Datasheet A3134LUA, A3134LU, A3134LLT, A3134EUA, A3134EU Datasheet (Allegro)

...
Page 1
Always order by complete part number, e.g., A3134ELT .
FEATURES
Superior Temperature Stability
Operation From Unregulated Supply
Open-Collector 25 mA Output
Reverse Battery Protection
Activate With Small, Commercially Available Permanent Magnets
Solid-State Reliability
Resistant to Physical Stress
This low-hysteresis bipolar Hall-effect switch is an extremely temperature-stable and stress-resistant sensor especially suited for operation over extended temperature ranges to +150°C. Superior high-temperature performance is made possible through a novel Schmitt trigger circuit that maintains operate and release point stability by compensating for temperature changes in the Hall element. Additionally, internal compensation provides magnetic switch points that become more sensitive with temperature, hence offsetting the usual degradation of the magnetic field with temperature. Its low hysteresis makes this device ideal for detecting small changes in magnetic field strength or for use with inexpensive magnets.
The device includes on a single silicon chip a voltage regulator, quadratic Hall-voltage generator, temperature compensation circuit, signal amplifier, Schmitt trigger, and a buffered open-collector output to sink up to 25 mA. The on-board regulator permits operation with supply voltages of 3.8 volts to 24 volts.
The first character of the part number suffix determines the device operating temperature range. Suffix ‘E–’ is for -40°C to +85°C, and suffix ‘L–’ is -40°C to +150°C. Three package styles provide a magneti­cally optimized package for most applications. Suffix ‘–LT’ is a minia­ture SOT-89/TO-243AA transistor package for surface-mount applica­tions; suffix ‘–U’ is a three-lead plastic mini-SIP while suffix ‘–UA’ is a three-lead ultra-mini-SIP.
Pinning is shown viewed from branded side.
ABSOLUTE MAXIMUM RATINGS
at TA = +25°C
Supply Voltage, VCC............................. 30 V
Reverse Battery Voltage, V
RCC
.......... -30 V
Magnetic Flux Density, B .......... Unlimited
Output OFF Voltage, V
OUT
.................. 30 V
Reverse Output Voltage, V
OUT
........... -0.5 V
Continuous Output Current,
I
OUT
............................................ 25 mA
Operating Temperature Range, T
A
Suffix ‘E–’ .................. -40°C to +85°C
Suffix ‘L–’ ................ -40°C to +150°C
Storage Temperature Range,
TS.............................. -65°C to +170°C
Data Sheet
27631.4B
3134
BIPOLAR HALL-EFFECT SWITCH
FOR HIGH-TEMPERATURE OPERATION
Dwg. PH-003A
1
SUPPLY
V
CC
GROUND
32
OUTPUT
X
Page 2
3134
LOW-HYSTERESIS BIPOLAR HALL-EFFECT SWITCH FOR HIGH-TEMP. OPERATION
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
Limits
Characteristic Symbol Test Conditions Min. Typ. Max. Units
Supply Voltage V
CC
Operating 3.8 24 V
Output Saturation Voltage V
OUT(SAT)
I
OUT
= 20 mA, B > B
OP
175 400 mV
Output Leakage Current I
OFF
V
OUT
= 24 V, B < B
RP
0.05 1.0 µA
Supply Current I
CC
B < BRP (Output OFF) 3.2 9.0 mA
B > BOP (Output ON) 5.0 mA
Output Rise Time t
r
RL = 820 , CL = 20 pF 100 ns
Output Fall Time t
f
RL = 820 , CL = 20 pF 100 ns
ELECTRICAL CHARACTERISTICS over operating temperature range, at V
CC
= 12 V.
MAGNETIC CHARACTERISTICS over operating supply voltage range.
V
CC
X
REG.
Dwg. FH-005-3
GROUND
OUTPUT
1
3
2
FUNCTIONAL BLOCK DIAGRAM
Limits
Characteristic Symbol Test Conditions Min. Typ. Max. Units
Operate Point B
OP
at TA = +25°C-408.550G
Over Oper. Temp. Range -40 50 G
Release Point B
RP
at TA = +25°C-50-1940G
Over Oper. Temp. Range -50 40 G
Hysteresis B
hys
at TA = +25°C 102750 G
Over Oper. Temp. Range 5.0 55 G
Copyright © 1995, 1999, Allegro MicroSystems, Inc.
NOTES: BOP = operate point (output turns ON); BRP = release point (output turns OFF); B
hys
= hysteresis (BOP - BRP). As used here, negative flux densities are defined as less than zero (algebraic convention). Typical values are at TA = +25°C and VCC = 12 V.
