Datasheet A3189LUA, A3189LU, A3189LLT, A3189EUA, A3189EU Datasheet (Allegro)

...
HALL-EFFECT LATCHES
FOR HIGH-TEMPERATURE OPERATION
These Hall-effect latches are extremely temperature-stable and stress­resistant sensors especially suited for operation over extended temperature ranges to +150°C. Superior high-temperature performance is made possible through a novel Schmitt trigger circuit that maintains operate and release point symmetry by compensating for temperature changes in the Hall ele­ment. Additionally, internal compensation provides magnetic switch points that become more sensitive with temperature, hence offsetting the usual degradation of the magnetic field with temperature. The symmetry capability makes these devices ideal for use in pulse-counting applications where duty cycle is an important parameter. The four basic devices (3185, 3187, 3188, and 3189) are identical except for magnetic switch points.
Each device includes on a single silicon chip a voltage regulator, qua­dratic Hall-voltage generator, temperature compensation circuit, signal amplifier, Schmitt trigger, and a buffered open-collector output to sink up to 25 mA. The on-board regulator permits operation with supply voltages of 3.8 to 24 volts.
The first character of the part number suffix determines the device operating temperature range. Suffix ‘E–’ is for -40°C to +85°C, and suffix ‘L–’ is for -40°C to +150°C. Three package styles provide a magnetically optimized package for most applications. Suffix ‘–LT’ is a miniature SOT­89/TO-243AA transistor package for surface-mount applications; suffix ‘–U’ is a three-lead plastic mini-SIP, while suffix ‘–UA’ is a three-lead ultra-mini­SIP.
Data Sheet
27609.2A
ABSOLUTE MAXIMUM RATINGS
at TA = +25°C
Supply Voltage, VCC............................ 30 V
Reverse Battery Voltage, V
RCC
........... -30 V
Magnetic Flux Density, B ........... Unlimited
Output OFF Voltage, V
OUT
.................. 30 V
Reverse Output Voltage, V
OUT
.......... -0.5 V
Continuous Output Current, I
OUT
..... 25 mA
Operating Temperature Range, T
A
Suffix ‘E–’ ................... -40°C to +85°C
Suffix ‘L–’ ................. -40°C to +150°C
Storage Temperature Range,
TS............................... -65°C to +170°C
FEATURES
Symmetrical Switch Points
Superior Temperature Stability
Operation From Unregulated Supply
Open-Collector 25 mA Output
Reverse Battery Protection
Activate With Small, Commercially Available Permanent Magnets
Solid-State Reliability
Small Size
Resistant to Physical Stress
Pinning is shown viewed from branded side.
Always order by complete part number: the prefix ‘A’ + the basic four-digit part number + a suffix to indicate operating temperature range + a suffix to indicate package style, e.g., A3185ELT .
3185
THRU
3189
Dwg. PH-003A
1
SUPPLY
V
CC
GROUND
32
OUTPUT
X
3185
THRU
3189
HALL-EFFECT LATCHES FOR HIGH-TEMPERATURE OPERATION
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
ELECTRICAL CHARACTERISTICS over operating temperature range, at V
CC
= 12 V.
Limits
Characteristic Symbol Test Conditions Min. Typ. Max. Units
Supply Voltage V
CC
Operating 3.8 24 V
Output Saturation Voltage V
OUT(SAT)
I
OUT
= 20 mA, B > B
OP
175 400 mV
Output Leakage Current I
OFF
V
OUT
= 24 V, B < B
RP
0.05 5.0 µA
Supply Current I
CC
B < BRP (Output OFF) 4.75 8.0 mA
B > B
OP
(Output ON) 5.7 mA
Output Rise Time t
r
RL = 820 , CL = 20 pF 100 ns
Output Fall Time t
f
RL = 820 , CL = 20 pF 100 ns
MAGNETIC CHARACTERISTICS in gauss over operating supply voltage range.
Part Numbers*
A3185 A3187 A3188 A3189
Characteristic Min. Max. Min. Max. Min. Max. Min. Max.
