These Hall-effect switches are designed for magnetic actuation using
a bipolar magnetic field, i.e., a north-south alternating field. They
combine extreme magnetic sensitivity with excellent stability over
varying temperature and supply voltage. The high sensitivity permits
their use with multi-pole ring magnets over relatively large distances.
Each device includes a voltage regulator, quadratic Hall voltage
generator, temperature stability circuit, signal amplifier, Schmitt trigger,
and open-collector output on a single silicon chip. The on-board regulator permits operation with supply voltages of 4.5 to 24 V. The switch
output can sink up to 25 mA. With suitable output pull up, they can be
used directly with bipolar or MOS logic circuits.
Data Sheet
27631.2B
1
SUPPLY
Pinning is shown viewed from branded side.
ABSOLUTE MAXIMUM RATINGS
Supply Voltage, VCC. . . . . . . . . . . . . 25 V
Reverse Battery Voltage, V
Magnetic Flux Density, B . . . . Unlimited
Output OFF Voltage, V
Continuous Output Current, I
Operating Temperature Range, T
Prefix UGL . . . . . . . -40°C to +150°C
Prefix UGN . . . . . . . . -20°C to +85°C
Prefix UGS . . . . . . . -40°C to +125°C
Storage Temperature Range,
TS. . . . . . . . . . . . . . . -65°C to +150°C
GROUND
OUT
32
OUTPUT
Dwg. PH-003A
. . . . -35 V
RCC
. . . . . . . . 25 V
. 25 mA
OUT
A
The three package styles available provide a magnetically optimized
package for most applications. Suffix ‘LT’ is a miniature SOT-89/TO243AA transistor package for surface-mount applications; suffixes ‘U’,
and ‘UA’ feature wire leads for through-hole mounting. Prefix ‘UGN’
devices are rated for continuous operation over the temperature range of
-20°C to +85°C, prefix ‘UGS’ devices over an extended range of -40°C
to +125°C, and prefix ‘UGL’ devices over the range of -40°C to +150°C.
NOTES: 1. Tolerances on package height and width represent
allowable mold offsets. Dimensions given are measured at the
widest point (parting line).
2. Exact body and lead configuration at vendor’s option
within limits shown.
3. Height does not include mold gate flash.
4. Recommended minimum PWB hole diameter to clear
transition area is 0.035" (0.89 mm).
5. Where no tolerance is specified, dimension is nominal.
SEE NOTE
1.27
BSC
0.48
0.36
Dwg. MH-014E mm
The products described herein are manufactured under one or
more of the following U.S. patents: 5,045,920; 5,264,783; 5,442,283;
5,389,889; 5,581,179; 5,517,112; 5,619,137; 5,621,319; 5,650,719;
5,686,894; 5,694,038; 5,729,130; 5,917,320; and other patents
pending.
Allegro MicroSystems, Inc. reserves the right to make, from time to
time, such departures from the detail specifications as may be
required to permit improvements in the performance, reliability, or
manufacturability of its products. Before placing an order, the user is
cautioned to verify that the information being relied upon is current.
Allegro products are not authorized for use as critical components
in life-support appliances, devices, or systems without express written
approval.
The information included herein is believed to be accurate and
reliable. However, Allegro MicroSystems, Inc. assumes no responsibility for its use; nor for any infringements of patents or other rights of
third parties that may result from its use.
www.allegromicro.com
Page 8
3132
AND
3133
BIPOLAR
HALL-EFFECT SWITCHES
HALL-EFFECT SENSORS SELECTION GUIDE
Partial PartAvail. Oper.Characteristics at TA = +25°C
NumberTemp.B
S = -20°C to +85°C, E = -40°C to +85°C, J = -40°C to +115°C, K = -40°C to +125°C, L = -40°C to +150°C
Notes 1. Protected.
2. Output 1 switches on south pole, output 2 switches on north pole for 2-phase, bifilar-wound, unipolar-driven brushless dc
motor control.
3. Power driver output.
4. Active pull down.
5. Complementary outputs for 2-phase bifilar-wound, unipolar-driven brushless dc motor control.
* Minimum.
† Latches will not switch on removal of magnetic field; bipolar switches may switch on removal of field but require field reversal
for reliable operation over operating temperature range.