![](/html/e4/e47e/e47ed754c0053720be63fda245c99b48d174bbda3e3ad0ccb0422a35b35d15f1/bg1.png)
APPLICATION NOTE
XRF410N™
Installation
Reference Software Versions:
1.4.0 and later
History
Added Electrical connection diagrams and
power supply table.
Added CAB-MLP-05 wiring info
Changed power supply table.
![](/html/e4/e47e/e47ed754c0053720be63fda245c99b48d174bbda3e3ad0ccb0422a35b35d15f1/bg2.png)
INTRODUCTION
XRF410N (named for its eXtended Reading Field), is a product developed mainly for T&L
applications with the goal of guaranteeing an extended horizontal field of view in order to fully
cover the entire width of a conveyor.
It is made up of two Matrix 410N™ model readers (optically pre-configured and not
modifiable). The readers are mounted onto a metal plate at a pre-defined distance from each
other (pitch), which depends on the optical model. They are also connected together
electrically by the ID-NET™ network.
The system therefore is pre-assembled and pre-configured to provide simpler installation.
Each M410N-XRF reader (including spare part readers) can only be used within an ID-NET
network in which at least one other reader is present. They cannot be used as Stand Alone
devices.
The various XRF410N models do not include CBX connection boxes or CBX connecting
cables so it is necessary to refer to the accessories list tables for the required material.
In terms of product performance there are two models:
- BP (Base Performance) for low cost applications and medium line speed. These
models have High Power Super Narrow Angle illuminators and use Image Cropping
(to avoid the presence of multiple packs inside the acquired image simultaneously).
- HP (High Performance) for high line speed applications. These models have Ultra
High Power illuminators and use full-frame images in PackTrack™ mode.
In addition, each of these is further divided into different optical models which are optimized
for different code resolutions, reading distances and field of view.
![](/html/e4/e47e/e47ed754c0053720be63fda245c99b48d174bbda3e3ad0ccb0422a35b35d15f1/bg3.png)
The following table summarizes the main characteristics of the various models:
Overlap
min
between
readers
[mm]
Table 1 – Main Characteristics
In order to create multi-side or multi-point reading stations, the product line further includes
the following models:
- XRF410N-xx0 MASTER: made up of two readers: one Master and one Slave 1. The
Master must be connected directly to a CBX connection box through a CAB-DS-xx-S
cable. The Slave is already connected to a QL100 which is provided with a CBL-1490
ID-NET network terminator. The other end of the QL100 must be connected to the
CBX using a CBL-1480-xx cable to complete the ID-NET network.
- XRF410N-xx1 EXTENSION: made up of two Slave readers each connected to a
QL100. These models must be connected to a Master XRF410N through the ID-NET
network using a CBL-1480-xx cable to complete the ID-NET network.
One or more Extension XRF410N models can be chained together to extend the IDNET network. When using the Extension models, the CBL-1490 ID-NET network
terminator (present on the QL100 of the Slave reader on the Master XRF410N) must
be transferred to the last slave on the last Extension XRF410N in the network.
![](/html/e4/e47e/e47ed754c0053720be63fda245c99b48d174bbda3e3ad0ccb0422a35b35d15f1/bg4.png)
The complete list of XRF410N models is:
XRF410N-B00 2HD_MED RES_MASTER
XRF410N-B10 2HD_HI RES_MASTER
XRF410N-H00 2HD_HI PERF_MED RES_MASTER
XRF410N-H10 2HD_HI PERF_HI RES_MASTER
XRF410N-H20 2HD_HI PERF_VHI RES_MASTER
XRF410N-B01 2HD_MED RES_EXTENSION
XRF410N-B11 2HD_HI RES_EXTENSION
XRF410N-H01 2HD_HI PERF_MED RES_EXTENS
XRF410N-H11 2HD_HI PERF_HI RES_EXTENS
XRF410N-H21 2HD_HI PERF_VHI RES_EXTENS
The list of XRF410N accessories used to complete each installation is:
Required Accessories for XRF410N Base Performance Models
XRF410N-B00 2HD_MED RES_MASTER
XRF410N-B01 2HD_MED RES_EXTENSION
CAB-ETH-M05 M12-IP67 ETHERNET CABLE (5M)
CBL-1480-05 M12/5P MALE/FEMALE 5M IDNET
CBL-1480-02 M12/5P MALE/FEMALE 2M IDNET
CAB-DS05-S M12-IP67 TO CBX 5M
OEK-2 OPTICAL ENCODER (CAB 10M+SPRING)
BA400 M12 3P M. PANEL CONN. (EXT.POWER)
CAB-PG-0002 VDC PWR PG120-IDNET 2M
PG-120-K01 PWR SUPPLY KIT FOR M450 (EU)
PWR-480B POWER UNIT 110/230VAC 24V
The OEK-2 Encoder is necessary when using PackTrack Operating Mode.
