DATASENSOR LD46-UL Instruction Manual

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
LD46-UL
Luminescence sensor
INSTRUCTION MANUAL
OUT LED (yellow)
The yellow LED indicates the output status.
READY LED (green)
During functioning, the green LED permanently ON indicates a normal operating condition and blinking indicates an output overload condition.
DELAY LED (orange)
The orange DELAY LED ON indicates the timing function activation on the digital output.
KEYLOCK LED (orange)
The orange KEYLOCK LED ON indicates the active keyboard status.
BARGRAPH
The reading sensitivity level is signalled on the bargraph.
PUSH-BUTTON (white)
The pressing of the sensitivity and activates the digital output timing.
(red) and (green) push-buttons
The sensitivity adjustment procedure is activated by pressing the push-buttons.
See the “SETTING” paragraph for setup procedure indications.
The sensor can be positioned by means the two Ø3.5mm housing’s holes using or threaded M5 holes with 6 mm max. depth. Warning: the use of excessively long screws can damage the product.
The connector can be oriented at five different positions by rotating the block. The position chosen is guaranteed by a mechanical blocking system. The rotation can be carried-out even after sensor installation as the connector block is completely self-contained inside the housing.
Operating distance is rated starting from the lens front face.
push-button unlocks the keyboard, memorises the
and
INSTALLATION
CONNECTIONS
LD46-UL-735
(40mm LENS)
LD46-UL-755
(22mm LENS)
Ø18.8
Ø33
M20x0.75
Ø28
21.5
25.4 8.5
28
31.5
TECHNICAL DATA
Power supply: 15…30 Vdc limits value Ripple: 2 Vpp max. Consumption
(output current excluded):
Output:
50mA max @ 24Vcc
1 PNP output
1 NPN output Output current: 100 mA max. Output saturation voltage:
2 V Analogue output: 0.75 … 5.5 V max. Analogue output
impedance: Response time:
(short-circuit protection)
2.2 k
250 µs
Switching frequency: 2 kHz Delay:
0 / 20 ms selectable
(no-delay default configuration)
OUT LED (yellow) / READY LED (green)
Indicators:
DELAY LED and KEYLOCK LED (orange)
5-segment bargraph Push-buttons: +, SET, ­Operating temperature: -10 … 55 °C Storage temperature: -20 … 70 °C Electric shock protection:
double insulation
10 … 20 mm (LD46-UL-715)
Operating distance:
20 … 40 mm (LD46-UL-755)
30 … 50 mm (LD46-UL-735)
2 x 8 m m @10mm (LD46-UL-715)
Minimum spot dimension:
3x11 mm @ 24mm (LD46-UL-755)
4x15 mm @ 50mm(LD46-UL-735) Emission type: UV 375nm LEDs, Class 1 Ambiente light rejection: according to EN 60947-5-2
Vibrations:
Shock resistance:
0.5 mm amplitude, 10 … 55 Hz frequency, per each axis (EN60068-2-6)
11 ms (30 G) 6 shock per each axis
(EN60068-2-27) Housing material: Aluminium Lens material: Glass Mechanical protection: IP67 Connections: M12 5-pole connector Weight: 180 g. max.
Ø18.8
LD46-UL-715
(9mm LENS)
M20x0.75
4.8
DIMENSIONS
Ø18.8
Ø25
M20x0.75
N°2 M5 depth 6mm
3.5mm passing holes
60.7
44.7
4
31.9
2
15.8
39.1
27.5 79
28
28
62.9
24
40
M12x1
15.5
N°4 M5 depth 6mm max.
7.4
5
21
mm
SETTING
KEYLOCK function (patent-covered)
The KEYLOCK function deactivates the keyboard thus avoiding accidental changes in the sensor setting. At sensor powering the keyboard is blocked (KEYLOCK LED OFF). To
activate it, press ON. The keyboard is automatically blocked if not used for 2 minutes. Unblock the keyboard to proceed with sensor adjustment.
NORMAL FUNCTIONING
During normal functioning a LED on the bargraph visualises the sensitivity level.
SENSITIVITY ADJUSTMENT
This mode regulates the sensor reading sensitivity, i.e. the capability of detecting objects with different luminescence degrees.
The sensitivity is increased or decreased by pressing the
or push-buttons.
The adjustment speed is increased by keeping the
push-buttons pressed.
or The sensitivity level which is being set blinks on the bargraph during this
phase.
Low
Medium-Low
Medium
Medium-High High
Press
to memorise the new threshold value or wait 30sec for automatic
save.
for 5 seconds until the KEYLOCK LED (orange) turns
Sensitivity Bargraph
DELAY SETTING
The DELAY extends the minimum active output status duration to 20ms, allowing even slower interface systems to detect shorter pulses. The delay is signalled by the corresponding orange LED ON.
OUT without DELAY
OUT with DELAY
ON
OFF ON
OFF
20ms 20ms
Delay activation
- Press
for 2 sec until DELAY LED turns ON.
Delay deactivation
- Press
for 2 sec until DELAY LED turns
OFF.
OUTPUT OVERLOAD
The digital output overload is signalled by the rapid blinking of the READY LED.
ANALOGUE OUT PUT
The analogue output supplies a voltage proportional to the signal received by the sensor. The voltage supplied is 0.75 ÷ 5.5V.
DETECTION DIAGRAM
EX-II-3DG IP67 T6
Temperature class: Max. Power consumption: 1500 mW at 30 Vdc Max. Internal capacitance: 380 pF Internal inductance: negligible
DECLARATION OF CONFORMITY
We DATASENSOR S.p.A. declare under our sole responsibility that these products are conform to the 2004/108/CE, 2006/95/CE Directives and successive amendments.
WARRANTY DATASENSOR S.p.A. warrants its products to be free from defects. DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during the warranty period of 36 months from the manufacturing date. This warranty does not cover damage or liability deriving from the improper application of DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265 40050 Monte S. Pietro - Bologna - Italy Tel: +39 051 6765611 Fax: +39 051 6759324 http://www.datasensor.com e-mail: info@datasensor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled paper. DATASENSOR S.p.A. reserves the right to make modifications and improvements without prior notification.
826003232 Rev.B
T6 (<85°C)
Loading...