Datasheet 2455RC, 2455R Specification

Page 1
Thermostats - Commercial
THERMOST ATS - COMMERCIAL
Commercial thermostats include products for use in a wide array of small and major appliances, automotive applications, office copy machines, heat and smoke detectors and HVAC equipment. These snap-action thermostats include automatic or manual reset options, phenolic or ceramic housings, and a variety of mounting brackets and terminal options.
NOTE: The products in this section do not follow the “how to use this catalogue” instructions provided in the catalogue introduction. Specific reference numbers are not given due to their custom nature. Please contact your local Honeywell sales office for ordering information.
2450R/2450HR/2455R Series Phenolic Automatic Reset Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. Response to temperature changes is extremely rapid due to the inherently low mass of the disc and the small size of the product. These products are factory calibrated to the customer’s specification.
Reset type: Automatic Amperage capacity: 15 A resistive max. Housing material: Phenolic Operating temperature range: 0 °C to 150 °C [32 °F to 302 °F] Environmental exposure range: 0 °C to 177 °C [32 °F to 350 °F]
2450R
14,43 DIA. [0.568]
16,0 DIA. [0.630]
0,51 [0.020]
9,63
[0.379]
2450HR
14,43 DIA. [0.568]
16,0 DIA. [0.630]
SERIES NAME
2450HR Phenolic Automatic Reset Thermostat
2455R
14,43 DIA. [0.568]
16,0 DIA. [0.630]
6,73 [0.265]
2,36 [0.093] DIA. 1,57 [0.062] DEEP
[0.486]
9,12
[0.359]
0,51 [0.020]
12,34
13,94
[0.549]
11,91 [0.469]
SERIES NAME
2450R Phenolic Automatic Reset Thermostat
SERIES NAME
2455R Phenolic Automatic Reset Thermostat
www.honeywell.com/sensing
27
Page 2
THERMOSTATS - COMMERCIAL
2450RC/2450RCH/2455RC Series Ceramic Automatic Reset Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. Response to temperature changes is extremely rapid due to the inherently low mass of the disc and the small size of the product.
Reset type: Automatic Amperage capacity: 15 A resistive max. Housing material: Ceramic Operating temperature range: 0 °C to 260 °C [32 °F to 500 °F] Environmental exposure range: –20 °C to 287 °C [0 °F to 550 °F]
2450RC
16,00
[0.379]
9,63
[0.379]
0,51 [0.020]
SERIES NAME
2450RC Ceramic Automatic Reset Thermostat
2450CM/2455RM Series Ceramic and Phenolic Manual Reset Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. The circuit will stay open above room ambient temperature until the manual reset button is pressed. Response to temperature changes is extremely rapid due to the inherently low mass of the disc and the small size of the product.
Reset type: Manual Amperage capacity: 15 A resistive max. Housing material: Ceramic or phenolic Operating temperature range: 52 °C to 232 °C [125 °F to 450 °F] (ceramic)
Environmental exposure range: 10 °C to 260 °C [50 °F to 500 °F] (ceramic)
2450CM
14,43 DIA.
[0.568]
52 °C to 150 °C [125 °F to 302 °F] (phenolic)
10 °C to 177 °C [50 °F to 350 °F] (phenolic)
1,04 [0.041] MAX TRAVEL OF RESET BUTTON ON CONTACT OPENING
14,48
12,90
[0.570]
[0.508]
9,55
9,04
[0.376]
[0.356]
16,0 DIA. [0.630]
0,51 [0.020]
15,98
[0.629]
2450RCH
14,43 DIA. [0.568]
16,0 DIA. [0.630]
SERIES NAME
2450RCH Ceramic Automatic Reset Thermostat
2455RC
14,43 DIA. [0.568]
16,0 DIA. [0.630]
SERIES NAME
2455RC Ceramic Automatic Reset Thermostat
2,36 [0.093] DIA. 1,57 [0.062] DEEP
9,04
[0.356]
ENCLOSED DISK
0,51 [0.020]
12,90
[0.508]
11,91 [0.469]
14,48
[0.570]
SERIES NAME
2450CM Ceramic Manual Reset Thermostat
2455RM
2,77 DIA. RESET [0.109] BUTTON
14,43 DIA. [0.568]
16,0 DIA. [0.630]
SERIES NAME
2455RM Phenolic Manual Reset Thermostat
1,04 [0.041] MAX TRAVEL OF RESET BUTTON ON CONTACT OPENING
15,88 ON CONTACT [0.625] CLOSING
11,91 [0.469]
0,51
[0.020]
28
www.honeywell.com/sensing
Page 3
THERMOSTATS - COMMERCIAL
2450A/2455A Series Heat Detection Thermostats
The gold contacts open or close on a temperature rise of 47 °C to 107 °C
°
F to 225 °F].
