DATASENSOR S50-Mx Instruction Manual

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: info@ctiautomation.net
S50-Mx SERIES
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (S50-Mx…A00/B01/C01/C10/C21/E01/F01/T01)
The yellow LED ON indicates that the N.O. (normally open) output status is closed.
STABILITY LED (S50-Mx…B01/C01/C21/E01/F01)
The green LED ON indicates that the received signal has a reserve greater than 30% compared to the output switching value.
POWER ON LED (S50-Mx…G00)
The green LED indicates that the sensor is operating.
TRIMMER (S50-Mx…B01/C01/C21/E01/F01/T01)
The trimmer can be used to adjust sensitivity; the operating distance increases turning the trimmer clockwise.
WARNING: The trimmer rotation is limited to 270° by a mechanical stop. Do not apply excessive torque when adjusting (max 40 Nmm).
INSTALLATION
The sensor can be fixed by means of the M18x1 threaded body through a 18 mm hole, using the two CH.24 nuts enclosed (22 Nm maximum tightening torque). Wide range of accessories available: various orientable fixing brackets ease the sensor positioning (please refer to the accessories listed in the general catalogue). The operating distance is measured from the front surface of the sensor lens. C/D models: To improve the detection, the object has to be moved closer or further away from the front surface of the sensor lens.
In case of lateral translation, the object must move as indicated in the figure.
CONNECTIONS
The connections are compliant to the EN 60947-5-2 standard.
BROWN
WHITE
BLACK
BLUE
M12 CONNECTOR
1
10 … 30 Vdc
+
2
N.C. OUTPUT
4
N.O. OUTPUT
3
0 V
2
3
BROWN
WHITE
BLACK
BLUE
1
4
S50-Mx…G00
1
10 … 30 Vdc
+
2
TEST +
4
TEST -
3
0 V
DIMENSIONS
without trimmer
57 38
14.572.5
10
STABILITY LED
24
RADIAL VERSION
12
14
14.5 10
M18x1
=
M12
6.2 =
L
44
X
61
24
14.5
TRIMMER
LED STABILITY
LED DI USCITA
CABLE VERSION
AXIAL VERSION
4
4
X
2.5
=
M18x1
49
L
TRIMMER
OUTPUT LED
14.5
STABILITY LED
FIBRE OPTIC VERSION
12
Ø22
Ø2.2
10
=
M12
4
50
54.5
M O D E L S
with trimmer
L
67
X
43
M18x1
TRIMMER
OUTPUT LED
TECHNICAL DATA
Power supply: 10 … 30 Vdc (limit values) Ripple: 2 Vpp max. Current consumption (output current excluded): Outputs: N.O. and N.C.; PNP or NPN (short-circuit protection) Output current: 100 mA max. Output saturation voltage: 2 V max. Response time: 0.5 ms (2 ms mod.F01/G00) Switching frequency: 1 kHz (250 Hz mod.F01/G00) Indicators: OUTPUT LED (YELLOW) excluding mod.G00
Setting: sensitivity trimmer (mod.B01/C01/C21/E01/F01/T01) Operating temperature: -25 … 55 °C Storage temperature: -25 … 70 °C Electrical shock protection: Class 2 Operating distance (typical values): A00: 0.1…4 m on R2
Emission type: red (660 nm) (mod.B01/D00/E01/T01) / infrared (880 nm) (mod.A00/C01/C10/C21/G00) Ambient light rejection: according to EN 60947-5-2 Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27) Housing material: Nickel-plated brass Lens material: PMMA Mechanical protection: IP67 Connections: Weight: 110 g. max. cable vers. / 60 g. max. connector vers.
S50-MA AXIAL VERSION S50-MR RADIAL VERSION
35 mA max.
