Datasheet 021121007 Specification

Page 1
Low voltage - Energy and cabling
H03VV-F
Structure and electrical, physical, mechanical requirements:
Low Voltage Directive: 2014/35/UE RoHS Directive:
reaction to fire
CPR COMPLIANT
REGULATION 305/2011/EU
Standard: EN 50575:2014+A1:2016 Class: E Classification: EN 13501-6 Flame propagation: EN 60332-1-2 Notified Body: 2479 - L.S. FIRE TESTING INSTITUTE
EN 50525-2-11 (IEC 60227-5)
ca
2017
H05VV-F
Structure and electrical, physical, mechanical requirements:
Low Voltage Directive: 2014/35/UE RoHS Directive:
reaction to fire
CPR COMPLIANT
REGULATION 305/2011/EU
Standard: EN 50575:2014+A1:2016 Class: E Classification: EN 13501-6 Flame propagation: EN 60332-1-2 Notified Body: 0051 - IMQ
EN 50525-2-11 (IEC 60227-5)
ca
2017
www.latrivenetacavi.com
review n° 006 date 12/06/19
Page 2
Description
•
Conductor: class 5, flexible, plain copper wire
•
Insulation: PVC, TI2 quality
•
Sheath: PVC, TM2 quality
•
Colour: black, white, grey
Functional characteristics
•
Rated voltage H03VV-F: Uo/U 300/300 V H05VV-F: Uo/U 300/500 V
•
Max. operating temperature: 60°C
•
Min. operating temperature: -10°C (without mechanical shocks)
•
Max. short circuit temperature: 150°C
H03VV-F / Installation conditions
•
Minimum installation temperature: 5°C
•
Recommended minimum bending radius: 6 times the cable diameter
•
Recommended maximum tensile stress: 15 N/mm² of the cross-section of the copper
Use and installation method
Reference Guide EN 50565 H03VV-F: For mobile use. Use in domestic premises and offices, for light duty applications and appliances (ex. music centers, table and standard lamps, office machines). H05VV-F: For mobile use. Use in domestic premises and offices, for ordinary duty applications and household appliances, including in damp premises (ex. vacuum cleaners, washing machines, spin dryers and refrigerators). Use outdoor for temporary periods of short duration.
If both the cables are used inside equipment or the like were no contact with skin can be guaranteed the cables are suitable for maximum conductor operating temperature of 70°C.
Reference Construction Products Regulation 305/2011 EU and Standard EN 50575: The cables are suitable for the supply of electricity in buildings and other civil engineering works.
H05VV-F / Installation conditions
•
Minimum installation temperatures: 5°C
•
Recommended minimum bending radius: 6 times the cable diameter for mobile use, 4 times the cable diameter for static use
•
Recommended maximum tensile stress: 15 N/mm² of the cross-section of the copper for mobile use, 50 N/mm² for static use
Colours of the cores
TWO-CORE THREE-CORE FOUR-CORE FIVE-CORE
or
or
or
Marking
[company] IEMMEQU ◄HAR► H03VV-F [form.] [company] IEMMEQU ◄HAR► H05VV-F [form.]
review n° 006 date 12/06/19
Page 3
H03VV-F
Formation
n° x mm
N.B. The values of current rating indicated apply in most cases
2
2 x 0,5 0,9 0,5 0,6 5,9 39,0 32 3
2 x 0,75 1,1 0,5 0,6 6,3 26,0 40 6
3G0,5 0,9 0,5 0,6 6,3 39,0 38 3
3G0,75 1,1 0,5 0,6 6,7 26,0 49 6
4G0,5 0,9 0,5 0,6 6,9 39,0 47 3
4G0,75 1,1 0,5 0,6 7,3 26,0 59 6
Approx.
conductor
Ø
mm mm mm mm /km kg/km A
Average insulation thickness
Average
sheath
thickness
Max.
external
Ø
Max.
electrical
resistance
at 20°C
Approx.
cable
weight
H05VV-F
Max.
electrical
resistance
at 20°C
Approx.
cable
weight
Formation
n° x mm
2
Approx.
conductor
Ø
mm mm mm mm /km kg/km A
Average insulation thickness
Average
sheath
thickness
Max.
external
Ø
Current rating
in air
at 30°C
Current rating
in air
at 30°C
2 x 0,75 1,1 0,6 0,8 7,2 26,0 51 6
2 x 1 1,3 0,6 0,8 7,5 19,5 58 10
2 x 1,5 1,5 0,7 0,8 8,6 13,3 79 16
2 x 2,5 2,0 0,8 1,0 10,6 7,98 120 20
2 x 4 2,5 0,8 1,1 12,1 4,95 170 25
3G0,75 1,1 0,6 0,8 7,6 26,0 60 6
3G1 1,3 0,6 0,8 8,0 19,5 70 10
3G1,5 1,5 0,7 0,9 9,4 13,3 100 16
3G2,5 2,0 0,8 1,1 11,4 7,98 160 20
3G4 2,5 0,8 1,2 13,1 4,95 212 25
4G0,75 1,1 0,6 0,8 8,3 26,0 73 6
4G1 1,3 0,6 0,9 9,0 19,5 89 10
4G1,5 1,5 0,7 1,0 10,5 13,3 125 16
4G2,5 2,0 0,8 1,1 12,5 7,98 190 20
4G4 2,5 0,8 1,2 14,3 4,95 260 25
5G0,75 1,1 0,6 0,9 9,3 26,0 90 6
5G1 1,3 0,6 0,9 9,8 19,5 110 10
5G1,5 1,5 0,7 1,1 11,6 13,3 150 16
5G2,5 2,0 0,8 1,2 13,9 7,98 230 20
5G4 2,5 0,8 1,4 16,1 4,95 335 25
N.B. The values of current rating indicated apply in most cases
review n° 006 date 12/06/19