Datalogic QuickScan Mobile, QuickScan M2130 Quick Reference Manual

QuickScan™ Mobile
General Purpose Handheld
Linear Imager Bar Code Reader with
Datalogic’s STAR Cordless System™
Quick Reference Guide
959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140
©2008-2014 Datalogic, Inc.
An Unpublished Work - All rights reserved. No part of the contents of this docu­mentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic ADC"). Owners of Data­logic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business pur­poses. Purchaser shall not remove or alter any proprietary notices, including copy­right notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation. Should future revisions of this manual be published, you can acquire printed ver­sions by contacting your Datalogic representative. Electronic versions may either be downloadable from the Datalogic website (www.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other brand and product names may be trademarks of their respective owners.
Patents
This product may be covered by one or more of the following patents:
Utility patents: EP0789315B1; EP0851378B1; EP0895175B1; EP1128314B1; EP1164536B1; EP1205871B1; EP1205873B1;
EP1942442B1; US5992740; US6305606; US6517003; US6712271; US6834806; US6871785; USRE41349
Additional patents pending.
Table of Contents
Using Quickscan™ Mobile Reader and Cradle ............................................... 1
Reading Angle ......................................................................................... 2
Hands-Free Use ...................................................................................... 2
Using Your QuickScanTM Mobile Reading System ............................. 3
Installing the Battery ...................................................................................... 3
Changing the Batteries .......................................................................... 5
Connecting the QuickScan Mobile ................................................................. 7
System Connections ............................................................................... 7
QuickScan Mobile Cradle Configuration ..................................................... 10
Serial/USB-COM Configuration ........................................................... 10
QuickScan Mobile Reader Configuration .................................................... 10
Interface Selection ........................................................................................ 12
USB Interface Configuration ................................................................ 12
START-UP ...................................................................................... 12
USB Interface Selection ................................................................................ 13
RS-232 Interface Selection .......................................................................... 14
Wedge Interface Selection ........................................................................... 15
USB / Wedge Keyboard Nationality .................................................... 18
IBM46xx Interface Selection ....................................................................... 19
Pen Interface Selection ........................................................................ 20
Operating Test ............................................................................................... 21
Reader Default Configuration ...................................................................... 22
Cradle Default Configuration ....................................................................... 23
Technical Features ........................................................................................ 24
Compliance .................................................................................................... 26
Power Supply ......................................................................................... 26
FCC Compliance ..................................................................................... 26
LED Class ............................................................................................... 27
Radio Compliance ................................................................................. 27
WEEE Statement .................................................................................. 30
Datalogic ADC Limited Factory Warranty ................................................... 31
Ergonomic Recommendations .................................................................... 32
Services and Support .................................................................................... 33
Products......................................................................................... 33
Service & Support ......................................................................... 33
Contact Us ..................................................................................... 33
NOTES
Quick Reference Guide
1
Using Quickscan™ Mobile Reader and Cradle
The QuickScan Mobile reader and cradle build a Cordless Reading System for the collection, decoding and transmission of barcode data.
Standard models can be connected to a Host PC through a USB, RS-232, Wedge or Pen emulation cable. All models are suited for single-cradle layouts.
The LEDs signal the QuickScan Mobile cradle status, as described in the following table:
LED BEEPER STATUS
Power on / Data
-
Yellow On = QuickScan
®
Mobile cradle is powered. Yellow Blinking = the cradle receives data and com­mands from the Host or the reader.
Charging - Red On = the battery charge is in progress. Charge com­pleted
- Green On = the battery is completely charged.
Alternating red/green
Repetitive
beep
Charging out of temperature range, over-current or over-voltage conditions
Charge completed (green LED)
Charging (red LED)
Power on / Data (yellow LED)
2 QuickScan™ Mobile
Reading Angle
QuickScanTM Mobile readers automatically scan barcodes at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code.
Successful scanning is obtained by tilting the reader with respect to the barcode to avoid direct reflections, which could impair the reading performance. See the figures below.
Successful reading is indicated by an audible tone.
OK Not Recommended
Hands-Free Use
When using the QuickScan Mobile on the cradle, remember to lock the reader by pushing up the locking system as indicated in the following figure.
Good read LED
Installing the Battery
Quick Reference Guide 3
Using Your QuickScanTM Mobile Reading System
Follow the procedure below to start using your QuickScan Mobile reading system:
1. Connect a QuickScan Mobile cradle to the Host. For installation and connection information see "System Connections" on page 7.
2. Insert the QuickScan Mobile reader into the cradle to start the battery charging.
A full charge of the Lithium battery takes 3.5 – 6 hours.
For hands-free use, you can immediately begin using the reader, since it is powered by the cradle.
3. Configure the QuickScan Mobile reader.
4. Configure the QuickScan Mobile cradle. Reference "QuickScan Mobile
Cradle Configuration" on page 10.
Installing the Battery
To install, charge and/or do any other action on the battery, follow the instructions in this manual.
Battery Safety
To achieve the best battery life, it is recommended to perform a full battery charge before using the reader in handheld mode.
Datalogic recommends annual replacement of rechargeable bat­tery packs to ensure maximum performance.