STABILITY LED (GREEN) (mod.B01/C01/C21/E01/F01)
POWER ON LED (GREEN) (mod.G00)
B01: 0.1…3.5 m on R2
C01: 0…60 cm C10: 0…10 cm C21: 0…35 cm
D00: 0.5…10 cm
E01: 30 mm with OF-42 / 100 mm with OF-43
F01/G00: 0…15 m
T01: 0.1…1 m on R2
B01: 0.1…2 m on R2
C01: 0…35 cm
C10: 0…8 cm D00: 0…8 cm
F01/G00: 0…10 m
T01: 0.1…1 m on R2
2 m cable 4 mm / M12 - 4 pole connector
M12
OUTPUT LED
with trimmer
L X
10
STABILITY LED
M O D E L S
79 43
Ø4
without trimmer
69 38
mm
SETTING
Setting of S50-Mx…A00
Position the sensor and reflector on opposite sides. Find the points where the yellow LED (OUT) is switched ON and OFF in both vertical and horizontal positions, and fix the sensor in the centre between these points.
24
Setting of S50-Mx…B01/T01
Position the sensor and reflector on opposite sides. Turn the sensitivity trimmer to the maximum position. Moving the sensor both vertically and horizontally, determine the power on and off points of the yellow LED (OUT) and then mount the sensor in the middle of the points defined. Optimum operation is obtained when the green LED (mod.B01) is ON and the yellow LED is OFF. B01 models: If necessary reduce sensitivity in order to detect very small targets. In order to improve alignment, repeat the procedure detailed above whilst progressively reducing the sensitivity. T01 model: Turn the sensitivity trimmer counterclockwise until the yellow LED turns ON (pos.A). Turn slowly the trimmer again clockwise until the yellow LED turns OFF (Operating condition, pos.B).
Setting of S50-Mx…F01/G00/E01 with OF-43 (P/R fibre-optics)
Position the sensors (fibre terminals) on opposite sides. Turn the sensitivity trimmer to maximum: moving the sensor both vertically and horizontally, determine the power on and off points of the yellow LED (OUT) and then mount the sensor in the middle of the points defined. Optimum operation is obtained when the green LED is ON and the yellow LED is OFF (the output function and the relative LEDs are inverted in the E01 model with the OF-43 fibre). If necessary, reduce sensitivity using the trimmer, in order to detect very small targets. In order to improve alignment, repeat the procedure detailed above whilst progressively reducing the sensitivity.
Setting of S50-Mx…C01/C21/E01 with OF-42 (proximity fibre)
Turn the sensitivity trimmer to minimum: the green LED is ON, the yellow LED is OFF. Position the target to detect in front of the sensor or of the fibre terminals. Turn the sensitivity trimmer clockwise until the yellow LED turns ON (Target detected state, pos.A). Remove the target, the yellow LED turns OFF. Turn the sensitivity trimmer clockwise until the yellow LED turns ON (Background detected state, pos.B). The trimmer reaches maximum if the background is not detected. Turn the trimmer to the intermediate position C, between the two positions A and B. The green LED must be ON.
Setting of S50-Mx…C10/D00
The operating distance range of these sensors is factory preset: please consider this feature when positioning.
TEST FUNCTION (S50-Mx…G00)
The TEST+ and TEST- inputs can be used to inhibit the emitter and verify that the system is correctly operating. The receiver output should switch when the test is activated while the beam is uninterrupted. The inputs activating voltage range is 10 … 30 Vdc.
DECLARATION OF CONFORMITY
We DATASENSOR S.p.A. declare under our sole responsibility that these products are conform to the 2004/108 CEE, 73/23 CEE Directives and successive amendments.
WARRANTY DATASENSOR S.p.A. warrants its products to be free from defects. DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during the warranty period of 36 months from the manufacturing date. This warranty does not cover damage or liability deriving from the improper application of DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265 40050 Monte S. Pietro - Bologna - Italy Tel: +39 051 6765611 Fax: +39 051 6759324 http://www.datasensor.com e-mail: info@datase nsor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled paper. DATASENSOR S.p.A. reserves the right to make modifications and improvements without prior notification.