[117
Reset type: Automatic Amperage capacity: 15 A resistive max. Housing material: Phenolic, epoxy-sealed cap and terminal Operating temperature range: 47 Environmental exposure range: 0 °C to 150 °C [32 °F to 302 ° F]
2450A
SERIES NAME
2450A Heat Detection Thermostat
2455A
SERIES NAME
2455A Heat Detection Thermostat
°
C to 107 °C [117 °F to 225 °F]
9,63
[0.379]
0,51 [0.020]
11,91 [0.469]
0,51 [0.020]
2450R/2450RCH/2455R/2455RC Series “One-shot” ½ in Thermostats
Products are designed for high limit applications where automatic reset is not desired.
Reset type: None Amperage capacity: 15 A resistive max. Housing material: ceramic or phenolic Operating temperature range: 52
Environmental exposure range: 18 °C to 316 °C [0 °F to 600 °F] (ceramic)
2450R
14,43 DIA. [0.568]
SERIES NAME
2450R Phenolic “One-shot” ½ in Thermostat
2450RCH
14,43 DIA. [0.568]
°
C to 260 °C [125 °F to 500 °F] (ceramic)
52 °C to 150 °C [125 °F to 302 °F] (phenolic)
18 °C to 177 °C [0 °F to 350 °F] (phenolic)
9,63
[0.379]
16,0 DIA. [0.630]
2,36 [0.093] DIA. 1,57 [0.062] DEEP
0,51 [0.020]
9,04
[0.356]
12,90
[0.508]
14,48
[0.570]
2455RBV Series Overmolded Automatic Reset Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. Response to temperature changes is extremely rapid due to the inherently low mass of the disc and the small size of the product.
Reset type: Automatic Amperage capacity: 15 A resistive max. Housing material: Ceramic or phenolic, epoxy overmold Operating temperature range: -12 °C to 105 °C [10 °F to 221 °F] Environmental exposure range: -18 °C to 121 °C [0 °F to 250 °F]
2455RBV
WIRE GAGE AND
INSULATION AS
REQUIRED
17,27 DIA. [0.680]
AS REQUIRED
AS REQUIRED
18,54 [0.730]
0,51
[0.020]
16,0 DIA. [0.630]
SERIES NAME
2450RCH Ceramic “One-shot” ½ in Thermostat
2455R
14,43 DIA. [0.568]
16,0 DIA. [0.630]
SERIES NAME
2455R Phenolic “One-shot” ½ in Thermostat
2455RC
14,43 DIA. [0.568]
16,0 DIA. [0.630]
ENCLOSED DISK
11,91 [0.469]
0,51 [0.020]
11,91 [0.469]
0,51 [0.020]
SERIES NAME
2455RBV Overmolded Automatic Reset Thermostat
SERIES NAME
2455RC Ceramic “One-shot” ½ in Thermostat
www.honeywell.com/sensing
29
Page 4
THERMOSTATS - COMMERCIAL
2450R Series Annular Ring Cap Automatic Reset Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. Response to temperature changes is extremely rapid due to the inherently low mass of the disc and the small size of the product.
Reset type: Automatic Amperage capacity: 15 A resistive, 12 Vdc Housing material: Phenolic, can be partially or totally sealed
Operating temperature range: -10 Environmental exposure range: -40 °C to 130 °C [-40 °F to 266 °F] Life Cycle Capability: 300 K at 12 Vdc, 10 A Low Temperature Differential: Down to 8 °C [46 °F] Switch Temperature Tolerance: ±3 °C
14,43 DIA. [0.568]
16,0 DIA. [0.630]
against water ingress
°
C to 55 °C [14 °F to 131 °F]
9,63
[0.379]
0,51 [0.020]
2450R Series Fully Sealed Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. Response to temperature changes is extremely rapid due to the inherently low mass of the disc and the small size of the product.