WARNING
Do not discharge the battery using any device except the scanner. When the battery is used in devices other than the designated product, it may damage the battery or reduce its life expectancy. If the device causes an abnormal current to flow, it may cause the battery to become hot, explode or ignite and cause serious injury.
Lithium-ion battery packs may get hot, explode or ignite and cause serious injury if exposed to abusive conditions. Be sure to follow the safety warnings that follow:
• Do not place the battery pack in fire or heat.
• Do not connect the positive terminal and negative terminal of the battery pack to each other with any metal object (such as wire).
• Do not carry or store the battery pack together with metal objects.
Installing the Battery
4 QuickScan™ Mobile
As with other types of batteries, Lithium-Ion (LI) batteries will lose capacity over time. Capacity deterioration is noticeable after one year of service whether the battery is in use or not. It is difficult to precisely predict the finite life of a LI battery, but cell manufacturers rate them at 500 charge cycles. In other words, the batteries should be expected to take 500 full discharge / charge cycles before needing replacement. This number is higher if partial discharging / recharging is adhered to rather than full / deep discharging.
WARNING
• Do not pierce the battery pack with nails, strike it with a hammer, step on it or otherwise subject it to strong impacts or shocks.
• Do not solder directly onto the battery pack.
• Do not expose the battery pack to liquids, or allow the battery to get wet.
• Do not apply voltages to the battery pack contacts.
In the event the battery pack leaks and the fluid gets into your eye, do not rub the eye. Rinse well with water and immediately seek medical care. If left untreated, the battery fluid could cause damage to the eye.
CAUTION
Always charge the battery at 32° – 113°F (0° - 45°C) temperature range.
Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller. The use of any other power supplies can damage the device and void your war­ranty.
Do not disassemble or modify the battery. The battery contains safety and protection devices, which, if damaged, may cause the battery to generate heat, explode or ignite.
Do not place the battery in or near fire, on stoves or other high temperature locations.
Do not place the battery in direct sunlight, or use or store the bat­tery inside cars in hot weather. Doing so may cause the battery to generate heat, explode or ignite. Using the battery in this manner may also result in a loss of performance and a shortened life expectancy.
Do not place the battery in microwave ovens, high-pressure con­tainers or on induction cookware.
Immediately discontinue use of the battery if, while using, charging or storing the battery, the battery emits an unusual smell, feels hot, changes color or shape, or appears abnormal in any other way.
CAUTION
Do not replace the battery pack when the device is turned on. Do not remove or damage the battery pack’s label. Do not use the battery pack if it is damaged in any part. Battery
pack usage by children should be supervised.
Installing the Battery
Quick Reference Guide 5
The typical manufacturer advertised useful life of LI batteries is one to three years, depending on usage and number of charges, etc., after which they should be removed from service, especially in mission critical applications. Do not continue to use a battery that is showing excessive loss of capacity, it should be properly recycled / disposed of and replaced. For most applications, batteries should be replaced after one year of service to maintain customer satisfaction and minimize safety concerns.
Collect and recycle waste batteries separately from the device in comply with European Directive 2006/66/EC, 2011/65/EU, 2002/96/EC and 2012/19/EU and
subsequent modifications, US and China regulatory and others laws and
regulations about the environment.
Changing the Batteries
To change the battery of your reader, you must:
1. Unscrew the battery cover screw (Figure 1-A)
2. Unplug the white connector and remove the old battery (Figure 1-B)
3. Insert the new battery and plug in the white connector (Figure 1-C)
Figure 1. Changing the Battery
When inserting the new battery into the handle be sure to posi­tion the battery and the connector as shown below.
A
B
C
Installing the Battery
6 QuickScan™ Mobile
4. Re-insert the cover in the handle, and replace the screw to secure it.
Do not incinerate, disassemble, short terminals or expose to high temperature. Risk of fire, explosion. Use specified charger only. Risk of explosion if the battery is replaced by an incorrect type. Dispose of the batteries as required by the relevant laws in force.
WARNING
Connecting the QuickScan Mobile
Quick Reference Guide 7
Connecting the QuickScan Mobile
You can connect the QuickScanTM Mobile cradle to the Host through the dedicated connector, using the cable corresponding to the desired interface type.
1. Connect the appropriate interface cable to the cradle by simply plugging it into the Host connector on the base of the cradle.
Figure 2. QuickScan Mobile Cradle - Bottom View
2. To disconnect the cable, insert a paper clip or other similar object into the hole corresponding to the connector on the base of the cradle. Push down on the clip while unplugging the cable. Refer to the following fig­ure.
Figure 3. Disconnecting the cable
System Connections
RS-232
CAUTION
Connections should always be made with power off!
Connecting the QuickScan Mobile
8 QuickScan™ Mobile
USB
IBM USB POS
WEDGE (Only for Quickscan M2 type:130)
WEDGE (Only for QUICKSCAN M2 TYPE:130)
Connecting the QuickScan Mobile
Quick Reference Guide 9
PEN
IBM PORT9B / IBM Port 5B (Only for QUICKSCAN M2 TYPE:110)
CAB-445
CAB-446
QuickScan Mobile Cradle Configuration
10 QuickScan™ Mobile
QuickScan Mobile Cradle Configuration
The QuickScan Mobile cradle configuration can be performed in two ways: either by sending configuration strings from the Host via the RS-232 or USB-COM interface or by reading configuration barcodes with the reader.