826001323 Rev.C
A
C
B
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: info@ctiautomation.net
S50-Px SERIES
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (S50-Px…A00/B01/C01/C10/C21/E01/F01/T01)
The yellow LED ON indicates that the NO output status is closed.
STABILITY LED (S50-Px…B01/C01/C21/E01/F01)
The green LED ON indicates that the received signal has a reserve greater than 30% compared to the output switching value.
POWER ON LED (S50-Px…G00)
The green LED indicates that the sensor is operating.
TRIMMER (S50-Px…B01/C01/C21/E01/F01/T01)
The trimmer can be used to adjust sensitivity; the operating distance increases turning the trimmer clockwise.
WARNING: The trimmer rotation is limited to 270° by a mechanical stop. Do not apply excessive torque when adjusting (max 40 Nmm).
INSTALLATION
The sensor can be fixed by means of the M18x1 threaded body through a 18mm hole, using the specific washer and the two CH.24 nuts enclosed (1.5Nm maximum tightening torque). Alternatively, the sensor can be mounted through the two housing’s holes using two screws (M3x22 or longer) and washer. Amongst the various possible solutions, we suggest to choose the combination that offers the best visibility of the signalling LEDs and the easiest access to the trimmer. Wide range of accessories available: 22mm nuts, h=8mm, (2Nm maximum tightening torque) guarantee an improved torque and various orientable fixing brackets ease the sensor positioning (please refer to the accessories listed in the general catalogue). The operating distance is measured from the front surface of the sensor lens. C/D models: To improve the detection, the object has to be moved closer or further away from the front surface of the sensor lens. In case of lateral translation, the object must move as indicated in the figure.
CONNECTIONS
The connections are compliant to the EN 60947-5-2 standard.
BROWN
WHITE
BLACK
BLUE
M12 CONNECTOR
1
10 … 30 Vdc
+
2
NC OUTPUT
4
NO OUTPUT
3
0 V
2
3
BROWN
WHITE
BLACK
BLUE
1
4
S50-Px…G00
1
10 … 30 Vdc
+
2
TEST +
4
TEST -
3
0 V
DIMENSIONS
without trimmer
57 42 24
10
STABILITY LED
24
RADIAL VERSION
12
2
=
14
3.8
3.5
14.5
X1
6.2 =
=
M12
L
1.5
44
25
X
M18x1
N°.2 Ø3.8
15
24
TRIMMER
OUTPUT LED
14.5
=
14
10
=
M12
L
STABILITY LED
X
X1
CABLE VERSION
10
STABILITY LED
OUTPUT LED
AXIAL VERSION
2
1.5
=4=
14
3.8
3.5
2.5
=
M18x1
X1
L
4
25
X
TRIMMER
N°.2 Ø3.8
OUTPUT LED
15
FIBRE OPTIC VERSION
Ø22
Ø2.2
14.5
10
=
M12
STABILITY LED
72.5 14.5
1.512
4
4
39.5 15
N°.2 Ø3.8
M O D E L S
with trimmer
L
67
X
43
X1
34
14
25
TRIMMER
M18x1
OUTPUT LED
TECHNICAL DATA
Power supply: 10 … 30 Vdc (limit values) Ripple: 2 Vpp max. Current consumption (output current excluded): Outputs: NO and NC; PNP or NPN (short-circuit protection) Output current: 100 mA max. Output saturation voltage: 2 V max. Response time: 0.5 ms (2 ms mod.F01/G00) Switching frequency: 1KHz (250 Hz mod.F01/G00) Indicators: OUTPUT LED (YELLOW) excluding mod.G00
Setting: sensitivity trimmer (mod.B01/C01/C21/E01/F01/T01) Operating temperature: -25 … 55 °C Storage temperature: -25 … 70 °C Electrical shock protection: Class 2 Operating distance (typical values): A00: 0.1…4m on R2
Emission type: red (660 nm) (mod.B01/D00/E01/T01) / infrared (880nm) (mod.A00/C01/C10/C21/G00) Ambient light rejection: according to EN 60947-5-2 Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27) Housing material: PBT Lens material: PMMA Mechanical protection: IP67 Connections: Weight: 75 g. max. cable vers. / 25 g. max. connector vers.
