3.3V ABT Octal Bus Transceiver
with 3-State Output
Memory
Logic Diagram (Positive Logic)
FEATURES:
• 3.3V ABT octal bus transceiver with 3-state outputs
•R
AD-PAK® radiation hardened against natural space radia-
tion
• Total dose hardness:
- >100 krad (Si), depending upon space misssion
• Package:
- 20 pin R
- 20 pin R
• Operating temperature range:
-55 to 125
• Supports mixed-mode signal operation
- 5V input and output voltages with 3.3V V
• Supports unregulated battery operation down to 2.7V.
• Typical VOLP (output ground bounce) < 0.8V at V
T
A
• Latch-up performance exceeds 500mA per JEDEC standard
• Supports live insertion
• Bus-hold data inputs eliminate the need for external pullup
resistors
AD-PAK® flat package
AD-PAK® DIP
°
C
= 25°C
CC
=3.3V,
CC
DESCRIPTION:
Maxwell Technologies’ 54LVTH245A 8-bit octal transceiver
micro-circuit features a greater than 100 krad (Si) total dose
tolerance, depending upon space mission. The 54LVTH245A
is designed specifically for low voltage (3.3V) V
but with the capability to provide a TTL interface to a 5V system environment. It is designed for asynchronous communication between data buses. The device transmits data from the
A bus to the B bus or from the B bus to the A bus depending
upon the logic level at the direction control (DIR) input. The
output enable (OE
the buses are effectively isolated. The 54LVTH245A active
bus-hold circuitry is provided to prevent floating data inputs at
a valid logic level and to eliminate the need for external pullup
resistors.
Maxwell Technologies' patented R
ogy incorporates radiation shielding in the microcircuit package. It eliminates the need for box shielding while providing
the required radiation shielding for a lifetime in orbit or space
mission. In a GEO orbit, R
krad (Si) radiation dose tolerance. This product is available
with screening up to Class S.
Voltage Range Applied to Any Output in the High State or Power-Off
CC
V
I
V
O
1
-0.54.6V
-0.57.0V
-0.57.0V
State
Current Into Any Output in the High State
Input Clamp Current (V
Output Clamp Current (V
Maximum Power Dissipation at T
< 0)I
I
< 0)I
O
A
3
= 55°CP
Operating TemperatureT
Storage Temperature RangeT
I
OK
O
IK
D
A
S
--48mA
---50mA
---50mA
--1.6mW
-55125°C
-65150
°
C
1. Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are
stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may
affect device reliability.
2. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
3. This current flows only when the output is in the high state and VO > VCC.
Memory
1000597
TABLE 3. DELTA LIMITS
PARAMETERVARIATION
I
CC(OL)
I
CC(OH)
I
CC(OD)
±10% of specified value in Table 5
±10% of specified value in Table 5
±10% of specified value in Table 5
12.19.01 Rev 1
All data sheets are subject to change without notice
FIGURE 4. PROPAGATION DELAY TIMES INVERTINGAND NONINVERTING OUTPUTS
PRELIMINARY
FIGURE 5. ENABLEAND DISABLE TIMES LOW- AND HIGH-LEVEL ENABLING
54LVTH245A
Memory
Figure Note:
2. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by
The output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by
the output control.
1000597
12.19.01 Rev 1
All data sheets are subject to change without notice
These data sheets are created using the chip manufacturer’s published specifications. Maxwell Technologies verifies
PRELIMINARY
functionality by testing key parameters either by 100% testing, sample testing or characterization.
The specifications presented within these data sheets represent the latest and most accurate information available to
date. However, these specifications are subject to change without notice and Maxwell Technologies assumes no
responsibility for the use of this information.
Maxwell Technologies’ products are not authorized for use as critical components in life support devices or systems
without express written approval from Maxwell Technologies.
Any claim against Maxwell Technologies must be made within 90 days from the date of shipment from Maxwell Technologies. Maxwell Technologies’ liability shall be limited to replacement of defective parts.
Memory
1000597
12.19.01 Rev 1
All data sheets are subject to change without notice