Serial/USB-COM Configuration
By connecting the QuickScan Mobile cradle to a PC through an RS-232 or USB cable (only USB-COM interface) it is possible to send configuration strings from the PC to the reader. Using this method you can also send new configuration strings from the PC to the reader or upgrade application software onto the reader.
QuickScan Mobile Reader Configuration
When the QuickScan Mobile cradle is connected and powered, configure the QuickScan
®
Mobile reader by reading the following codes in the given sequence
and follow the instructions.
For the numeric code selection of step 3, use the table at the end of this Quick Reference Guide.
1.
Restore QuickScan Mobile default
Ì$+$*oÎ
2.
Enter configuration
Ì$+;Î
3.
Set Radio Address
ÌRF8Î
+
four digits for the QuickScan Mobile Address
(from 0000 to 1999).
All readers used in the same area must have different addresses.
4.
Exit and Save configuration
Ì$-?Î
QuickScan Mobile Reader Configuration
Quick Reference Guide 11
YOUR READER IS NOW READY TO READ CODES.
5.
Read the Bind code to pair the QuickScan
TM
Mobile reader to the
cradle.
The reader is dedicated to the cradle. Any previously bound reader will be excluded.
Bind
Ì$+RN0$-IÎ
The green LED on the QuickScan Mobile reader will blink: the reader is ready to be positioned onto the cradle.
6. Firmly position the reader onto the cradle within 10 seconds, a beep will be emitted, signaling that the QuickScan Mobile cradle has been paired to the QuickScan Mobile reader.
7. Now you can configure the QuickScan Mobile cradle by reading configuration barcodes.
Interface Selection
12 QuickScan™ Mobile
Interface Selection
Follow the procedure to configure the interface required by your application.
Multi-standard interface models:
·USB Interface
· RS-232 Interface
·Wedge Interface
·Pen Interface
USB Interface Configuration
The USB interface is compatible with:
- Windows 98 (and later)
- Mac SO 8.0 (and later)
- 4690 Operating System
START-UP
As with all USB devices, upon connection, the Host performs several checks by communicating with the cradle. Before the cradle is ready, the correct USB driver must be loaded.
For all systems, the correct USB driver for the default USB-KBD interface is included in the Host Operating System and will either be loaded automatically or will be suggested by the O.S. and should therefore be selected from the dialog box (the first time only).
You can now read codes with the associated QuickScan Mobile reader. At this point you can read the USB interface configuration code according to your application. Load drivers from the O.S. (if requested). When configuring the USB-COM interface, the relevant files and drivers must be installed from the USB Device Installation software which can be downloaded from the web site: http://www.datalogic.com
.
The cradle is ready.
Successive start-ups will automatically recognize the previously loaded drivers.
Connect cradle to Host
Select desired USB interface code
(USB-KBD is default)
Load drivers
(if requested)
Load drivers
(if requested)
USB Interface Selection
Quick Reference Guide 13
USB Interface Selection
* When configuring USB-COM, the relevant files and drivers must be installed from the
USB Device Installation software, which can be downloaded from the web site http://
www.datalogic.com.
Select one keyboard nationality code from the table at page 18.
USB-KBD (default)
Ì$+UA03$-:Î
USB-KBD-ALT-MODE
Ì$+UA04$-@Î
USB-KBD-APPLE
Ì$+UA05$-FÎ
USB-COM*
Ì$+UA02$-4Î
USB-IBM-Table Top
Ì$+UA00$-(Î
USB-IBM-Hand Held
Ì$+UA01$-.Î
RS-232 Interface Selection
14 QuickScan™ Mobile
RS-232 Interface Selection
Read the QuickScanTM Mobile cradle restore default code, and then read the interface selection code for your application:
RESTORE QUICKSCAN MOBILE CRADLE DEFAULT
Ì$+RX0$-qÎ
RS-232 Interface
Standard
Ì$+CP0$-$Î
POS TERMINALS
Nixdorf Mode A
Ì$+CM2EC0$->Î
Fujitsu
Ì$+CM1$-ÈÎ
ICL Mode
Ì$+CM0$-ÃÎ
Wedge Interface Selection
Quick Reference Guide 15
Wedge Interface Selection
Read the QuickScanTM Mobile cradle restore default code, then read the interface selection code for your application:
RESTORE QUICKSCAN MOBILE CRADLE DEFAULT
Ì$+RX0$-qÎ
This feature is only available for Quickscan M2 Type:130
WEDGE INTERFACE
IBM AT or PS/2 PCs
Ì$+CP500$-aÎ
IBM XT
Ì$+CP503$-vÎ
PC Notebook
Ì$+CP505$-ÈÎ
IBM SURE1
Ì$+CP506$-$Î
IBM Terminal 3153
Ì$+CP504$-}Î
Wedge Interface Selection
16 QuickScan™ Mobile
WEDGE INTERFACE (CONTINUED)
IBM Terminals 31xx, 32xx, 34xx, 37xx:
To select the interface for these IBM Terminals, read the correct KEY TRANSMISSION code. Select the KEYBOARD TYPE if necessary (default = advanced keyboard).
