Dataman S6 User Manual

Dataman-S6 - User's Manual
Dataman-S6
Compact USB Programmer
User's Manual
Dataman-S6 - User's Manual
Contents
Chapter 1 Product Description
1-1 Introduction 1-2 Safety Information 1-3 Precautions 1-4 Operating System, Hardware Requirements 1-5 Accessories
Chapter 2 Product Installation
2-1 Hardware Installation 2-2 Software Installation 2-3 Driver Installation
Chapter 3 IC Insertion
3-1 General IC Insertion (DIP package) 3-2 Special IC Insertion via Adapter (Special package)
Chapter 4 Software Operation
4-1 Main Screen
4-1-1 IC Information Column 4-1-2 Message Window 4-1-3 Programming Result Statistics 4-1-4 Other Operation Buttons
4-2 Device Select/Project
4-2-1 Device Select 4-2-2 Device Type 4-2-3 Device Search 4-2-4 Device Search Operators 4-2-5 Device Search Results 4-2-6 Selected Device History
4-3 File Load
4-3-1 Load File Path 4-3-2 File Format 4-3-3 Source Select 4-3-4 Destination Select 4-3-5 “Fill Unused With” Function
4-4 Edit
4-4-1 Display Mode (8 Bits/16 Bits) 4-4-2 View/Edit Mode
4-5 Option Settings
4-5-1 General System Settings 4-5-2 Insertion Detection 4-5-3 Device ID Check
Dataman-S6 - User's Manual
4-5-4 Confirm Error List 4-5-5 Programming Area Selection 4-5-6 Message Column Settings 4-5-7 Self-Test Function 4-5-8 Device Options
4-6 Save
4-6-1 Save File Path and Name 4-6-2 Save File Format 4-6-3 Buffer Range for Saving
4-7 Device Processing Procedure
4-7-1 Read 4-7-2 Data Confirm 4-7-3 Erase 4-7-4 Blank Check 4-7-5 Program 4-7-6 Verify 4-7-7 Protect 4-7-8 RUN ALL 4-7-9 Description of Actions
Chapter 5 Basic Operation Examples
5-1 Programming an MCU from user data located on the computer and protecting the IC 5-2 Reading the internal memory of an IC and saving the data out in Binary format 5-3 Using the system's Self Test function to detect and test the programmers hardware
Chapter 6 Troubleshooting
Chapter 7 Glossary of Terms
Dataman-S6 - User's Manual
Chapter 1 Product Description
1-1 Introduction
With 30 years experience Dataman is the world’s leading provider of device programmers. We offer a comprehensive range of programming solutions suitable for every requirement from design and development to large scale production.
We are committed to providing continued development, manufacturing and support and to deliver customer specific innovative solutions.
All Dataman products come with comprehensive warranties, free lifetime support and free software updates via our website and telephone helpdesk.
1-2 Safety Information
All the operations, maintenance and repair services are required to follow the below safety information. We do not take responsibility for unexpected problems by misusing the equipment.
1. The programmer must be connected to the host computer using the supplied Y type USB cable. Check that both USB plugs are connected to the computer and confirm that the available USB power is sufficient to operate the programmer correctly. If the computer is connected through a USB Hub it will need to be a powered hub (+5V/1A or above).
2. Do not operate the product near flammable gases. High-temperatures and humidity should also be avoided.
3. Do not remove the product's case to adjust or replace any internal parts.
4. Sockets or adapters are considered consumables. The life time is determined from the frequency of use specified in the manufactures specification. If a socket is used beyond the rated number of actuations specified by the manufacturer, the socket will start to give errors caused by poor contact. This will result in an increasing number of contact errors and burn failures.
5. When using this product as mass production or production for master tape, please take the appropriate testing precautions before assembling the completed product. All the risks attributed to using the product or operating the software are undertaken by the user.
6. This manual is for reference and preservation of the consumer. Product specifications and manuals are subject to change without notice.
7. The company or trademarks mentioned in this manual are the property of their respective owners.
1-3 Precautions
1. When you work with your IC using our programmer it will access the device using a high frequency signal. To ensure proper programming and high yield rates you must observe the following:
a) During any operation with the IC (read / verify / programming / erase / blank check ...
etc) do not touch the IC or ZIF socket. When inserting an IC into the ZIF socket, please take note of basic electrostatic protection measures.