B
OP
at TA = 25°C 170 270 50 150 100 180 50 230
over operating temp. range 140 300 50 175 80 200 50 250
B
RP
at TA = 25°C -270 -170 -150 -50 -180 -100 -230 -50
over operating temp. range -300 -140 -175 -50 -200 -80 -250 -50
B
hys
at TA = 25°C 340 540 100 300 200 360 100 460
over operating temp. range 280 600 100 350 160 400 100 500
FUNCTIONAL BLOCK DIAGRAM
NOTES: BOP = operate point (output turns ON); BRP = release point (output turns OFF); B
hys
= hysteresis (BOP - BRP). As used here, negative flux densities are defined as less than zero (algebraic convention). *Complete part number includes a suffix to identify operating temperature range (E or L) and package type ( LT, U, or UA).
V
CC
X
REG.
Dwg. FH-005-3
GROUND
OUTPUT
1
3
2
Copyright © 1995, 1999, Allegro MicroSystems, Inc.
3185
THRU
3189
HALL-EFFECT LATCHES
FOR HIGH-TEMPERATURE
OPERATION
TYPICAL OPERATING CHARACTERISTICS
A3185* SWITCH POINTS A3187* SWITCH POINTS
* Complete part number includes a suffix denoting operating temperature range (E or L) and package type (LT, U, or UA).
OUTPUT SATURATION VOLTAGE
SUPPLY CURRENT
SUPPLY CURRENT
OPERATE POINT
0 50 100
AMBIENT TEMPERATURE IN °C
-50
Dwg. GH-027
SWITCH POINT IN GAUSS
0
50
100
-50
-100
OPERATE POINT
RELEASE POINT
V = 12 V
CC
150
150
-150
-25 25 75 125
0 25 50 75
100
AMBIENT TEMPERATURE IN °C
-50
Dwg. GH-028
125
-25
V = 12 V
CC
B B
RP
SUPPLY CURRENT IN mA
7.0
6.0
5.0
4.0
B ≥ B
OP
150
0255075
100
300
0
AMBIENT TEMPERATURE IN °C
200
100
-50
Dwg. GH-029
SATURATION VOLTAGE IN mV
150
-25
125
I = 20 mA
V = 4.5–24 V
OUT
CC
10 15 20 25
SUPPLY VOLTAGE IN VOLTS
0
Dwg. GH-037
5
CHANGE IN OPERATE POINT IN GAUSS
-5.0
0
5.0
10
15
20
T = +25°C
A
0 50 100
AMBIENT TEMPERATURE IN °C
-50
Dwg. GH-026
SWITCH POINT IN GAUSS
0
100
200
-100
-200
OPERATE POINT
RELEASE POINT
V = 12 V
CC
150
300
-300
-25 25 75 125
10 15 20 25
SUPPLY VOLTAGE IN VOLTS
0
Dwg. GH-030
5
SUPPLY CURRENT IN mA
0
2.0
4.0
6.0
8.0
10
B B
OP
B B
RP
T = +25°C
A
3185
THRU
3189
HALL-EFFECT LATCHES FOR HIGH-TEMPERATURE OPERATION
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
SENSOR LOCATIONS
(±0.005” [0.13 mm] die placement)
Package Designators “LT”
1 32
Dwg. MH-008-4B
0.030"
0.76 mm NOM
ACTIVE AREA DEPTH
0.050"
1.27 mm
0.090"
2.27 mm
A
Package Designator “U”
1 32
Dwg. MH-002-7B
0.015"
0.38 mm NOM
BRANDED SURFACE
ACTIVE AREA DEPTH
0.077"
1.96 mm
0.092"
2.33 mm
A
Package Designators “UA” and "UA-TL"
1 32
Dwg. MH-011-4B
0.018"
0.46 mm NOM
BRANDED SURFACE
ACTIVE AREA DEPTH
0.083"
2.10 mm
0.060"
1.51 mm
A
The simplest form of magnet that will operate these devices is a ring
magnet, as shown below. Other methods of operation are possible.