KEY TRANSMISSION MODE
make-only keyboard
Ì$+CP502$-oÎ
make-break keyboard
Ì$+CP501$-hÎ
KEYBOARD TYPE
advanced keyboard
Ì$+FK1$-ÉÎ
typewriter keyboard
Ì$+FK0$-ÄÎ
ALT MODE
The following interface selection allows barcodes sent to the PC to be interpreted correctly independently from the Keyboard Nationality used.
You do not need to make a Keyboard Nationality selection.
(default = Num Lock Unchanged)
Make sure the Num Lock key on your keyboard is ON.
IBM AT - ALT mode
Ì$+CP507$-+Î
PC Notebook - ALT mode
Ì$+CP508$-2Î
Wedge Interface Selection
Quick Reference Guide 17
WEDGE INTERFACE (CONTINUED)
WYSE TERMINALS
ANSI Keyboard
Ì$+CP509$-9Î
PC Keyboard
Ì$+CP510$-gÎ
ASCII Keyboard
Ì$+CP511$-nÎ
VT220 style Keyboard
Ì$+CP514$-ÇÎ
DIGITAL TERMINALS
VT2xx/VT3xx/VT4xx
Ì$+CP512$-uÎ
APPLE
APPLE ADB Bus
Ì$+CP513$-|Î
Wedge Interface Selection
18 QuickScan™ Mobile
USB / Wedge Keyboard Nationality
USB/Wedge interface users should select one of the following KEYBOARD NATIONALITY codes.
Belge
Ì$+FJ7$-8Î
Deutsch
Ì$+FJ3$-$Î
English (UK)
Ì$+FJ4$-)Î
Español
Ì$+FJ6$-3Î
Français
Ì$+FJ2$-ÊÎ
Italiano
Ì$+FJ1$-ÅÎ
Svenskt
Ì$+FJ5$-.Î
USA
Ì$+FJ0$-|Î
The following Keyboard Nationality selection is only valid for IBM AT compatible PCs:
Japanese
Ì$+FJ8$-=Î
IBM46xx Interface Selection
Quick Reference Guide 19
IBM46xx Interface Selection
Read the QuickScanTM Mobile cradle restore default code, then read the interface selection code for your application:
RESTORE QUICKSCAN MOBILE CRADLE DEFAULT
Ì$+RX0$-qÎ
This feature is only available for Quickscan M2 Type:110
IBM 46XX TERMINALS
PORT 9B
4501 Protocol
Ì$+CP800$-pÎ
(typical)
1520 Protocol
Ì$+CP801$-wÎ
IBM 46XX TERMINALS
PORT 5B
1520 Protocol
Ì$+CP801$-wÎ
(typical)
4501 Protocol
Ì$+CP800$-pÎ
IBM46xx Interface Selection
20 QuickScan™ Mobile
Pen Interface Selection
Read the QuickScanTM Mobile cradle restore default code, then read the interface selection code for your application:
RESTORE QUICKSCAN MOBILE CRADLE DEFAULT
Ì$+RX0$-qÎ
PEN INTERFACE
Ì$+CP6$-BÎ
Operating Test
Quick Reference Guide 21
Operating Test
Read the TEST codes below.
EAN-8
EAN-13
Code 39 (Normal)
Code 128
Interleaved 2 of 5
YOUR SYSTEM IS READY TO READ CODES AND TO SEND THE DATA TO THE HOST.
To change the defaults, refer to the "QuickScan
TM
Mobile Reference Manual", part number 820001971, or to the Datalogic Aladdin™ Configuration program, both downloadable from the website.
1234 5670
1 234567 000992
17162
Code 39 (Normal)
test
0123456784
Reader Default Configuration
22 QuickScan™ Mobile
Reader Default Configuration
DATA FORMAT
code identifier disabled (enabled for POS terminals), field adjustment disabled, code length tx not transmitted, character replacement disabled, address stamping disabled; address delimiter disabled
POWER SAVE
sleep state/USB suspend disabled, enter sleep timeout = 0.6 sec
READING PARAMETERS
hand-held operation = hardware trigger, stand operation = automatic, trigger active level, no timeout, Flash On = 1 sec, Flash Off = 0.6 sec, one read per cycle, safety time 0.5 sec, beeper intensity high, tone 2, beeper type monotone, beeper length short, good read spot duration medium, automatic operation aiming light enabled
DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit control enabled, Puzzle Solver™ disabled, decoding safety = one read
CODE SELECTION
Enabled codes
· EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
· Interleaved 2/5
check digit control and transmission, variable length code; 4-99 characters
· Standard Code 39
no check digit control, variable length code; 1-99 characters
· Code 128
variable length code; 1-99 characters
· EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI, Plessey,
Telepen, Delta IBM, Code 11, Code 16K, Code 49, GS1 DataBar™ (GS1 DataBar™ includes the following symbologies: RSS­14, RSS-14 Stacked, RSS Expanded and RSS Limited).