Page 3
3134
LOW-HYSTERESIS
BIPOLAR HALL-EFFECT SWITCH
FOR HIGH-TEMP. OPERATION
TYPICAL OPERATING CHARACTERISTICS
0 25 50 75
100
AMBIENT TEMPERATURE IN °C
-50
Dwg. GH-053
125-25
SUPPLY CURRENT IN mA
5.0
4.0
3.0
2.0
1.0 150
V = 12 V
CC
B < B
RP
V = 24 V
CC
V = 4.5 V
CC
OUTPUT SATURATION VOLTAGE SUPPLY CURRENT
0 25 50 75
100
AMBIENT TEMPERATURE IN °C
-50
Dwg. GH-052
125-25
SWITCH POINT IN GAUSS
40
20
0
-20
-40
RELEASE POINT
OPERATE POINT
150
CC
V = 4.5 V–24 V
SWITCH POINTS HYSTERESIS
0 25 50 75
100
AMBIENT TEMPERATURE IN °C
-50
Dwg. GH-051
125-25
HYSTERESIS IN GAUSS
20
10
0
150
30
CC
V = 4.5 V–24 V
40
50
0255075
100
300
0
AMBIENT TEMPERATURE IN °C
200
100
-50
Dwg. GH-029
SATURATION VOLTAGE IN mV
150
-25
125
I = 20 mA
V = 4.5–24 V
OUT
CC
Page 4
3134
LOW-HYSTERESIS BIPOLAR HALL-EFFECT SWITCH FOR HIGH-TEMP. OPERATION
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
APPLICATIONS INFORMATION
Hall effect applications information is available in the “Hall-Effect IC Applications Guide” (AN 27701), which can be found in the latest issue of Allegro MicroSystems Electronic Data Book, AMS-702, or at
www.allegromicro.com
OPERATION
The output of these devices (pin 3) switches low when the magnetic field at the Hall sensor exceeds the operate point threshold (BOP). At this point, the output voltage is V
OUT(SAT)
. When the magnetic field is reduced to below the release point (BRP) the device output goes high. Note especially that release can occur when the magnetic field is removed but to ensure release, a field reversal is required. The difference in the magnetic operate and release points is called the hysteresis (B
hys
) of the device. This built-in hysteresis allows clean switching of the output even in the presence of external mechanical vibration and electrical noise.
Suffix “UA”
SENSOR LOCATIONS
(±0.005" [0.13 mm] die placement)
1 32
Dwg. MH-011-4B
0.018"
0.46 mm NOM
BRANDED SURFACE
ACTIVE AREA DEPTH
0.083"
2.10 mm
0.060"
1.51 mm
A
Suffix “U”
1 32
Dwg. MH-002-7B
0.015"
0.38 mm NOM
BRANDED SURFACE
ACTIVE AREA DEPTH
0.077"
1.96 mm
0.092"
2.33 mm
A
Suffix “LT”
1 32
Dwg. MH-008-4B
0.030"
0.76 mm NOM
ACTIVE AREA DEPTH
0.050"
1.27 mm
0.090"
2.27 mm
A
Page 5
3134
LOW-HYSTERESIS
BIPOLAR HALL-EFFECT SWITCH
FOR HIGH-TEMP. OPERATION
Dimensions in Millimeters
(controlling dimensions)
Dwg. MA-009-3 in
1
23
0.064
0.072
0.155
0.167
0.059
BSC
0.014
0.019
0.035
0.047
0.090
0.102
0.055
0.063
0.014
0.017
0.084
0.090
0.017
0.022
0.118
BSC
0.173
0.181
PACKAGE DESIGNATOR ‘LT’
(SOT-89/TO-243AA)
Dimensions in Inches
(for reference only)
Dwg. MA-009-3 mm
1
23
4.40
4.60
1.62
1.83
3.94
4.25
1.50
BSC
0.36
0.48
0.89
1.20
2.29
2.60
1.40
1.60
0.35
0.44
2.13
2.29
0.44
0.56
3.00
BSC
NOTES: 1. Tolerances on package height and width represent allowable mold offsets.
Dimensions given are measured at the widest point (parting line).
2. Exact body and lead configuration at vendor’s option within limits shown.
3. Height does not include mold gate flash.
Page 6
3134
LOW-HYSTERESIS BIPOLAR HALL-EFFECT SWITCH FOR HIGH-TEMP. OPERATION
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
Dwg. MH-003D mm
1.60
1.50
0.46
0.38
0.41
1.27
1 2 3
2.54
45°
SEE NOTE
4.65
4.52
4.60
4.47
15.24
14.23
2.18
MAX
Dwg. MH-003D in
0.063
0.059
0.018
0.015
0.016
0.050
1 2 3
0.100
45°
SEE NOTE
0.183
0.178
0.181
0.176
0.600
0.560
0.086
MAX
PACKAGE DESIGNATOR ‘U’
Dimensions in Inches
(controlling dimensions)
Dimensions in Millimeters
(for reference only)
Devices in the ‘U’ package are
NOT RECOMMENDED FOR NEW DESIGN
NOTES: 1. Tolerances on package height and width represent allowable mold offsets.