Reset type: Automatic Amperage capacity: 15 A resistive, 12 Vdc Housing material: Phenolic housing, aluminium cap totally
Operating temperature range: -10 Environmental exposure range: -40 °C to 130 °C [-40 °F to 266 °F] Life cycle capability: 300 K at 12 Vdc, 10 A Low temperature differential: Down to 8 °C [46 °F] Switch temperature tolerance: ±3 °C
16,1 MAX. [0.63]
encapsulated in water resistant epoxy
°
C to 55 °C [14 °F to 131 °F]
11,5
[0.45]
SERIES NAME
2450R Phenolic Annular Ring Cap Automatic Reset Thermostat
2450R/2455R Series Protected Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. Basic thermostat is protected from the environment by sealing it in a metal housing or encapsulating it in epoxy.
Reset type: Automatic Amperage capacity: 15 A resistive, 12 Vdc Housing material: Brass, aluminium, stainless steel and epoxy Operating temperature range: 15 °C to 130 °C [59 °F to 266 °F] Environmental exposure range: -40 °C to 155 °C [-40 °F to 311 °F]
SERIES NAME
2450R Fully Sealed Thermostat
SERIES NAME
2450R Protected Thermostat 2455R Protected Thermostat
30
www.honeywell.com/sensing
Page 5
Bimetal Thermostats - Sensing and Control - Honeywell Automation and Control Solutions
Temperature Sensors
Thermal Cutoffs
Thermistors & Probes
Thermostats
>Redi-Temp
Subminiature 3600 Series
>Redi-Temp Series 3100
SPST Hermetic Series
>Redi-Temp 3455 RC 15
AMP High Temp. Series
>Bimetal Precision &
Commercial Thermostats
Products & Applications Thermal Products Glossary Contact Us Request Free Literature
Bimetal Thermostats
The Honeywell bimetal thermostat product line consists of Single-Pole, Single-Throw (SPST) hermetic and non-hermetic thermostats, including low-silhouette, logic level, auto reset, manual reset, one-shot, and subminiature thermostats and thermal switches. These products are also defined by their ability to reliably maintain
precision temperature tolerances or high amperage electrical loads. They provide temperature control and overtemperature protection for the appliance, office automation, industrial, commercial aircraft and medical equipment industries.
Bimetal thermostats are snap-action devices designed to operate in extreme conditions, such as exposure to hazardous substances, dust particles and liquid immersion. Contacts are thermally and electrically isolated. Dust-proof performance is achieved by using a ceramic or phenolic base protected by a metal enclosure. A variety of custom configurations are available which provide environmental protection.
Select a product from one of the following bimetal categories:
Precision Thermostats Commercial Thermostats
Precision Thermostats
Hermetic Thermostats
Series Features Applications
3100
Tight temperature tolerances and differentials available 6 A 120 Vac rating
Environmental exposure -62 ° C to 288 °C [-80 °F to 550 °F]
Industrial glue guns Blood analyzers Battery pack heater
3106
Gold alloy cross-point contacts for use in logic level circuits Tight temperature tolerances and differentials available
Solid state control backup
3150
Low profile 7,7 mm [0.305 in] maximum design height 6 A 120Vac rating
Tight temperature tolerances and differentials available
Commercial aircraft avionics Power supplies
Copy machine overheat protection
3156
Gold alloy cross-point contacts for use in logic level circuits Low profile 7,7 mm [0.305 in] maximum design height UL recognized and CSA certified Tight temperature tolerances and differentials available
Dry circuit applications where space is limited
Custom Packaged Thermostats
Series Features Applications
Search the Sensing and Control Interactive Catalog.
Search for product and support information.