ADVANCED FORMATTING PARAMETERS
concatenation disabled, no advanced formats defined
RADIO PARAMETERS
radio protocol timeout = 2 seconds, power-off timeout = 4 hours, single store disabled, beeper control for radio response = normal
Cradle Default Configuration
Quick Reference Guide 23
Cradle Default Configuration
USB DEFAULT SETTINGS
DATA FORMAT: code identifier disabled, code length not transmitted, character replacement disabled, address stamping disabled, address delimiter disabled.
USB KEYBOARD: USA keyboard, FIFO enabled, inter-character and inter-code delays disabled.
USB COM: handshaking disabled, delay disabled, rx timeout 5 sec., ack/nack disabled, FIFO enabled, serial trigger lock disabled. Default Headers and Terminators for each USB mode:
- USB-KBD: no header, terminator = ENTER
- USB-KBD-ALT-MODE: no header, terminator = CR
- USB-COM: no header, terminator = CR-LF
- USB-IBM-TABLE TOP: not applicable
- USB-IBM-HAND HELD: not applicable
RS-232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, handshaking disabled, ACK/NACK disabled, FIFO enabled, inter-character delay disabled, 5 sec. rx timeout, serial trigger lock disabled.
DATA FORMAT: code identifier disabled, code length not transmitted, no header, terminator = CR-LF, character replacement disabled, address stamping disabled, address delimiter disabled.
RS-232 Nixdorf DEFAULT SETTINGS
9600 baud, odd parity, 8 data bits, 1 stop bit, handshaking hardware (RTS/ CTS), ACK/NACK disabled, FIFO disabled, inter-character delay disabled, 9.9 sec. rx timeout, serial trigger lock disabled.
DATA FORMAT: code identifier enabled, code length not transmitted, no header, terminator = CR, character replacement disabled, address stamping disabled, address delimiter disabled.
RS-232 Fujitsu DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, handshaking disabled, ACK/NACK disabled, FIFO enabled, inter-character delay disabled, 2 sec. rx timeout, serial trigger lock disabled.
DATA FORMAT: code identifier enabled, code length not transmitted, no header, terminator = CR, character replacement disabled, address stamping disabled, address delimiter disabled.
RS-232 ICL DEFAULT SETTINGS
9600 baud, even parity, 8 data bits, 1 stop bit, handshaking RTS always on, ACK/NACK disabled, FIFO enabled, inter-character delay disabled,
9.9 sec. rx timeout, serial trigger lock disabled.
Technical Features
24 QuickScan™ Mobile
DATA FORMAT: code identifier enabled, code length not transmitted, no header, terminator = CR, character replacement disabled, address stamping disabled, address delimiter disabled.
WEDGE DEFAULT SETTINGS (only for Quickscan M2 Type:130)
USA keyboard, caps lock off, caps lock auto-recognition enabled; num lock unchanged, inter-character and inter-code delay disabled.
DATA FORMAT: code identifier disabled, code length not transmitted, no header, terminator = ENTER, character replacement disabled, address stamping disabled, address delimiter disabled.
IBM DEFAULT SETTINGS (only for Quickscan M2 Type:110)
DATA FORMAT: IBM Standard, code identifier disabled, no header, no terminator
PEN DEFAULT SETTINGS
Interpret operating mode, minimum output pulse 600 μs, conversion to Code 39, overflow medium, output level normal, idle level normal, inter-block delay disabled.
Technical Features
QuickScan® Mobile Reader and Cradle
Electrical Features - READER Battery Type 1 Lithium battery 700 mAh Time of recharge Lithium max 6 hours with USB cable Operating autonomy typical 20000 reads Indicators LED, Beeper Max scan rate 235 scans/sec Electrical Features - CRADLE
Supply voltage
5 VDC ± 5%
Power consumption max. 4 W (charging) LED Indicators Battery charging red
Charge completed green
Power / Data yellow
Optical Features Sensor CCD solid state (2088 pixels) Illuminator LED array Wavelength 630 ~ 670 nm Max. LED Output Power 0.33 mW LED safety class Class 1 EN 60825-1 Reading field see reading table Max. resolution 0.10 mm, 4 mils PCS minimum 20% (Datalogic Test Chart)
Technical Features
Quick Reference Guide 25
QuickScan® Mobile Radio Features
Environmental Features – READER Working Temperature
0° to + 40 ° C (32° to 104 °F) Storage Temperature (without battery)
-20° to 70 °C (-4° to 158 °F)
Humidity 90% non condensing Drop resistance
IEC 68-2-32 Test ED 1.5 m (4 ft 9 in)
Protection class IP30
Environmental Features - CRADLE
Working temperature 0° to 40 °C (32° to 104 °F) Storage temperature -20° to 70 °C (-4° to 158 °F) Humidity 90 % non condensing Protection class
IP30
Mechanical Features – READER Weight (without batteries)
about 189 g (6.66 oz)
Dimensions 171 x 90 x 68 mm (6.72 x 3.54 x 2.80 in) Material Cycoloy C 2800 with desmopan 3855
Mechanical Features – CRADLE Weight
181 gr (6.38 oz)
Dimensions 80 x 130 x 90 mm (3.15 x 5.11 x 3.54 in) Material Cycoloy C 2800 with desmopan 3855
Radio Features European Models USA Models Radio Frequency 433.92 MHz 910 MHz Bit rate 19200 baud 36800 baud Effective Radiated Power <10 mW <1 mW Range (in open air) 12 m 12 m RF Modulation FSK
Compliance
26 QuickScan™ Mobile
Compliance
This device must be opened by qualified personnel only. The batteries must be removed before opening the device.
