W
50 A
0.7ºC/W
50
40
30
20
10
Load Current (Amps)
0
20 30 40 50 60 70 80
1ºC/W
Ambient Temperature (ºC)
1.5ºC/W
90 A
0.5ºC/W
90 80 70 60 50 40 30 20 10
Load Current (Amps)
0
20 30 40 50 60 70 80
0.7ºC/W
Ambient Temperature (ºC)
1ºC/W
2ºC/W
1.5ºC/W
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
Page 5
AGENCY APPROVALS
EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 IEC 60068-2-6 : Vibration 0.33mm and 0.75 mm Amplitude over 10-55 Hz IEC 60068-2-27 : Shock Resistance 15g/11ms
E116949 LR81689 10143 UG
ACCESORIES
New Accessories!
Protective Cover & Hardware Kits
Panel Mount
DataSheet
Recommended Accessories
Protective Cover
Part number: KS101
Clear plastic cover compatible with all new S1 designs. Safety covers provide added protection from electric shock when installing or checking equipment.
Hardware Kit
Part number: HK3
Bag with 2 threaded standoffs, 2 screws 8-32 x 1/4, and 2 lockwashers M8 for output, and 2 threaded standoffs, 2 screws 6-32 x 3/16, and 2
lockwashers M6 for input. Standoff screws provide additional mounting options such as "dead bug" mounting, using lug terminals or wire terminals to the side of the relay.
Hardware Kit
Part number: HK4
Bag with 2 square brass
accessories and 2 screw
8-32 x 5/8 for output. Used
to mount TMR1 lug
terminals.
Cover Hardware
Kit
KS101 HK1
HK3
HK4
Heat Sink
Part No.
HS501DR
HS301 / HS301DR
HS251
HS201 / HS201DR
HS172
HS151 / HS151DR
HS103 / HS103DR
HS072
HS053
Thermal Resistance
[ºC/W]
5.0
3.0
2.5
2.0
1.7
1.5
1.0
0.7
0.5
Lug Terminal Thermal Pad
TRM1
TRM6
HSP-1
HSP-2
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
Rev. 082213
Page 6
Panel Mount
DataSheet
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.
Disconnect all power before installing or working with this equipment.
Verify all connections and replace all covers before turning on power.
Failure to follow these instructions will result in death or serious injury.
RIESGO DE DESCARGA ELECTRICA O EXPLOSION.
Desconectar todos los suministros de energia a este equipo antes de trabajar
con este equipo.
Verificar todas las
conexiones y colocar todas las tapas antes
de energizer el equipo.
El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias.
RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION
Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil
Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous
De non-suivi de
ces instructions provoquera la mort ou des lésions sérieuses sérieuses.
GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION.
Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor
Sie an dem
Gerät Arbeiten durchführen
Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen.
Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen.
RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSI ONE.
Spenga tutta l'alimentazion e che fornisce questa apparecchiatu ra prima del lavorare a questa
apparecchiatu ra
Verificare tutti i colle
gamenti e sostituire tutte le coperture prima della rotazione sull'alimentazi one
L'omissione di seguire queste istruz ioni provocherà la morte o di lesioni serie
存在电击、 爆炸或电弧 闪烁危险
在操作此设 备之前请先 关闭电源。
若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡。
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告
RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
The product's side panels may be hot, allow the product to cool before touching.
Follow proper mounting instructions including torque values.
Do not allow liquids or foreign objects to enter this product.
Failure to follow these instructions can result in serious injury, or equipment damage.
RIESGO DE DAÑOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD
Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo.
Respetar las instrucciones de montaje, y en particular los pares de apretado.
No dejar que penetren líquidos o cuerpos extraños en el producto.
Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales.
RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER
Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher.
Respecter les consignes de montage, et notamment les couples de serrage.
Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit.
Le non-respect de cette directive peut entraîner, des lésions corporelles graves ou des dommages matériels.
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO
I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo.
Seguire le istruzioni di montaggio corrette.
Non far entrare liquidi o oggetti estranei in questo
apparecchio.
La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature.
GEFAHR VON MATERIALSCHÄDEN UND GEHÄUSEERHITZUNG
Die Seitenwände können heiß sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren.
Beachten Sie die Montageanweisungen,
Führen Sie keine Flüssigkeiten oder
Fremdkörper in das Produkt ein.
Die Nichtbeachtung dieser Anweisung kann Körperverletzung oder Materialschäden zur Folge haben.
材料损坏和高温外壳的危险性
产品的一侧面板可能很热,在其冷却前请 不要触碰。
遵照正确的安装说明,包括扭矩值。
请勿让液体及其他异物进入本产品。
如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏。
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
Page 7
Panel Mount
DataSheet
ANNEX - ENVIROMENTAL INFORMATION
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.
Part Name
Semiconductor die
Solder
附件 - 环保信息
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。
名称 六价铬 多溴联苯 多溴二苯醚
半导体芯片 焊接点
Toxic or hazardous Substance and Elements
Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd)
(Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE)
Chromium (Cr (VI))
有毒有害物质或元素
biphenyls (PBB)
diphenyl ethers (PBDE)
50
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
Loading...