![](/html/e4/e47e/e47ed754c0053720be63fda245c99b48d174bbda3e3ad0ccb0422a35b35d15f1/bg5.png)
Required Accessories for XRF410N High Performance Models
XRF410N-H10 2HD_HI PERF_HI RES_MASTER
XRF410N-H11 2HD_HI PERF_HI RES_EXTENS
CAB-ETH-M05 M12-IP67 ETHERNET CABLE (5M)
CBL-1480-05 M12/5P MALE/FEMALE 5M IDNET
CBL-1480-02 M12/5P MALE/FEMALE 2M IDNET
CAB-DS05-S M12-IP67 TO CBX 5M
CAB-MLP-05 MULTI LIGHTING POWER 5M
OEK-2 OPTICAL ENCODER (CAB 10M+SPRING)
BA400 M12 3P M. PANEL CONN. (EXT.POWER)
CAB-PG-0002 VDC PWR PG120-IDNET 2M
PG-120-K01 PWR SUPPLY KIT FOR M450 (EU)
PWR-480B POWER UNIT 110/230VAC 24V
The OEK-2 Encoder is necessary when using PackTrack Operating Mode.
In addition, the following single Spare Part replacement readers (relative to the specific
XRF410N model) available for order;
MATRIX 410N XRF-B0x SPARE UNIT-REPLMNT
MATRIX 410N XRF-B1x SPARE UNIT-REPLMNT
MATRIX 410N XRF-H0x SPARE UNIT-REPLMNT
MATRIX 410N XRF-H1x SPARE UNIT-REPLMNT
MATRIX 410N XRF-H2x SPARE UNIT-REPLMNT
![](/html/e4/e47e/e47ed754c0053720be63fda245c99b48d174bbda3e3ad0ccb0422a35b35d15f1/bg6.png)
INSTALLATION
GENERAL ID-NET CONFIGURATION
When using a single XRF410N-xx0 MASTER, no ID-NET network configuration is
necessary. This product leaves the factory pre-configured and the readers have
respective Master and Slave 1 roles.
When using one or more XRF410N-xx1 EXTENSION(s) with the XRF410N-xx0
MASTER, the first step is to configure the ID-NET network because the EXTENSION
Slave readers leave the factory with the unusable Slave 0 role (jolly).
The installation procedure for multi XRF readers is summarized below:
1. Mount the various XRF410Ns to the station frame.
2. Connect the ID-NET cabling, moving the ID-NET terminator to the last node in the
network.
3. Run DL.CODE™ and connect to the Master reader.
4. Run “New Configuration - Multi Device. This will assign ID-NET addresses to all the
Slaves in the network associating them with their respective serial numbers. Click
Apply Changes.
CAUTION: XRF410N models have a default baudrate of 1 Mbs and are
designed to be used in applications where the overall cable length does not
exceed 30 meters. XRF410N models can only be connected in an ID-NET
network to other XRF410N models; mixed networks with other types of Matrix
readers are not allowed.
POWER REQUIREMENTS
Depending on the number of XRF410Ns used a different power supply will be required. The
following table indicates which power supply to use for your application.