Datalogic TC1100 User Manual

EAN/UPC disable AA0
68
(
)
(
)
(
)
(
)
EAN 8/EAN 13/UPC A/UPC E enable AA1
EAN 8/EAN 13 enable AA3
UPC A/UPC E enable AA4
EAN 8 enable AAG0
EAN 13 enable AAH0
UPC A enable AAI0
UPC E enable AAJ0
Code 39 disable AB0 Code 39 Standard enable AB11xxyy
Code 39Full ASCII enable AB21xxyy
Code 2/5 family disable AC0 Interleaved 2/5 enable AC11xxyy
Normal 2/5 5 bars enable AC21xxyy
Industrial 2/5 (IATA) enable AC31xxyy
Matrix 2/5 3 bars enable AC41xxyy
Codabar family disable AD0 Codabar standard enable AD111xxyy
Code 128 family disable AI0
Code 128 enable AI11 xxyy control without transmission of check digit EAN 128 enable AI21 xxyy control without transmission of check digit Code Length AILxxyy
Code 93 family disable AK0 Code 93 enable AK1 xxyy control without transmission of check digit PDF417 disable AR0 PDF417 enable AR1 Pharmacode disable AQ0
Pharmacode enable AQ1xxyy
Overflow ratio AQAzz
xxyy = ASCII numbers that define:
AA5 AA8
AAK AAL AA6
AAM AAN AA7
AAG1
AAH1
AAI1
AAJ1
AB12xxyy AB13xxyy
AB22xxyy
AC12xxyy AC13xxyy
AC22xxyy AC23xxyy
AC32xxyy AC33xxyy
AC42xxyy AC43xxyy
AD112xxyy AD121xxyy AD122xxyy AD212xxyy
AQ2xxyy
without ADD ON with ADD ON with and without ADD ON without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5 without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5 check digit transmission disable check digit transmission enable check digit transmission disable check digit transmission enable check digit transmission disable check digit transmission enable check digit transmission disable check digit transmission enable
no check digit control check digit control and transmission check digit control without transmission no check digit control check digit control and transmission
no check digit control check digit control and transmission check digit control without transmission no check digit control check digit control and transmission check digit control without transmission no check digit control check digit control and transmission check digit control without transmission no check digit control check digit control and transmission check digit control without transmission
no start/stop character equality control - nor transmission no start/stop character equality control but transmission start/stop character equality control but no transmission start/stop character equality control and transmission ABC Codabar no start/stop character equality control but transmission
forward code tx direction reverse code tx direction
xx = min. acceptable code length yy = max. acceptable code length zz = overflow ratio value The minimum code length must always be less than or equal to the maximum.
For more detailed information on the TC1100 programmability and complete parameter list, please refer to the TC1100 Reference Manual.
N24
CODE SELECTION
821000606 (Rev. H)
TC1100
CCD Scan Engine Quick Guide
The TC1100 is a linear CCD Scan Engine for OEM applications. It is available in two different versions:
Model Description Order Number
TC1100-0100 CCD scan engine for linear codes 939501000 TC1100-0200 CCD scan engine for linear and PDF417 939501010
Technical Specifications
Power supply Consumption 1.5 W Interfaces RS232, WEDGE, PEN Emulation Max Scans/sec 270 Max resolution 0,076mm (3mils) Readable codes:
Default Configuration
Power Save 270 scans/sec, sleep disabled, standby disabled Reading Parameters On-Line Code Selection
Enabled codes
(Only TC1100-0200)
Data Format Code ID disabled, Header = <STX>, Terminator = <CR> <LF>, no Field Adjustment, Code
Decoding Parameters Ink spread enabled, overflow control enabled, interdigit control enabled, Puzzle Solver™
Enabled interface RS232, 9600, N, 8, 1, no handshaking, ACK/NAK disabled, RX timeout 100 ms, FIFO
Reading Diagrams
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320
160
140
120
100
80
0.20 mm
60
40
20
0
-20
-40
-60
-80
-100
-120
0.13 mm
