September 1993 6
Philips Semiconductors Product specification
16-channel analog
multiplexer/demultiplexer
74HC/HCT4067
RATINGS
Limiting values in accordance with the Absolute Maximum System (IEC 134)
Voltages are referenced to GND (ground = 0 V)
Note
1. To avoid drawing V
CC
current out of terminal Z, when switch current flows in terminals Yn, the voltage drop across
the bidirectional switch must not exceed 0.4 V. If the switch current flows into terminal Z, no VCCcurrent will flow out
of terminals Yn. In this case there is no limit for the voltage drop across the switch, but the voltages at Ynand Z may
not exceed VCCor GND.
RECOMMENDED OPERATING CONDITIONS
SYMBOL PARAMETER MIN. MAX. UNIT CONDITIONS
V
CC
DC supply voltage −0.5 +11.0 V
±I
IK
DC digital input diode current 20 mA for VI<−0.5 or VI> VCC+ 0.5 V
±I
SK
DC switch diode current 20 mA for VS<−0.5 or VS> VCC+ 0.5 V
±I
S
DC switch current 25 mA for −0.5 V < VS< VCC+ 0.5 V
±I
CC
; ±I
GND
DC VCCor GND current 50 mA
T
stg
storage temperature range −65 +150 °C
P
tot
power dissipation per package for temperature range: −40 to +125 °C
74HC/HCT
plastic DIL 750 mW above +70 °C: derate linearly with 12 mW/K
plastic mini-pack (SO) 500 mW above +70 °C: derate linearly with 8 mW/K
P
S
power dissipation per switch 100 mW
SYMBOL PARAMETER
74HC 74HCT
UNIT CONDITIONS
min. typ. max. min. typ. max.
V
CC
DC supply voltage 2.0 5.0 10.0 4.5 5.0 5.5 V
V
I
DC input voltage range GND V
CC
GND V
CC
V
V
S
DC switch voltage range GND V
CC
GND V
CC
V
T
amb
operating ambient temperature range −40 +85 −40 +85 °C see DC and AC
CHARACTERISTICS
T
amb
operating ambient temperature range −40 +125 −40 +125 °C
tr,t
f
input rise and fall times
6.0
1000
500
400
250
6.0 500 ns
VCC= 2.0 V
VCC= 4.5 V
VCC= 6.0 V
VCC= 10.0 V