Power Supply
This device is intended to be supplied by a UL Listed/CSA Certified Power Unit marked "Class 2" or LPS power source rated 5 V, minimum 0.8 A and having a
cable length <3 m.
FCC Compliance
Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
Atencíon
Características de la
fuente de alimentación
eléctrica.
Entrada:
100 - 240 VCA min 350 mA 50-60 HZ.
Salida:
máx 5,2VDC, máx 2500mA (-)Negativo al centro
Utilice en su red solo fuentes certificadas en Argentina.
El uso de fuentes de alimentación no compatibles puede resultar en riesgo de incendio o de choque eléctrico para el usuario.
Compliance
Quick Reference Guide 27
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
LED Class
QuickScanTM Mobile Product Label
Class 1 LED product.
Radio Compliance
Contact the competent authority responsible for the management of radio frequency devices of your country to verify the eventual necessity of a user license. Refer to the web site http://europa.eu.int/comm/enterprise/rtte/ spectr.htm for further information.
Brazilian Certification Statement
EN60825-1:(2001)
(01)07898916345048
2697-08-4727
Agência Nacional de Telecomunicações
“Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário.”
Compliance
28 QuickScan™ Mobile
China RoHS Table of Restricted Elements (Scanner)
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr(VI))
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
᦭Ქ᦭ኂ‛ᚗర⚛
PART
ㇱઙฬ⒓
౐ચ ᄽ侶૖ ᄽԲ૖ㅘ
Printed Circuit Board Assembly
⬉䏃ᵓ㒘ӊ
X O O O O O
Assy, Optics Block
ܝᄺ㒘ӊ
X O O O O O
Assy, Module
ܝᄺ㒘ӊ
X O O O O O
Oઍ⴫ᱝㇱઙ⊛ᚲ᦭ဋ凝ޗறխࢬܶ具Ẋڶڶ୭凝݁܅Պխ䦀Գا٥ࡉ㧺ஒ䣈䢓ຝ咒ؒ⊛
ޝ䶣՗ஒ䣈঴խڶڶ୭凝ૻၦ૞ޣρ(SJ/T 11363-2006) 億ࡳૻၦޕ
X:ઍ⴫ᱝㇱઙᚲ↪⊛ဋ凝ޗறխ, ⥋ዋ᦭৻᧚ᢱ౔ᚲ฽⊛
᦭Ქ᦭ኂ‛凝೏Պխ䦀Գا٥ࡉ㧺ஒ䣈䢓ຝ咒ؒ
ޝ䶣՗ஒ䣈঴խڶڶ୭凝ૻၦ૞ޣρ(SJ/T 11363-2006) 億ࡳૻ
Compliance
Quick Reference Guide 29
China RoHS Table of Restricted Elements (Base)
ㇱઙฬ⒓
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr(VI))
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
᦭Ქ᦭ኂ‛ᚗర⚛
PART
౐ચ ᄽ侶૖ ᄽԲ૖ㅘ
Printed Circuit Board Assembly
⬉䏃ᵓ㒘ӊ
X O O O O O
Assy, Module
ܝᄺ㒘ӊ
X O O O O O
O
ઍ⴫ᱝẊㇱઙ⊛ᚲ᦭ဋ凝ޗறխࢬܶ具Ẋڶڶ୭凝݁܅Պխ䦀Գا٥ࡉ㧺ஒ䣈䢓ຝᚲ咒ؒ⊛
ޝ䶣՗ஒ䣈঴խڶڶ୭凝ૻၦ૞ޣρ(SJ/T 11363-2006) 億ࡳૻၦޕ
X:
ઍ⴫ᱝẊㇱઙᚲ↪⊛ဋ凝ޗறխ, ⥋ዋ᦭৻㮕᧚ᢱ౔ᚲ฽⊛᦭Ქ᦭ኂ‛凝೏Պխ䦀Գا٥ࡉ㧺ஒ䣈䢓ຝᚲ咒ؒ⊛
ޝ䶣՗ஒ䣈঴խڶڶ୭凝ૻၦ૞ޣρ(SJ/T 11363-2006) 億ࡳૻ
Compliance
30 QuickScan™ Mobile
WEEE Statement
English
For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.datalogic.com.
Italian
Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.datalogic.com.
French
Pour toute information relative à l’élimination des déchets électroniques (WEEE), veuillez consulter le site internet www.datalogic.com.
German
Informationen zur Entsorgung von Elektro- und Elektronik- Altgeräten (WEEE) erhalten Sie auf der Webseite www.datalogic.com.
Spanish
Si desea información acerca de los procedimientos para el desecho de los residuos del equipo eléctrico y electrónico (WEEE), visite la página Web www.datalogic.com.
Portuguese
Para informações sobre a disposição de Sucatagem de Equipamentos Elétricos e Eletrônicos (WEEE -Waste Electrical and Electronic Equipment), consultar o site web www.datalogic.com.