Dwg. A-11,899
OPERATION
In operation, the output transistor is OFF until the strength of the mag­netic field perpendicular to the surface of the chip exceeds the threshold or operate point (BOP). When the field strength exceeds BOP, the output transis­tor switches ON and is capable of sinking 25 mA of current.
The output transistor switches OFF when magnetic field reversal results in a magnetic flux density below the OFF threshold (BRP). This is illustrated in the transfer characteristics graph (A3187* shown).
Note that the device latches; that is, a south pole of sufficient strength will turn the device ON. Removal of the south pole will leave the device ON. The presence of a north pole of sufficient strength is required to turn the device OFF.
APPLICATIONS INFORMATION
Extensive applications information on magnets and Hall-effect sensors is also available in the Allegro Integrated and Discrete Semiconductors Data Book or Application Note 27701.
30 V MAX
0+B
0
OUTPUT VOLTAGE IN VOLTS
FLUX DENSITY
Dwg. GH-034-4
-B
RP
B
V
OUT(SAT)
BB
V
OP
B
Although sensor location is accurate to three sigma for a particular design, product improve­ments may result in small changes to sensor location.
3185
THRU
3189
HALL-EFFECT LATCHES
FOR HIGH-TEMPERATURE
OPERATION
NOTES: 1. Tolerances on package height and width represent allowable mold offsets. Dimensions given are
measured at the widest point (parting line).
2. Exact body and lead configuration at vendor’s option within limits shown.
3. Height does not include mold gate flash.
4. Recommended minimum PWB hole diameter to clear transition area is 0.035" (0.89 mm).
5. Where no tolerance is specified, dimension is nominal.
6. Minimum lead length was 0.500" (12.70 mm). If existing product to the original specifications is not acceptable, contact sales office before ordering.
PACKAGE DESIGNATOR ‘U’
Dimensions in Inches
(controlling dimensions)
Dimensions in Millimeters
(for reference only)
Dwg. MH-003D in
0.063
0.059
0.018
0.015
0.016
0.050
1 2 3
0.100
45°
SEE NOTE
0.183
0.178
0.181
0.176
0.600
0.560
0.086
MAX
Dwg. MH-003D mm
1.60
1.50
0.46
0.38
0.41
1.27
1 2 3
2.54
45°
SEE NOTE
4.65
4.52
4.60
4.47
15.24
14.23
2.18
MAX
Devices in the ‘U’ package are
NOT RECOMMENDED FOR NEW DESIGN
3185
THRU
3189
HALL-EFFECT LATCHES FOR HIGH-TEMPERATURE OPERATION
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
Surface-Mount Lead Form (Suffix ‘-TL’)
NOTES: 1. Tolerances on package height and width represent allowable mold offsets. Dimensions given are
measured at the widest point (parting line).
2. Exact body and lead configuration at vendor’s option within limits shown.
3. Height does not include mold gate flash.
4. Recommended minimum PWB hole diameter to clear transition area is 0.035" (0.89 mm).
5. Where no tolerance is specified, dimension is nominal.
Dimensions in Inches
(controlling dimensions)
Dimensions in Millimeters
(for reference only)
PACKAGE DESIGNATOR ‘UA’
0.095
±0.005
0.020
MIN
FLAT
Dwg. MH-015 in
0.004
MAX
0.002
MAX
0°–8°
2.41
±0.13
0.51
MIN
FLAT
Dwg. MH-015 mm
0.10
MAX
0.051
MAX
0°–8°
Dwg. MH-014D mm
4.17
4.04
1.57
1.47
0.38
1.27
BSC
45°
16.26
15.24
0.41
2.16
MAX
45°
0.79
123
3.10
2.97
SEE NOTE
Dwg. MH-014D in
0.164
0.159
0.062
0.058
0.015
0.050
BSC
45°
0.640
0.600
0.016
0.085
MAX
45°
0.031
123
0.122
0.117
SEE NOTE
3185
THRU
3189
HALL-EFFECT LATCHES
FOR HIGH-TEMPERATURE
OPERATION
NOTE: Exact body and lead configuration at vendor’s option within limits shown.
