
OVERALL DIMENSIONS
Fig.11
Shows all the overall mechanical dimensions of any possible configuration.
AVAILABLE MODELS
MODEL DESCRIPTION ORDER N°
SG-LP SG-LP Laser pointer 95ASE5590
DECLARATION OF CONFORMITY
DATALOGIC AUTOMATION declare under our sole responsibility that these products are conform to the 2004/108/CE,
Directive and successive amendments
WARRANTY
DATALOGIC AUTOMATION warrants its products to be free from defects.
DATALOGIC AUTOMATION will repair or replace, free of charge, any product found to be defective during the warranty
period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of DATASENSOR products.
DATALOGIC AUTOMATION Via S. Vitalino 13
40012 Calderara di Reno - Bologna - Italy
Tel: +39 051 3147011 Fax: +39 051 3147453
www.automation.datalogic.com e-mail: info.automation@datalogi c.com
DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
DATALOGIC AUTOMATION reserves the right to make m odifications and improvements without prior notification.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U.
Operations Office Via Lavino 265
40050 Monte S.Pietro - Bologna – Italy
Tel: +39 051 6765611 Fax: +39 051 6759324
856001500 Rev.00 © Copyright Datalogic 2009
SG-LP SERIES
Laser pointer
GENERAL INFORMATION
Thanks to its completely new housing and fixing system SG-LP laser pointer can be installed in all safety
light curtains profiles of SE, SG2, SG4 and SG Body series. Thanks to a specially designed CAM fixing
equipment the laser pointer can be inserted into one of the two lateral grooves either from the top or from
the side, depending on which kind of fixing brackets have been used to mount the safety light curtain
(standard “L” or TOP-BOTTOM Rotating ones).
One top and one lateral fixing brackets, together with two tightening knobs, allow to adjust SG-LP laser
pointer’s position in both transversal and longitudinal directions and to have it constantly centred respect
light curtain’s optical axis, independently from housing width.
HIGLIGHTS
TYPICAL APPLICATIONS
SG-LP laser pointer is advised to be used to ease TX and RX mechanical alignment process in the following
installation conditions:
PACKAGE CONTENTS
The package contains the following items:
a) Laser pointer (1 pcs)
b) Mounting cams ensemble (1 pcs)
c) Transversal adjustment bracket (1 pcs)
d) Vertical mounting bracket (1 pcs)
e) User manual (1 pcs)
To be used to help the mechanical alignment of TX and RX unit of safety light curtain;
Suitable for all SE, SG2, SG4 and SG Body profiles;
Installation performed through one of two lateral grooves of the safety light curtain housing;
Insertion into the groove either from the top or from the side;
Transversal and longitudinal adjustment, thanks to one top and one lateral fixing brackets,
together with two tightening knobs
Mutli-beam body/access protection safety light curtain whose operating distance is more than
50m;
Mutli-beam body/access protection safety light curtain installed with deviating mirrors to perform
perimetric protections;
Finger or hand protection safety light curtains installed with deviating mirrors to protect different
sides of a machine.
Nuts and bolts
4x8 DIN464 Knurled screw (4 pcs)
1

SAFETY PRECAUTIONS
NOTE: The SE-SP laser pointer uses a red laser light beam tha t can be potentiall y dangerous to the
human eye.
Do not stare directly at the light beam.
The laser pointer is powered by two 1.5 V AAA type batteries, take care to respect right polarity.
Battery replacement:
With a common cross head screw driver remove the 2 TSP UNI
7688 M2,5x8 screws from bottom closing cap then remove it to
have access to the battery box.; put off the battery box, extract the
two batteries and replace with new ones. Place the battery box in its
place, close with the cap and firmly tighten the screws (Fig. 1).
Exhausted batteries are designated for separate collection at an
appropriate collection point.
Do not dispose of as household waste.
For more information, contact the local authorities in charge of
waste management.
Fig.1
INSTRUCTIONS
INSTALLATION
Install the emitting and receiving units of the SE/SG series safety device in the defined positions (refer to
MECHANICAL MOUNTING chapter of the safety light curtain instructions manual). The use of floor
stands is recommended, verifying that they are firmly fixed and that their axis is perpendicular to the floor.
SG-LP laser pointer is installed on SG and SE safety light curtains profiles using one of the two lateral
grooves. Depending on which kind of fixing bracket is used, laser pointer can be mounted side way or
slotted from the top. Side mounting is compulsory when the accessory is installed on SG curtains with
TOP-BOTTOM rotating brackets.
2