DC Characteristics for ’ACTQ Family Devices (Continued)
54ACTQ
Symbol Parameter V
CC
T
A
=
Units Conditions
(V) −55˚C to
+125˚C
Guaranteed
Limits
I
OLD
Minimum Dynamic 5.5 50 mA V
OLD
=
1.65V Max
I
OHD
Output Current
(Note 4)
5.5 −50 mA V
OHD
=
3.85V Min
I
CC
Maximum Quiescent 5.5 80.0 µA V
IN
=
V
CC
Supply Current or GND (Note 5)
V
OLP
Quiet Output 5.0 1.7 V (Notes 6, 7)
Maximum Dynamic V
OL
V
OLV
Quiet Output 5.0 −1.2 V (Notes 6, 7)
Minimum Dynamic V
OL
Note 3: All outputs loaded; thresholds on input associated with output under test.
Note 4: Maximum test duration 2.0 ms, one output loaded at a time.
Note 5: I
CC
for 54ACTQ@25˚C is identical to 74ACQ@25˚C.
Note 6: Plastic DIP package.
Note 7: Max number of outputs defined as (n). Data inputs are driven 0V to 3V. One output
@
GND.
AC Electrical Characteristics
54ACTQ
V
CC
T
A
=
−55˚C Fig.
Symbol Parameter (V) to +125˚C Units No.
(Note 8) C
L
=
50 pF
Min Max
t
PHL,tPLH
Propagation Delay 5.0 1.5 9.0 ns
D
n
to O
n
t
PHL,tPLH
Propagation Delay 5.0 1.5 10.5 ns
LE to O
n
t
PZL,tPZH
Output Enable Time 5.0 1.5 10.5 ns
t
PHZ,tPLZ
Output Disable Time 5.0 1.5 10.5 ns
Note 8: Voltage Range 5.0 is 5.0V±0.5V.
Note 9: Skewis defined as the absolute value of the difference between the actual propagation delay for any two separate outputs of the same device. The speci-
fication applies to any outputs switching in the same direction, either HIGH to LOW (t
OSHL
) or LOW to HIGH (t
OSLH
). Parameter guaranteed by design.
AC Operating Requirements
54ACTQ
V
CC
T
A
=
−55˚C Fig.
Symbol Parameter (V) to +125˚C Units No.
(Note 10) C
L
=
50 pF
Guaranteed
Minimum
t
S
Setup Time, HIGH or LOW 5.0 3.0 ns
D
n
to LE
t
H
Hold Time, HIGH or LOW 5.0 1.5 ns
D
n
to LE
t
W
LE Pulse Width, HIGH 5.0 5.0 ns
Note 10: Voltage Range 5.0 is 5.0V±0.5V.
www.national.com 4