AC Electrical Characteristics
54AC
V
CC
T
A
=
−55˚C
Symbol Parameter (V) to +125˚C Units
(Note 8) C
L
=
50 pF
Min Max
f
max
Maximum Clock 3.3 55 MHz
Frequency 5.0 90
t
PLH
Propagation Delay, CP to Q
n
3.3 1.0 13.5 ns
(PE Input HIGH or LOW)
5.0 1.5 9.5
t
PHL
Propagation Delay, CP to Q
n
3.3 1.0 12.5 ns
(PE Input HIGH or LOW)
5.0 1.5 9.5
t
PLH
Propagation Delay 3.3 1.0 16.5 ns
CP to TC 5.0 1.5 11.0
t
PHL
Propagation Delay 3.3 1.0 15.0 ns
CP to TC 5.0 1.5 11.0
t
PLH
Propagation Delay 3.3 1.0 11.0 ns
CET to TC 5.0 1.5 7.5
t
PHL
Propagation Delay 3.3 1.0 12.0 ns
CET to TC 5.0 1.5 9.0
Note 8: Voltage Range 3.3 is 3.3V±0.3V
Voltage Range 5.0 is 5.0V
±
0.5V
AC Operating Requirements
54AC
V
CC
T
A
=
−55˚C
Symbol Parameter (V) to +125˚C Units
(Note 9) C
L
=
50 pF
Guaranteed Minimum
t
s
Setup Time, HIGH or LOW 3.3 17.0 ns
P
n
to CP 5.0 11.0
t
h
Hold Time, HIGH or LOW 3.3 −0.5 ns
P
n
to CP 5.0 0
t
s
Setup Time, HIGH or LOW 3.3 17.0 ns
SR to CP
5.0 12.0
t
h
Hold Time, HIGH or LOW 3.3 −0.5 ns
SR to CP
5.0 0
t
s
Setup Time, HIGH or LOW 3.3 16.0 ns
PE to CP
5.0 9.5
t
h
Hold Time, HIGH or LOW 3.3 −0.5 ns
PE to CP
5.0 0
t
s
Setup Time, HIGH or LOW 3.3 8.0 ns
CEP or CET to CP 5.0 5.5
t
h
Hold Time, HIGH or LOW 3.3 0 ns
CEP or CET to CP 5.0 0.5
t
w
Clock Pulse Width (Load) 3.3 5.0 ns
HIGH or LOW 5.0 5.0
t
w
Clock Pulse Width (Count) 3.3 5.0 ns
HIGH or LOW 5.0 5.0
Note 9: Voltage Range 3.3 is 3.3V±0.3V
Voltage Range 5.0 is 5.0V
±
0.5V
www.national.com7