Chinese
有关处理废弃电气电子设备 (WEEE) 的信息, 请参考
Datalogic
公司的网站
www.datalogic.com
/。
Japanese
廃電気電子機器 (WEEE) の処理についての関連事項は Datalogic の サイト www.datalogic.com をご参照下さい。
Waste Electrical and Electronic Equipment (WEEE) Statement
Datalogic ADC Limited Factory Warranty
Quick Reference Guide 31
Datalogic ADC Limited Factory Warranty
Warranty Coverage
Datalogic warranties this product against defects in workmanship and materials, for a period of 3 years (36 months) from the date of shipment, provided that the product is operated un­der normal and proper conditions. Datalogic (“Datalogic”) hardware products are warranted against defects in material and workmanship under normal and proper use. The liability of Datalogic under this warranty is limited to furnishing the labor and parts necessary to rem­edy any defect covered by this warranty and restore the product to its normal operating con­dition. Repair or replacement of product during the warranty does not extend the original warranty term. Products are sold on the basis of specifications applicable at the time of manufacture and Datalogic has no obligation to modify or update products once sold.
If Datalogic determines that a product has defects in material or workmanship, Datalogic shall, at its sole option repair or replace the product without additional charge for parts and labor, or credit or refund the defective products duly returned to Datalogic. To perform re­pairs, Datalogic may use new or reconditioned parts, components, subassemblies or prod­ucts that have been tested as meeting applicable specifications for equivalent new material and products. Customer will allow Datalogic to scrap all parts removed from the repaired product. The warranty period shall extend from the date of shipment from Datalogic for the duration published by Datalogic for the product at the time of purchase (Warranty period). Datalogic warrants repaired hardware devices against defects in workmanship and materi­als on the repaired assembly for a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original warranty period, which­ever is longer. Datalogic does not guarantee, and it is not responsible for, the maintenance of, damage to, or loss of configurations, data, and applications on the repaired units and at its sole discretion can return the units in the “factory default” configuration or with any soft­ware or firmware update available at the time of the repair (other than the firmware or soft­ware installed during the manufacture of the product). Customer accepts responsibility to maintain a back up copy of its software and data.
Warranty Claims Process
In order to obtain service under the Factory Warranty, Customer must notify Datalogic of the claimed defect before the expiration of the applicable Warranty period and obtain from Dat­alogic a return authorization number (RMA) for return of the product to a designated Data­logic service center. If Datalogic determines Customer’s claim is valid, Datalogic will repair or replace product without additional charge for parts and labor. Customer shall be responsible for packaging and shipping the product to the designated Datalogic service center, with ship­ping charges prepaid. Datalogic shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Datalogic service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations. Failure to follow the applicable RMA policy, may result in a processing fee. Customer shall be responsible for return shipment ex­penses for products which Datalogic, at its sole discretion, determines are not defective or eligible for warranty repair.
Warranty Exclusions
The Datalogic Factory Warranty shall not apply to:
(i) any product which has been damaged, modified, altered, repaired or upgraded by
other than Datalogic service personnel or its authorized representatives;
(ii) any claimed defect, failure or damage which Datalogic determines was caused by
faulty operations, improper use, abuse, misuse, wear and tear, negligence, improper storage or use of parts or accessories not approved or supplied by Datalogic;
(iii) any claimed defect or damage caused by the use of product with any other instru-
ment, equipment or apparatus;
(iv) any claimed defect or damage caused by the failure to provide proper maintenance,
including but not limited to cleaning the upper window in accordance with product manual;
(v) any defect or damage caused by natural or man-made disaster such as but not lim-
ited to fire, water damage, floods, other natural disasters, vandalism or abusive events that would cause internal and external component damage or destruction of the whole unit, consumable items;
Ergonomic Recommendations
32 QuickScan™ Mobile
(vi) any damage or malfunctioning caused by non-restoring action as for example firm-
ware or software upgrades, software or hardware reconfigurations etc.;
(vii) the replacement of upper window/cartridge due to scratching, stains or other deg-
radation and/or
(viii) any consumable or equivalent (e.g., cables, power supply, batteries, keypads, touch
screen, triggers etc.).
No Assignment
Customer may not assign or otherwise transfer its rights or obligations under this warranty except to a purchaser or transferee of product. No attempted assignment or transfer in vio­lation of this provision shall be valid or binding upon Datalogic.
DATALOGIC'S LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IM­PLIED, ORAL OR WRITTEN, STATUTORY OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NONINFRINGEMENT. DATALOGIC SHALL NOT BE LIABLE FOR ANY DAMAGES SUSTAINED BY CUSTOMER ARISING FROM DELAYS IN THE REPLACEMENT OR REPAIR OF PRODUCTS UN­DER THE ABOVE. THE REMEDY SET FORTH IN THIS WARRANTY STATEMENT IS THE CUSTOM­ER’S SOLE AND EXCLUSIVE REMEDY FOR WARRANTY CLAIMS. UNDER NO CIRCUMSTANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR ANY LOST PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL IN-DIRECT, SPECIAL OR CONTINGENT DAMAGES RE­GARDLESS OF WHETHER DATALOGIC HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Risk of Loss
Customer shall bear risk of loss or damage for product in transit to Datalogic. Datalogic shall assume risk of loss or damage for product in Datalogic’s possession. In the absence of spe­cific written instructions for the return of product to Customer, Datalogic will select the car­rier, but Datalogic shall not thereby assume any liability in connection with the return shipment.