S50-PA AXIAL VERSION S50-PR RADIAL VERSION
35 mA max.
STABILITY LED (GREEN) (mod.B01/C01/C21/E01/F01)
POWER ON LED (GREEN) (mod.G00)
B01: 0.1…3.5m on R2
C01: 0…60cm C10: 0…10cm C21: 0…35cm
D00: 0.5…10cm
E01: 30mm with OF-42 / 100mm with OF-43
F01/G00: 0…15m
T01: 0.1…1m on R2
B01: 0.1…2m on R2
C01: 0…35cm
C10: 0…8cm D00: 0…8cm
F01/G00: 0…10m
T01: 0.1…1m on R2
2 m cable 4 mm / M12 - 4 pole connector
M O D E L S
with trimmer
79 43 46
SETTING
Setting of S50-Px…A00
Position the sensor and reflector on opposite sides. Find the points where the yellow LED (OUT) is switched ON and OFF in both vertical and horizontal positions, and fix the sensor in the centre between these points.
24
Setting of S50-Px…B01/T01
Position the sensor and reflector on opposite sides. Turn the sensitivity trimmer to the maximum position. Moving the sensor both vertically and horizontally, determine the power on and off points of the yellow LED (OUT) and then mount the sensor in the middle of the points defined. Optimum operation is obtained when the green LED (mod.B01) is ON and the yellow LED is OFF. B01 models: If necessary reduce sensitivity in order to
without trimmer
mm
Ø4
detect very small targets. In order to improve alignment, repeat the procedure detailed above whilst progressively
69
reducing the sensitivity.
42 36
T01 model: Turn the sensitivity trimmer counterclockwise until the yellow LED turns ON (pos.A). Turn slowly the trimmer again clockwise until the yellow LED turns OFF (Operating condition, pos.B).
Setting of S50-Px…F01/G00/E01 with OF-43 (P/R fibre-optics)
Position the sensors (fibre terminals) on opposite sides. Turn the sensitivity trimmer to maximum: moving the sensor both vertically and horizontally, determine the power on and off points of the yellow LED (OUT) and then mount the sensor in the middle of the points defined. Optimum operation is obtained when the green LED is ON and the yellow LED is OFF (the output function and the relative LEDs are inverted in the E01 model with the OF-43 fibre). If necessary, reduce sensitivity using the trimmer, in order to detect very small targets. In order to improve alignment, repeat the procedure detailed above whilst progressively reducing the sensitivity.
Setting of S50-Px…C01/C21/E01 with OF-42 (proximity fibre)
Turn the sensitivity trimmer to minimum: the green LED is ON, the yellow LED is OFF. Position the target to detect in front of the sensor or of the fibre terminals. Turn the sensitivity trimmer clockwise until the yellow LED turns ON (Target detected state, pos.A). Remove the target, the yellow LED turns OFF. Turn the sensitivity trimmer clockwise until the yellow LED turns ON
(Background detected state, pos.B).
The trimmer reaches maximum if the background is not detected. Turn the trimmer to the intermediate position C, between the two positions A and B. The green LED must be ON.
Setting of S50-Px…C10/D00
The operating distance range of these sensors is factory preset: please consider this feature when positioning.
A
C
B
TEST FUNCTION (S50-Px…G00)
The TEST+ and TEST- inputs can be used to inhibit the emitter and verify that the system is correctly operating. The receiver output should switch when the test is activated while the beam is uninterrupted. The inputs activating voltage range is 10 … 30 Vdc.