Dimensions given are measured at the widest point (parting line).
2. Exact body and lead configuration at vendor’s option within limits shown.
3. Height does not include mold gate flash.
4. Recommended minimum PWB hole diameter to clear transition area is 0.035" (0.89 mm).
5. Where no tolerance is specified, dimension is nominal.
Page 7
3134
LOW-HYSTERESIS
BIPOLAR HALL-EFFECT SWITCH
FOR HIGH-TEMP. OPERATION
Dwg. MH-014D in
0.164
0.159
0.062
0.058
0.015
0.050
BSC
45°
0.640
0.600
0.016
0.085
MAX
45°
0.031
123
0.122
0.117
SEE NOTE
PACKAGE DESIGNATOR ‘UA’
Dimensions in Inches
(controlling dimensions)
Dimensions in Millimeters
(for reference only)
Dwg. MH-014D mm
4.17
4.04
1.57
1.47
0.38
1.27
BSC
45°
16.26
15.24
0.41
2.16
MAX
45°
0.79
123
3.10
2.97
SEE NOTE
Allegro MicroSystems, Inc. reserves the right to make, from time to time, such departures from the detail specifications as may be required to permit improvements in the design of its products.
The information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, Inc. assumes no responsibility for its use; nor for any infringements of patents or other rights of third parties which may result from its use.
NOTES: 1. Tolerances on package height and width represent allowable mold offsets.
Dimensions given are measured at the widest point (parting line).
2. Exact body and lead configuration at vendor’s option within limits shown.
3. Height does not include mold gate flash.
4. Recommended minimum PWB hole diameter to clear transition area is 0.035" (0.89 mm).
5. Where no tolerance is specified, dimension is nominal.
Page 8
3134
LOW-HYSTERESIS BIPOLAR HALL-EFFECT SWITCH FOR HIGH-TEMP. OPERATION
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
HALL-EFFECT SENSORS SELECTION GUIDE
Partial Part Avail. Oper. Characteristics at TA = +25°C Number Temp. B
OP(max)BRP(min)
B
hys(typ)
Features Notes
HALL-EFFECT UNIPOLAR SWITCHES in order of B
OP
and B
hys
3240 E/L +50 +5.0 10 chopper stabilized 1 3210 E ±70 ±5.0 7.7 micropower, chopper stabilized 3361 E +120 +50 5.0* 2-wire, chopper stabilized 3362 E +120 +50 5.0* 2-wire, chopper stabilized 3161 E +160 +30 20 2-wire 3141 E/L +160 +10 55 3235 S +175 +25 15* output 1 2
-25 -175 15* output 2 2 5140 E +200 +50 55 300 mA output 1, 3 3142 E/L +230 +75 55 3143 E/L +340 +165 55 3144 E/L +350 +50 55 3122 E/L +400 +140 105 3123 E/L +440 +180 105 3121 E/L +450 +125 105 3150 J +40 to +850 20
programmable, chopper stabilized
1
HALL-EFFECT LATCHES & BIPOLAR SWITCHES† in order of B
OP
and B
hys
3260 E/L +30 -30 20 bipolar, chopper stabilized 3280 E/L +40 -40 45 chopper stabilized 3134 E/L +50 -50 27 bipolar switch 3133 K/L/S +75 -75 52 bipolar switch 3281 E/L +90 -90 100 chopper stabilized 3132 K/L/S +95 -95 52 bipolar switch 3187 E/L +150 -150 100* 3177 S +150 -150 200 3625 S +150 -150 200 900 mA outputs 1, 3, 5 3626 S +150 -150 200 400 mA outputs 1, 3, 5 3195 E/L +160 -160 220 1, 4 3197 L +160 -160 230 1 3175 S +170 -170 200 3188 E/L +180 -180 200* 3283 E/L +180 -180 300 chopper stabilized 3189 E/L +230 -230 100* 3275 S +250 -250 100* 5 3185 E/L +270 -270 340*
Operating Temperature Ranges:
S = -20°C to +85°C, E = -40°C to +85°C, J = -40°C to +115°C, K = -40°C to +125°C, L = -40°C to +150°C
Notes 1. Protected.
2. Output 1 switches on south pole, output 2 switches on north pole for 2-phase, bifilar-wound, unipolar-driven brushless dc motor control.
3. Power driver output.
4. Active pull down.
5. Complementary outputs for 2-phase bifilar-wound, unipolar-driven brushless dc motor control. *Minimum. Latches will not switch on removal of magnetic field; bipolar switches may switch on removal of field but require field reversal for reliable operation over operating temperature range.
Loading...