XRF410N™ INSTALLATION
2
INTRODUCTION
XRF410N (named for its eXtended Reading Field), is a product developed mainly for T&L applications with the goal of guaranteeing an extended horizontal field of view in order to fully cover the entire width of a conveyor.
It is made up of two Matrix 410N™ model readers (optically pre-configured and not modifiable). The readers are mounted onto a metal plate at a pre-defined distance from each other (pitch), which depends on the optical model. They are also connected together electrically by the ID-NET™ network.
The system therefore is pre-assembled and pre-configured to provide simpler installation.
Each M410N-XRF reader (including spare part readers) can only be used within an ID-NET network in which at least one other reader is present. They cannot be used as Stand Alone devices.
The various XRF410N models do not include CBX connection boxes or CBX connecting cables so it is necessary to refer to the accessories list tables for the required material.
In terms of product performance there are two models:
- BP (Base Performance) for low cost applications and medium line speed. These models have High Power Super Narrow Angle illuminators and use Image Cropping (to avoid the presence of multiple packs inside the acquired image simultaneously).
- HP (High Performance) for high line speed applications. These models have Ultra High Power illuminators and use full-frame images in PackTrack™ mode.
In addition, each of these is further divided into different optical models which are optimized for different code resolutions, reading distances and field of view.
XRF410N™ INSTALLATION
3
The following table summarizes the main characteristics of the various models:
Model
XRF410N
1D Code
Resolution
Pitch [mm]
Lighting
System
Reading
Distance
[mm]
DOF
[mm]
Focus
Dist.
[mm]
PPI
FOV min.
[mm]
Overlap
min
between
readers
[mm]
Others
BP- B0x
Medium Res
0.38mm (15mils)
235
LT-10
1270-
1670
400
1570
91
590
120
Cropped
Image:
1600x780
BP- B1x
High Res
0.33mm (13mils)
175
LT-10
1050-
1450
400
1300
111
470
120
Cropped
Image
1600x780
HP- H0x
Medium Res
0.38mm (15mils)
235
LT-20
1270-
1670
400
1570
91
590
120
Full
image &
Packtrack
HP- H1x
High Res
0.33mm (13mils)
175
LT-20
1050-
1450
400
1300
111
470
120
Full
image &
Packtrack
HP- H2x
Very High
Res
0.25mm (10mils)
155
LT-20
860-1110
250
960
147
395
85
Full
image &
Packtrack
Table 1 – Main Characteristics
In order to create multi-side or multi-point reading stations, the product line further includes the following models:
- XRF410N-xx0 MASTER: made up of two readers: one Master and one Slave 1. The Master must be connected directly to a CBX connection box through a CAB-DS-xx-S cable. The Slave is already connected to a QL100 which is provided with a CBL-1490 ID-NET network terminator. The other end of the QL100 must be connected to the CBX using a CBL-1480-xx cable to complete the ID-NET network.
- XRF410N-xx1 EXTENSION: made up of two Slave readers each connected to a QL100. These models must be connected to a Master XRF410N through the ID-NET network using a CBL-1480-xx cable to complete the ID-NET network.
One or more Extension XRF410N models can be chained together to extend the ID­NET network. When using the Extension models, the CBL-1490 ID-NET network terminator (present on the QL100 of the Slave reader on the Master XRF410N) must be transferred to the last slave on the last Extension XRF410N in the network.
XRF410N™ INSTALLATION
4
The complete list of XRF410N models is:
Description
Part Number
XRF410N-B00 2HD_MED RES_MASTER
937400028
XRF410N-B10 2HD_HI RES_MASTER
937400029
XRF410N-H00 2HD_HI PERF_MED RES_MASTER
937400030
XRF410N-H10 2HD_HI PERF_HI RES_MASTER
937400031
XRF410N-H20 2HD_HI PERF_VHI RES_MASTER
937400032
XRF410N-B01 2HD_MED RES_EXTENSION
937400033
XRF410N-B11 2HD_HI RES_EXTENSION
937400034
XRF410N-H01 2HD_HI PERF_MED RES_EXTENS
937400035
XRF410N-H11 2HD_HI PERF_HI RES_EXTENS
937400036
XRF410N-H21 2HD_HI PERF_VHI RES_EXTENS
937400037
The list of XRF410N accessories used to complete each installation is:
Required Accessories for XRF410N Base Performance Models
Description
1 Module
2 Modules
4 Modules
Part Number
XRF410N-B00 2HD_MED RES_MASTER
1 1 1
937400028
XRF410N-B01 2HD_MED RES_EXTENSION
- 1 3
937400033
CAB-ETH-M05 M12-IP67 ETHERNET CABLE (5M)
2 4 8
93A051348
CBL-1480-05 M12/5P MALE/FEMALE 5M IDNET
1 1 1
93A050051
CBL-1480-02 M12/5P MALE/FEMALE 2M IDNET
- 1 3
93A050050
CAB-DS05-S M12-IP67 TO CBX 5M
1 1 1
93A050060
CBX500 ATS-001 ASSEMBLY
1 1 1
93A301083
MEP-593 PHOTOCELL KIT
1 1 1
93ACC1791
OEK-2 OPTICAL ENCODER (CAB 10M+SPRING)
1 1 1
93ACC1770
BA400 M12 3P M. PANEL CONN. (EXT.POWER)
1 1 -
93ACC1853
CAB-PG-0002 VDC PWR PG120-IDNET 2M
1 1 -
93ACC1870
PG-120-K01 PWR SUPPLY KIT FOR M450 (EU)
1 1 -
93ACC0046
PWR-480B POWER UNIT 110/230VAC 24V
- - 1
93ACC0076
The OEK-2 Encoder is necessary when using PackTrack Operating Mode.