DECLARATION OF CONFORMITY
We DATASENSOR S.p.A. declare under our sole responsibility that these products are conform to the 2004/108 CEE, 73/23 CEE Directives and successive amendments.
WARRANTY DATASENSOR S.p.A. warrants its products to be free from defects. DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during the warranty period of 36 months from the manufacturing date. This warranty does not cover damage or liability deriving from the improper application of DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265 40050 Monte S. Pietro - Bologna - Italy Tel: +39 051 6765611 Fax: +39 051 6759324 http://www.datasensor.com e-mail: info@datase nsor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled paper. DATASENSOR S.p.A. reserves the right to make modifications and improvements without prior notification.
826001243 Rev.D
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: info@ctiautomation.net
S50-PL/ML SERIES
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (S50-PL/ML…B01/C01/F01/)
The yellow LED ON indicates that the N.O. (normally open) output status is closed.
POWER ON LED
The green LED indicates that the sensor is operating.
TRIMMER (S50-PL/ML…B01/C01/F01)
The trimmer can be used to adjust sensitivity; the operating distance increases turning the trimmer clockwise.
WARNING
mechanical stop. Do not apply excessive torque when adjusting (max 40 Nmm).
S50-PL: The sensor can be fixed by means of the M18x1 threaded body through a 18 mm hole, using the specific washer and the two CH.24 nuts enclosed (1.5 Nm maximum tightening torque). Alternatively, the sensor can be mounted through the two housing’s holes using two screws (M3x22 or longer) and washer. Amongst the various possible solutions, we suggest to choose the combination that offers the best visibility of the signalling LEDs and the easiest access to the trimmer. 22 mm nuts, h=8 mm, (2 Nm maximum tightening torque) are available to guarantee an improved torque.
S50-ML: The sensor can be fixed by means of the M18x1 threaded body through a 18 mm hole, using the specific washer and the two CH.24 nuts enclosed (22 Nm maximum tightening torque).
For both plastic version and metallic version are available various orientable fixing brackets to ease the sensor positioning (please refer to the accessories listed in the general catalogue). The operating distance is measured from the front surface of the sensor lens. In case of lateral translation, the object must move as indicated in the figure.
: The trimmer rotation is limited to 270° by a
INSTALLATION
CONNECTIONS
The connections are compliant to the EN 60947-5-2 standard.
S50-PL/ML…B01/C01/F01
BROWN
WHITE
BLACK
BLUE
1
2
4
3
10 … 30 Vdc
+
N.C. OUTPUT
N.O. OUTPUT
0 V
S50-PL/ML…G00
BROWN
WHITE
BLACK
BLUE
M12 CONNECTOR
1
10 … 30 Vdc
+
2
TEST +
4
NOT USED
3
0 V
2
3
DIMENSIONS
S50-PL VERSIONS S50-ML VERSIONS
2
=4=
14
3.8
3.5
2.5
=
M18x1
L
1.5
4
25
X
N°.2 Ø3.8
X1
15
TRIMMER
OUTPUT LED
14.5
10
POWER ON LED
M O D E L S
B/C/F version
L
67
X
43
X1
34
CABLE VERSION
=
M12
OUTPUT LED
10
POWER ON LED
G version
57 42 24
24
2.5
Ø4
=
M18x1
mm
L
4
4
X
49
TRIMMER
OUTPUT LED
14.5
10
POWER ON LED
CABLE VERSION
=
M12
TECHNICAL DATA
Power supply: 10 … 30 Vdc (limit values) Ripple: 2 Vpp max. Current consumption (output current excluded): Outputs: N.O. and N.C.; PNP or NPN (short-circuit protection) Output current: 100 mA max. Output saturation voltage: 2 V max. Response time: Switching frequency: 1,5 kHz Indicators: OUTPUT LED (YELLOW) (mod.B01/C01/F01) / POWER ON LED (GREEN) Setting: sensitivity trimmer (mod.B01/C01/F01) Operating mode: LIGHT mode on N.O. output / DARK mode on N.C. output (mod.C01)
Operating temperature: -10 … 50 °C Storage temperature: -25 … 70 °C Electrical shock protection: Class 2 Operating distance (typical values):
Emission type: RED LASER: Class 1 EN 60825-1 (1994) (mod.B01/C01/G00)
Ambient light rejection: according to EN 60947-5-2 Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27) Housing material: PBT Nickel plated brass Lens material: PMMA Mechanical protection: IP67 Connections: Weight: 75 g. max. cable vers./25 g. max. connector vers. 110 g. max. cable vers./60 g. max. connector vers.