-140
5 mils
-160
Reading Diagram TC1100-0100 (code 39) Reading Diagram TC1100-0200 (PDF417)
0.20 mm
5 Vdc ± 5%
EAN/UPC, Code 39, 2/5 family, Codabar, Code 128, EAN 128, ISBT 128, Code 93, pharmaceutical codes, Delta IBM, Code 16K, Code 49, (Telepen, MSI/Plessey, Pharmacode only TC1100-0100), (Codablock-A, Codablock-F Std, Codablock-F EAN, PDF417 only TC1100-0200)
Interleaved 2 of 5: Check Digit transmitted, length: min 4, max 99
Code EAN8, EAN13, UPCA, UPCB: without ADD ON, Check Digit transmitted, no conversions
Code 39: length: min 1, max 99
Code 128: Check Digit not transmitted, length: min 1, max 99
PDF417
length TX disabled, character replacement disabled, No Read Character = <CAN>
disabled, decoding safety = 1 read
enabled, inter-character delay disabled
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
90
80
70
60
50
40
30
20
10
0
10
-
-20
-30
-40
-50
-60
-70
-80
-90
8 mils
0.30 mm
12 mils
0.50 mm
20 mils
0.17 mm
(6.6 mils)
0.25 mm
(10 mils)
0.38 mm
(15 mils)
Electrical Connections
J1
1 SGND Serial Ground 2 OUT ­3 OUT+ 4 EXT BEEPER External beeper connection 5 CTS Clear to send 6 RX Reception 7 RTS Request to send 8 TX Transmission
J2
1 VCC+ +5Vdc 2 GND GND 3 CLKOUT 4 DATAOUT 5 DATAIN_WAND 6 CLKIN 7 EXT TRIG+ 8 EXT TRIG-
See Figure 1
See Figure 2
Physical Dimensions
Width 63 mm 2.48 inches Length 60.5 mm 2.38 inches Height 27 mm 1.06 inches
Ø2.7
[Ø0.11] n°4
40.5
[1.59]
63
[2.48]
Connectors:
HIROSE
Mod. DF13-8p-1.25V
1
J1
1
J2
[0.10]
18
[0.71]
Led Status
Led2 ON = Power supply ON Led2 OFF= Power supply OFF
Led1 ON=
Led1 OFF= Miss read
Good read (the led will remain ON until status changes)
mm
[ in.]
[1.97]
Led2 Led1
2.5
[0.10]
57
[2.24]
28.5
[1.12]
Horizontal Optical Axis
63
[2.48]
2.5
[0.10]
25.7
[1.01]
Return to RS232 Interface
TC1100
J1
3
2
USER INTERFACE
OUT +
OUT -
Vext 40 Vdc max
Ì$+CP0$-$Î
Veritcal Optical Axis
12.2
[0.48]
Figure 1 - Output Connection (Good Read). Example NPN
For WEDGE Users
Vext
TC1100
+ 5V
J2
7
8
Vext
EXT TRIG+
EXT TRIG-
30 Vdc max.
EXTERNAL TRIGGER
V
Signal
TC1100 EXTERNAL TRIGGER
+ 5V
J2
7
8
EXT TRIG+
EXT TRIG-
30 Vdc max.
V
Signal
Ground
Input NPN command using external power Input PNP command using external power
J2
Vcc 5Vdc
+ 5V
1
EXT TRIG+
7
8
EXT TRIG-
2
GND
EXTERNAL TRIGGERTC1100
V
Ground
Signal
+ 5V
J2
Vcc 5Vdc
1
7
EXT TRIG+
8
2
Input NPN command using TC1100 power Input PNP command using TC1100 power
Figure 2 - Trigger Connections
2.5
50
60.5
[2.38]
Basic Commands for TC1100
The TC1100 default configuration can be changed by receiving commands through the RS232 Interface. The command syntax is given below with an example.
Command syntax
$+ Command(s) $- <CR> the new setting will be definitive (stored in FLASH EPROM)
Example:
Enter configuration environment
Serial On-Line
Commands:
Operating Mode
Baud Rate = 19200
Multiple command programming sequence:
BK0 $- CR
$+
AC410132CD7
Matrix 2/5 3 bars: no check digit,
variable length code from 1 to 32 characters
Carriage return character (0D Hex.)
Exit and save new configuration
EXT TRIG-
GND
EXTERNAL TRIGGERTC1100
V
Signal
Ground
OPERATING MODES
On-line BK1 Serial On-line BK0 Automatic BK3 Automatic / Lighting System Standby BK2 To enter in Test mode #+Dstat1<CR> (does not require $+ or $-) To exit Test mode #+Dstat0<CR> (does not require $+ or $-)
GENERAL FEATURES
RS232 interface selection CP0 RS232 Baud Rate CD0 for 150 Baud up to CD8 for 38400 Baud WEDGE AT CP500 WEDGE Notebook CP505 Keyboard Nationality FJ7 Belgian
CCD Scan Rate BT0 67 scans/sec
Puzzle Solver AU1 enable AU0 disable Ink Spread AX1 enable AX0 disable Decoding safety ED0 1 read
To restore the default configuration $+$*<CR> (does not require $-) To get configuration from the reader $+$& <CR> (does not require $-)
FJ4 English FJ2 French FJ3 German
BT1 135 scans/sec BT2 270 scans/sec
ED1 2 reads
FJ1 Italian FJ6 Spanish FJ5 Swedish FJ0 USA
ED2 3 reads ED3 4 reads
Loading...