PACKAGE DESIGNATOR ‘LT’
(SOT-89/TO-243AA)
Dimensions in Inches
(for reference only)
Dimensions in Millimeters
(controlling dimensions)
Dwg. MA-009-3 in
1
23
0.064
0.072
0.155
0.167
0.059
BSC
0.014
0.019
0.035
0.047
0.090
0.102
0.055
0.063
0.014
0.017
0.084
0.090
0.017
0.022
0.118
BSC
0.173
0.181
Dwg. MA-009-3 mm
1
23
4.40
4.60
1.62
1.83
3.94
4.25
1.50
BSC
0.36
0.48
0.89
1.20
2.29
2.60
1.40
1.60
0.35
0.44
2.13
2.29
0.44
0.56
3.00
BSC
Allegro MicroSystems, Inc. reserves the right to make, from time to time, such departures from the detail specifications as may be required to permit improvements in the design of its products.
The information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, Inc. assumes no responsi­bility for its use; nor for any infringements of patents or other rights of third parties which may result from its use.
3185
THRU
3189
HALL-EFFECT LATCHES FOR HIGH-TEMPERATURE OPERATION
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
HALL-EFFECT SENSORS SELECTION GUIDE
Partial Part Avail. Oper. Characteristics at TA = +25°C Number Temp. B
OP(max)BRP(min)
B
hys(typ)
Features Notes
HALL-EFFECT UNIPOLAR SWITCHES in order of B
OP
and B
hys
3240 E/L +50 +5.0 10 chopper stabilized 1 3210 E ±70 ±5.0 7.7 micropower, chopper stabilized 3361 E +120 +50 5.0* 2-wire, chopper stabilized 3362 E +120 +50 5.0* 2-wire, chopper stabilized 3161 E +160 +30 20 2-wire 3141 E/L +160 +10 55 3235 S +175 +25 15* output 1 2
-25 -175 15* output 2 2 5140 E +200 +50 55 300 mA output 1, 3 3142 E/L +230 +75 55 3143 E/L +340 +165 55 3144 E/L +350 +50 55 3122 E/L +400 +140 105 3123 E/L +440 +180 105 3121 E/L +450 +125 105 3150 J +40 to +850 20
programmable, chopper stabilized
1
HALL-EFFECT LATCHES & BIPOLAR SWITCHES† in order of B
OP
and B
hys
3260 E/L +30 -30 20 bipolar, chopper stabilized 3280 E/L +40 -40 45 chopper stabilized 3134 E/L +50 -50 27 bipolar switch 3133 K/L/S +75 -75 52 bipolar switch 3281 E/L +90 -90 100 chopper stabilized 3132 K/L/S +95 -95 52 bipolar switch 3187 E/L +150 -150 100* 3177 S +150 -150 200 3625 S +150 -150 200 900 mA outputs 1, 3, 5 3626 S +150 -150 200 400 mA outputs 1, 3, 5 3195 E/L +160 -160 220 1, 4 3197 L +160 -160 230 1 3175 S +170 -170 200 3188 E/L +180 -180 200* 3283 E/L +180 -180 300 chopper stabilized 3189 E/L +230 -230 100* 3275 S +250 -250 100* 5 3185 E/L +270 -270 340*
Operating Temperature Ranges:
S = -20°C to +85°C, E = -40°C to +85°C, J = -40°C to +115°C, K = -40°C to +125°C, L = -40°C to +150°C
Notes 1. Protected.
2. Output 1 switches on south pole, output 2 switches on north pole for 2-phase, bifilar-wound, unipolar-driven brushless dc motor control.
3. Power driver output.
4. Active pull down.
5. Complementary outputs for 2-phase bifilar-wound, unipolar-driven brushless dc motor control. * Minimum. Latches will not switch on removal of magnetic field; bipolar switches may switch on removal of field but require field reversal for reliable operation over operating temperature range.
Loading...