Ergonomic Recommendations
Reduce or eliminate repetitive motion
Maintain a natural position
Reduce or eliminate excessive force
Keep objects that are used frequently within easy reach
Perform tasks at correct heights
Reduce or eliminate vibration
Reduce or eliminate direct pressure
Provide adjustable workstations
Provide adequate clearance
Provide a suitable working environment
Improve work procedures
CAUTION
In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local Health & Safety Manager to ensure that you are adhering to your company’s safety programs to prevent employee injury.
Services and Support
Quick Reference Guide 33
Services and Support
Datalogic provides several services as well as technical support through its website. Log on to
www.datalogic.com
and click on the links indicated for fur-
ther information.
Products
Search through the links to arrive at your product page where you can down­load specific
Manuals
and
Software & Utilities
, including:
Datalogic Aladdin™
, a multi-platform utility program that allows device configuration using a PC. It provides RS-232 and USB-COM interface configuration, printing of configuration bar codes, and firmware upgrades.
Service & Support
Technical Support
- Product documentation and programming guides
and Technical Support Department in the world
Service Programs
- Warranty Extensions and Maintenance Agree-
ments
Repair Services
- Flat Rate Repairs and Return Material Authoriza-
tion (RMA) Repairs
Downloads
– Manuals & Documentation, Data Sheets, Product Cata-
logues, etc.
Contact Us
Information Request Form and Sales & Service Network
Services and Support
34 QuickScan™ Mobile
NOTES
DECLARATION OF CONFORMITY
La presente dichiarazione di conformità è rilasciata sotto la responsabilità esclusiva di Datalogic ADC Srl per: This Declaration of Conformity is issued under the sole responsibility of Datalogic ADC Srl for: Cette déclaration de conformité est établie sous la seule responsabilité de Datalogic Srl pour: Diese Konformitätserklärung wird unter der alleinigen Verantwortung des Datalogic ADC Srl erteilt für: Esta declaración de conformidad se expide bajo la exclusiva responsabilidad de Datalogic ADC Srl para:
QUICKSCAN M21XX Kit 433Mhz ; Cordless System
sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: den nachstehenden angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:
1999/5/EC - R&TTE Directive
2011/65/EU - RoHS Directive
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:
Datalogic ADC Srl, Via S. Vitalino, 13
Lippo di Calderara di Reno (BO) 40012 Italy
EC-048
Rev.: 3
Pag.: 1 di 1
e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos
ETSI EN 301 489-3 V1.4.1, A
UGUST
2002:
E
LECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); E
LECTROMAGNETIC COMPATIBILITY
(EMC) S
TANDARD FOR RADIO
E
QUIPMENT AND SERVICES
; P
ART
3: S
PECIFIC CONDITIONS FOR SHORT
-
RANGE DEVICES
(SRD) O
PERATING ON FREQUENCIES BETWEEN 9KHZ
AND
40
GHZ
EN 301 489-1 V1.8.1, A
PRIL
2002:
E
LECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); E
LECTROMAGNETIC COMPATIBILITY
(EMC) S
TANDARD FOR RADIO
E
QUIPMENT AND SERVICES
; P
ART
1: C
OMMON TECHNICAL
R
EQUIREMENTS
ETSI EN 300 220-2 V2.1.2, J
UNE
2007:
E
LECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); S
HORT RANGE DEVICES
(SRD); R
ADIO EQUIPMENT TO BE USED
IN THE
25MHZ TO 1000MHZ F
REQUENCY RANGE WITH POWER LEVELS
R
ANGING UP TO
500MW;
P
ART
2: H
ARMONIZED EN COVERING ESSENTIAL REQUIREMENTS UNDER
A
RTICLE
3.2 OF
THE
R&TTE D
IRECTIVE
EN 60950-1, A
PRIL
2006 + A11:2009+
A1:2010 + A12:2011:
IN
FORMATION TECHNOLOGY EQUIPMENT
- S
AFETY
-
P
ART
1 : G
ENERAL REQUIREMENTS
EN 50581, S
EPTEMBER
2012 :
T
ECHNICAL DOCUMENTATION FOR THE ASSESSMENT OF ELECTRICAL AND
E
LECTRONIC PRODUCTS WITH RESPECT TO THE RESTRICTION OF
H
AZARDOUS SUBSTANCES
Lippo di Calderara, March 29th , 2013
R
UGGERO CACIOPPO
Q
UALITY
& R
ELIABILITY MANAGER
- E
UROPE
13
©2008-2014 Datalogic, Inc. • All rights reserved. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U.
Datalogic ADC, Inc.
959 Terry Street | Eugene |OR 97402 | USA Telephone: (1) 541-683-5700
|
Fax: (1) 541-345-7140
www.datalogic.com
820037114 (Rev G)
May 2014
Loading...