S50-PL PLASTIC VERSIONS S50-ML METALLIC VERSIONS
35 mA max. (mod.B01/C01/F01)
30 mA max (mod.G00)
333 µs
DARK mode on N.O. output / LIGHT mode on N.C. output (mod.B01/F01)
B01: 0.1…16 m on R2
C01: 0…35 cm
F01/G00: 0…60 m
Class II CDRH 21 CFR PART 1040.10 (mod.B01/C01/G00)
Max. power 1 mW; Pulse = 4.5 µS; λ = 630…680nm; Frequency =25 kHz
2 m cable 4 mm / M12 - 4 pole connector
1
4
B/C/F version
LX67
OUTPUT LED
M O D E L S
43
10
POWER ON LED
G version
SETTING
Setting of S50-PL/ML…B01
Position the sensor and reflector on opposite sides. Turn the sensitivity trimmer to the maximum position. Moving the sensor both vertically and horizontally, determine the power ON and OFF points of the OUTPUT LED and then mount the sensor in the middle of the points defined. If necessary reduce sensitivity in order to detect very small targets. In order to improve alignment, repeat the procedure detailed above whilst progressively reducing the sensitivity.
Setting of S50-PL/ML…F01/G00
Position the sensors on opposite sides. Turn the sensitivity trimmer to maximum: moving the sensor both vertically and horizontally, determine the power ON and OFF points of the OUTPUT LED and then mount the sensor in the middle of the points defined.
57
If necessary, reduce sensitivity using the trimmer, in order to
38
detect very small targets. In order to improve alignment, repeat the procedure detailed above whilst progressively reducing the sensitivity.
24
Setting of S50-PL/ML…C01
Turn the sensitivity trimmer to minimum: the OUTPUT LED is OFF. Position the target to detect in front of the sensor.
A
C
B
Turn the sensitivity trimmer clockwise until the OUTPUT LED
Ø4
turns ON (Target detected state, pos.A). Remove the target, the OUTPUT LED turns OFF. Turn the sensitivity trimmer clockwise until the OUTPUT LED turns ON (Background detected state, pos.B). The trimmer reaches maximum if the background is not detected. Turn the trimmer to the intermediate position C, between the two positions A and B.
TEST FUNCTION (S50-PL/ML…G00)
The TEST input can be used to inhibit the emitter and verify that the system is correctly operating. The receiver output should switch when the test is activated while the beam is uninterrupted. The input activating voltage range is 10…30 Vdc.
DECLARATION OF CONFORMITY
We DATASENSOR S.p.A. declare under our sole responsibility that these products are conform to the 2004/108 CEE, 73/23 CEE Directives and successive amendments.
WARRANTY DATASENSOR S.p.A. warrants its products to be free from defects. DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during the warranty period of 36 months from the manufacturing date. This warranty does not cover damage or liability deriving from the improper application of DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265 40050 Monte S. Pietro - Bologna - Italy Tel: +39 051 6765611 Fax: +39 051 6759324 http://www.datasensor.com e-mail: info@datase nsor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled paper. DATASENSOR S.p.A. reserves the right to make modifications and improvements without prior notification.
826001341 Rev.C
Loading...
+ 6 hidden pages