XRF410N™ INSTALLATION
5
Required Accessories for XRF410N High Performance Models
Description
1 Module
2 Modules
4 Modules
Part Number
XRF410N-H10 2HD_HI PERF_HI RES_MASTER
1 1 1
937400031
XRF410N-H11 2HD_HI PERF_HI RES_EXTENS
- 1 3
937400036
CAB-ETH-M05 M12-IP67 ETHERNET CABLE (5M)
2 4 8
93A051348
CBL-1480-05 M12/5P MALE/FEMALE 5M IDNET
1 1 1
93A050051
CBL-1480-02 M12/5P MALE/FEMALE 2M IDNET
- 2 6
93A050050
CAB-DS05-S M12-IP67 TO CBX 5M
1 1 1
93A050060
CBX500 ATS-001 ASSEMBLY
1 1 1
93A301083
CAB-MLP-05 MULTI LIGHTING POWER 5M
1 1 1
93A050084
MEP-593 PHOTOCELL KIT
1 1 1
93ACC1791
OEK-2 OPTICAL ENCODER (CAB 10M+SPRING)
1 1 1
93ACC1770
BA400 M12 3P M. PANEL CONN. (EXT.POWER)
1 - -
93ACC1853
CAB-PG-0002 VDC PWR PG120-IDNET 2M
1 - -
93ACC1870
PG-120-K01 PWR SUPPLY KIT FOR M450 (EU)
1 - -
93ACC0046
PWR-480B POWER UNIT 110/230VAC 24V
- 1 1
93ACC0076
The OEK-2 Encoder is necessary when using PackTrack Operating Mode.
In addition, the following single Spare Part replacement readers (relative to the specific XRF410N model) available for order;
Description
Part Number
MATRIX 410N XRF-B0x SPARE UNIT-REPLMNT
937400038
MATRIX 410N XRF-B1x SPARE UNIT-REPLMNT
937400039
MATRIX 410N XRF-H0x SPARE UNIT-REPLMNT
937400040
MATRIX 410N XRF-H1x SPARE UNIT-REPLMNT
937400041
MATRIX 410N XRF-H2x SPARE UNIT-REPLMNT
937400042
XRF410N™ INSTALLATION
6
INSTALLATION
GENERAL ID-NET CONFIGURATION
When using a single XRF410N-xx0 MASTER, no ID-NET network configuration is
necessary. This product leaves the factory pre-configured and the readers have respective Master and Slave 1 roles.
When using one or more XRF410N-xx1 EXTENSION(s) with the XRF410N-xx0
MASTER, the first step is to configure the ID-NET network because the EXTENSION Slave readers leave the factory with the unusable Slave 0 role (jolly).
The installation procedure for multi XRF readers is summarized below:
1. Mount the various XRF410Ns to the station frame.
2. Connect the ID-NET cabling, moving the ID-NET terminator to the last node in the network.
3. Run DL.CODE and connect to the Master reader.
4. Run “New Configuration - Multi Device. This will assign ID-NET addresses to all the Slaves in the network associating them with their respective serial numbers. Click Apply Changes.
CAUTION: XRF410N models have a default baudrate of 1 Mbs and are designed to be used in applications where the overall cable length does not exceed 30 meters. XRF410N models can only be connected in an ID-NET network to other XRF410N models; mixed networks with other types of Matrix readers are not allowed.
POWER REQUIREMENTS
Depending on the number of XRF410Ns used a different power supply will be required. The following table indicates which power supply to use for your application.
Number of Modules
XRF410N Model
1
2
3 to 4
5 to 8
Base (Bxx)
PG-120-K0x
PG-120-K0x
PWR-480B
PWR-480B
Hi Perf (Hxx)
PG-120-K0x
PWR-480B
PWR-480B
PWR-480B (x2)