Datasheet 13 Specification

Page 1
Chemical System: Zinc Air (Zn/O2)
Tab Color: Orange
Designation: IEC-PR48
Nominal Voltage: 1.4 Volts
Typical Capacity: 280 mAh (to 0.9 volts)
Typical Weight: 0.8 grams
Typical Volume: 0.3 cubic centimeters
Load Cutoff
0.9V
(ohms) (hours)
1,000 215
1,500 322
This datasheet contains typical information specific to
batteries manufactured at the time of its publication.
Contents herein do not constitute a warranty.
©Energizer Holdings, Inc. - All Rights Reserved
16 Hours/Day
1.3
Important Notice
16 Hours/Day
0.87
at 1.3V
(milliamperes)
Simulated Application Test
Schedule:
Typical Drains:
Impedance vs. Frequency
Typical Discharge Characteristics
Typical Performance at 21°C & 50% RH
Impedance vs. Depth of Discharge
Energizer AC13 - Mercury Free
Industry Standard Dimensions
Impedance
(top view)
(bottom view)
Specifications
(mm)
PRODUCT DATASHEET
0.8
0.9
1.0
1.1
1.2
1.3
1.4
0 60 120 180 240 300 360
Operating Voltage
Service, Hours
Schedule: 16 hours/day
Typical Drain @ 1.3V:
1.3 & 0.87 milliamperes
Load: 1K & 1.5K ohms
1K 1.5K
0
4
8
12
16
20
0.1 1 10 100 1000 10000 100000
Impedance (ohms)
Frequency (Hz)
00% DoD
25% DoD
50% DoD
80% DoD
0
5
10
15
20
25
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Impedance (ohms)
Depth of Discharge
40 Hz
1K Hz
The total opposition that a battery offers to the flow of
alternating current. Impedance is a combination of resistance and reactance.
The typical impedance of these cells on open circuit and during useful discharge varies from 5-20 ohms. This applies over a frequency range of 40-5,000 hertz at the current drains shown below.
+ 44 (0) 208 920 2306 www.energizer-eu.com
European Region
3.00
Minimum
1.35R
Typical
7.90
7.55
0.38
Minimum
5.00
5.40
Form No. EBC - 8836EU Page 1 of 1