Datalogic LYNX BT 432, LYNX BT 432E Quick Reference Manual

Quick Reference Guide
Lynx™ BT Readers
09/07
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”). Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation. Should future revisions of this manual be published, you can acquire printed versions by contacting your Datalogic representative. Electronic versions may either be downloadable from the Datalogic website (www.scanning.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Contact Datalogic" page.
DISCLAIMER
Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice. Datalogic is a registered trademark of Datalogic S.p.A. in many countries and the Datalogic logo is a trademark of Datalogic S.p.A. all licensed to Datalogic Scanning, Inc. All other trademarks and trade names referred to herein are property of their respective owners.
CONTENTS
Updates and Language Availability.....................................................................iv
Using Lynx™ BT Series Readers........................................................................ 1
Charging the Batteries ........................................................................................ 2
Lynx™ BT Operation........................................................................................... 4
Lynx™ BT Configuration..................................................................................... 8
Operating Test .................................................................................................. 10
Lynx™ BT Default Configuration....................................................................... 11
Technical Features............................................................................................ 13
Troubleshooting ................................................................................................ 16
Patents.............................................................................................................. 17
Services and Support........................................................................................ 17
Warranty............................................................................................................ 17
Compliance....................................................................................................... 18
Hex Numeric Table ........................................................................................... 23
iii
UPDATES AND LANGUAGE AVAILABILITY
UK/US
The latest drivers and documentation updates for this product are available on
Internet.
Log on to: www.scanning.datalogic.com
I
Su Internet sono disponibili le versioni aggiornate di driver e documentazione di
questo prodotto. Questo manuale è disponibile anche nella versione italiana.
Collegarsi a: www.scanning.datalogic.com
F
Les versions mises à jour de drivers et documentation de ce produit sont
disponibles sur Internet. Ce manuel est aussi disponible en version française.
Cliquez sur: www.scanning.datalogic.com
D
Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation
für dieses Produkt. Die deutschsprachige Version dieses Handbuches ist auch
verfügbar.
Adresse : www.scanning.datalogic.com
E
En Internet están disponibles las versiones actualizadas de los drivers y documentación de este producto. También está disponible la versión en
español de este manual.
Dirección Internet: www.scanning.datalogic.com
iv
USING LYNX™ BT SERIES READERS
LYNX™ BT
The Lynx™ BT (Lynx™ Bluetooth
®
) series reader is a wireless scanner communicating in the 2.4 GHz ISM band and using the Serial Port Profile (SPP).
The Lynx™ BT series reader, paired with an OM-1000 BT cradle, builds a Cordless Reading System for the collection, decoding and transmission of decoded data. OM-1000 BT can be connected to a Host PC through a USB, RS232 or Wedge emulation cable. For details refer to the OM-1000 BT Quick Reference Guide. OM-1000 BT also serves as a battery charger for Lynx™ BT.
Together with a Bluetooth Cordless Reading System for the collection, decoding and transmission of decoded data. The Bluetooth printer, etc with a built-in Bluetooth (i.e. a Bluetooth
®
dongle).
®
compatible remote device, Lynx™ BT also builds a
®
compatible remote device can be a PC, PDA,
®
device or with external Bluetooth® adapter
Using this Quick Reference Manual, you can initialize and start using your Lynx™ BT reader with its default values for communicating with a Bluetooth
®
device. To change the default values or for details about general configuration commands, refer to the Lynx™ BT Reference Manual on the configuration CD-ROM.
Thanks to its aiming system, Lynx™ BT visually indicates the reading area and since Lynx™ BT is a powerful omni-directional reader, the orientation of the symbol is not important.
AIMING SYSTEM
The Lynx™ BT reader uses an intelligent aiming system similar to those on cameras. By partially pulling the trigger, the aiming system indicates a field of view to be positioned over the code:
When you pull the trigger completely a red beam illuminates the code. If the aiming system is centered and the entire code is within the aiming system, you will get a good read. The field of view changes size as you move the reader closer or farther away from the code.
Aiming System
1
DATALOGIC
Linear barcode 2D Matrix symbol
Relative Size and Location of Aiming System Pattern
The field of view indicated by the aiming system will be smaller when the Lynx™ BT is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. Successful reading is signaled by an audible tone plus a good-read green led.
If reading codes positioned on reflective surfaces, it may be necessary to tilt the reader with respect to the code and/or set the Camera Control parameters. For configuring the Camera
NOTE
Control parameters refer to the Lynx™ BT Reference Manual available on the CD-ROM.
CHARGING THE BATTERIES
By placing the reader into the C-1000 battery charger or the OM-1000 BT cradle it is possible to charge the Lynx™ BT batteries. Make sure the charging LED goes on.
The LEDs positioned on the battery charger signal the charge status, as described in the following table:
LED STATUS
Charging Red On = the battery charge is in progress. Batt Full Green On = the battery is completely charged.
2
LYNX™ BT
Charge completed
The batteries must be charged at a temperature ranging from 0° to 45 °C (+32° to +113 °F).
NOTE
For further details about LED functioning refer to the C-1000 and OM-1000 BT Quick Reference Guide.
Power on Charging
CHANGING THE BATTERIES
To change the batteries of your reader, unscrew the battery cover screw, replace the old battery pack with a new one of the same type, then insert the cover onto the handle and screw it back into place. (See the following figures).
To turn on the reader, press the trigger.
Battery Cover Screw
Do not incinerate, disassemble, short terminals or expose to high temperature. Risk of fire, explosion. Use specified charger only. Risk of explosion if the battery is
WARNING
replaced by an incorrect type. Dispose of the batteries as required by the relevant laws in force.
3
DATALOGIC
POWERING THE C-1000/OM-1000 BT
Connections should always be made with power off!
CAUTION
Apply power to C-1000/OM-1000 BT by connecting a power supply unit to the connector on the rear panel of the battery charger/cradle.
C-1000/OM-1000 BT is ready to charge Lynx™ BT Series readers with Li-Ion batteries.
Power Supply
C-1000 Power Supply Connector
LYNX™ BT OPERATION
RADIO CONNECTION
In the Bluetooth Master.
The green LED and/or the beeper always indicate the reader radio connection status (see the table on page 5).
®
radio connection, the Lynx™ BT can operate as Slave or as
4
LYNX™ BT
STATUS INDICATORS
Lynx™ BT Series Reader LED Functioning
LED Behavior
Red at Power On, blinks briefly, then a beep occurs. Then, it turns off;
lights when a wrong read occurs; lights briefly when the aiming system is enabled;
Green lights when a code has been read and decoded;
blinks during binding with OM-1000 BT (see OM-1000 BT Quick Reference Guide for details);
single blink every 2 seconds when BT connection is active; double blink every 2 seconds when BT connection is not active.
Lynx™ BT Series Reader Beeper Functioning
Beeper Behavior Condition
4 ascending tones during radio connection initialization. 4 descending tones upon radio disconnection. 2 beeps upon good read of a code, when paired to OM-1000
BT cradle.
1 beep upon good read of a code, when communicating with
a BT device.