1
Dataman-S6 - User's Manual
b) If you need adapters for other kinds of IC package (for example, TSOP, PLCC, TQFP,
QFN ... etc.) we would advise that you contact Dataman. Do not use inferior quality adapters or try to create adapters yourself. The Dataman-S6 programmer communicates with the IC using a high-frequency signal. If external adapters are of poor quality we will be unable to give any guarantee on the programming results!
2. When connecting the Dataman-S6 programmer to the computer please note:
a) You must use the supplied Y-type USB cable. Check that both USB plugs are
connected to the host computer before connecting the programmer. An ordinary single USB cable is not suitable as it will not supply enough power to the unit and you may experience problems with stability during programming.
b) When the Dataman-S6 software is launched and connection to the programmer is
established the programmer will check the USB power supply, if the power supply is not sufficient a warning message will be displayed. If you are using an external USB hub its supply may be limited. In which case you would need to use a power adapter capable of (5V, 1A or greater) to improve it.
On the warning message window you can press the "Retry" button to re-test the supply once you have made a change. You can also press the "Cancel" button to skip the power detection. However by doing so the system can not guarantee 100% correct operation.
1-4 Operating System, Hardware Requirements
Operating System: Windows XP / Windows Vista / Windows 7
CPU: PC / Pentium IV or above
Memory: 512 MB RAM or above
Hard disk space: 500 MB or more (main program)
1 GB or more (program buffer (depending on selected device capacity))
Monitor Resolution: 800 x 600 pixels or above
Interface: USB 2.0 High Speed
2
Dataman-S6 - User's Manual
Power Requirements: 2 x USB Ports providing +5 V power supply
Dimensions: 130 (L) x 90 (depth) x 20 (high) mm
Note: Height does not include ZIF Socket
Weight: 290g
Operating temperature: +5 to +45
1-5 Accessories
Programmer: 1
Special Y-USB cable: 1
CD-ROM (software and manual): 1
3
Dataman-S6 - User's Manual
Chapter 2 Product Installation
2-1 Hardware Installation
1. Use the supplied Y-type USB cable connected two USB ports on the host computer. If you use an external USB Hub, please connect it to a power adapter rated at (5V,> 1A or above), and remove any other USB powered devices such as external hard drives...and so on.
2. The blue LED on the Dataman-S6 will not illuminate until the software driver has been installed. After installing the driver the programmers' LED will flash twice then turn off. When in operation the LED will be illuminated, when the software is closed down the LED will turn off.
2-2 Software Installation
1. Please note that when installing the software on your computer, the operating system will require "administrator" permissions. If you do not have administrator permissions it may result in an unsuccessful installation.
2. Insert the CD, the installation screen should automatically appear. If there's no installation screen please install through "My Computer" > CD-ROM drive > and execute the AUTORUN.EXE
3. Press the "Install" button to start the installation, modify the installation path and name of the start menu link if required. Finally press the "Finish" button to complete the software installation.
4. Next, click on the database installation files on the CD (or download from www.dataman.com). This will update the IC database.
2-3 Driver Installation
1. Please install the main software on your computer first and then connect the programmer to computer using the supplied Y-type USB cable. The driver installation will automatically start.
2. The first time the programmer is connected to the host PC it will display a message about finding new hardware, and will then ask if you want to go ahead and install the driver. Please follow these steps to complete the installation.
4
Dataman-S6 - User's Manual
5
Check this item
Dataman-S6 - User's Manual
3. The path is set to "C:\Dataman Programmers\USBDrv" (Check the item “Include this location in the search”.)
4. After installation, you will see the the "Dataman-S6” device listed under “Device manager”­Control Panel \ System \ Hardware \ Device Manager. This shows that the installation was successful.
6
check this item
Set the driver path
check this item
Choose to continue the installation
Dataman-S6 - User's Manual
7
This icon represents successful driver
installation
Press [Finish] To Complete
the installation
Dataman-S6 - User's Manual
Chapter 3 IC Insertion
3-1 General IC Insertion (DIP package)
If the IC is in a DIP package it must be inserted into the programmers ZIF socket towards the bottom, with the index mark towards the top. Pin 1 of the IC should be at the upper left position as shown here.
3-2 Special IC Insertion via Adapter Socket (Special package)
When the IC is not in a DIP package you must use a suitable package adapter. If the number of pins on the DIL header underneath the adapter is less than 48 then the adapter should be placed into the ZIF socket towards the bottom as with standard DIP devices above. The adapters are usually marked with a "1" to indicate the position of pin 1 on the device. Place the IC into the adapter socket matching the position of pin 1.
8
Loading...
+ 24 hidden pages