Advanced Search
All Sensing & Control
http://content.honeywell.com/sensing/prodinfo/thermostats/bimetalthermostat.asp (2 of 4)17/11/2005 09:56:24
Page 6
Bimetal Thermostats - Sensing and Control - Honeywell Automation and Control Solutions
3000 Customized probe length
Custom probe materials Many termination/connector
options
Heater control Aircraft bleed air Duct
sensing Liquid bath control
Hydraulic oil temperature control
Non-Hermetic Thermostats
Series Features Applications
3001, 3004
Low profile and lightweight (Model 3001) European approved (3004 only) Tight temperature tolerances and differentials available
Computers Office equipment Blood analyzers
High Amperage Thermostats 15 A
Series Features Applications
3450, 3455R, 3455RBV
Electrical rating to 15 A 120 Vac resistive UL recognized, CSA certified and European approved Single-pole, single-throw
Environmental exposure for the 3450 & 3455R -18 °C to 177 °C [0 °F to 350 °F] Environmental exposure for the 3455RBV -18 °C to 121 ° C [0 °F to 250 °F]
Power supplies Communications
equipment Medical equipment
Computers (where high amperage loads are present)
3450RC, 3455RC
High temperature environmental exposure -18 ° C to 288 °C [0 °F to 550 °F] Electrical rating to 15 A 120 Vac resistive UL recognized, CSA certified and European approved Single-pole, single-throw
Communications equipment Computers (where high amperage loads are present) Medical equipment
Appliances
Manual Reset Thermostats
Series Features Applications
3455RM, 3450CM
Manually resettable operation (reset button) Electrical rating to 15 A 120 Vac resistive UL recognized and CSA certified Environmental exposure 10 ° C to 177 °C [50 °F to 350 F]
Where automatic reset is not preferred
Commercial Thermostats
Phenolic Thermostats
Series Features Applications
2450R, 2450HR, 2455R
15 A, 120 Vac; 10 A, 240 Vac UL recognized, CSA certified
and European approved Contacts are available for mV and mA applications Environmental exposure 0 °C to 177 °C [32 °F to 350 °F]
Copy machines Medical equipment Power supplies
http://content.honeywell.com/sensing/prodinfo/thermostats/bimetalthermostat.asp (3 of 4)17/11/2005 09:56:24
Page 7
Bimetal Thermostats - Sensing and Control - Honeywell Automation and Control Solutions
Ceramic Thermostats
Series Features Applications
2450RC, 2450RCH, 2455RC
15 A 120 Vac; 10 A 240 Vac UL recognized, CSA certified
and European approved Contacts are available for mV and mA applications Environmental Exposure 0 °C to 177 °C [32 °F to 350 °F]
Office automation products Table-top applications
Industrial equipment Appliances
Manual Reset Thermostats
Series Features Applications
2455RM, 2450CM
15 A, 120 Vac; 10 A, 240 Vac UL recognized, CSA certified
and European approved Environmental Exposure for 2455RM -18 °C to 121 °C [0 ° F to 250 °F] Environmental exposure for 3450CM 10 °C to 260 °C [50 ° F to 500 °F]
Office automation products Medical equipment
Overmolded Automatic Reset Thermostats
Series Features Applications
2455RBV
15 A ,120 Vac; 8.3 A, 240 Vac UL recognized, CSA certified
and European approved Environmental exposure -18 ° C to 121 °C [0 °F to 250 °F]
Industrial equipment
Heat Detection Thermostats
Series Features Applications
2450A, 2455RA
UL recognized Environmental exposure 0 °C
to 150 °C [32 °F to 302 °F]
Heat detection
One-shot Thermostats
Series Features Applications
2450R, 2455R, 2450RC, 2455RC
15 A, 120 Vac; 10 A, 240 Vac UL recognized, CSA certified
and European approved Environmental exposure for 2450R & 2455R 0 °C to 177 ° C [32 °F to 350 °F] Environmental exposure for 2450RC & 2455RC 0 °C to 288 °C [32 °F to 550 °F]
Automation equipment Tabletop appliances
http://content.honeywell.com/sensing/prodinfo/thermostats/bimetalthermostat.asp (4 of 4)17/11/2005 09:56:24
Page 8
‘Permanent Stock’ of Thermostats Type 2455R
Functions: Open on Rising Temperature, and
Close on Rising Temperature
Standard Mounting Bracket: B 203 S
Terminals: horizontal T 146
Operating Temperatures in 10° C Steps.
Up to 15A and up to 250V AC
Silver contact system
Part Number Function
Open Close °C +/-K °C +/-K 2455R- 100-84 30 3 15 4 2455R- 100-72 40 3 25 6 2455R- 100-73 50 3 35 6 2455R- 100-85 60 3 45 6 2455R- 100-74 70 3 55 6 2455R- 100-75 80 3 65 6 2455R- 100-76 90 3 75 6 2455R- 100-77 100 4 80 7 2455R- 100-86 110 4 90 7 2455R- 100-98 120 4 98 6 2455R- 100-88 130 4 110 8 2455R- 100-89 140 4 115 8 2455RC- 9100-373 150 7 120 8 Close Open °C +/-K °C +/-K 2455R- 100-78 50 3 35 6 2455R- 100-79 60 3 45 6 2455R- 100-92 80 3 65 6 2455R- 100-93 90 3 75 6 2455R- 100-94 100 4 80 7 2455R- 100-95 120 4 100 7 2455R- 100-96 140 4 115 8
Loading...