DEFAULT VALUES
USB-KBD DEFAULT SETTINGS
USA keyboard, FIFO enabled, inter-character and i nter-code delays disab led,
control character emulation = ctrl+shift+key.
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = ENTER, character replacement disabled.
RS232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx
timeout 5 sec., ack/nack disabled, FIFO enabled, serial trigger lock disabled.
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = CR-LF, character replacement disabled.
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, caps lock auto-recognition enabled, num lock
unchanged, inter-character and inter-code delays disabled, control character
emulation = ctrl+shift+key.
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = ENTER, character replacement disable.
PEN DEFAULT SETTINGS
interpret mode, conversion to code 39 disabled, output level normal, idle level
normal, minimum output pulse 600 μs, overflow medium, inter-block delay disabled.
CODE SELECTION
Enabled codes
• EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
• Interleaved 2/5
check digit control and transmission, variable length code; 4-99 characters
• Standard Code 39
no check digit control, variable length code; 1-99 characters
• Code 128
variable length code; 1-99 characters
Disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI,
Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49, RSS Codes
TECHNICAL FEATURES
Heron™ D130
Electrical Features
Power Supply
RS232 interface
5 Vdc ± 5%
Consumption:
Maximum
Operating
Sleep mode/USB Suspend
180 mA @ 5 Vdc
155 mA @ 5 Vdc
<500 μA @ 5 Vdc
Max. Scan Rate 256 scans/sec
Reading Indicators LED, Good Read Spot, Beeper
Optical Features
Sensor CCD solid state (2048 pixels)
Illuminator LED array
Wavelength 630 ~ 670 nm
Max. LED Output Power 0.31 mW
LED Safety Class Class 1 EN 60825-1
Reading Field 2 ~ 27 cm (20 mils)
Max. Resolution 0.10 mm (4 mils)
PCS (Datalogic Test Chart) min. 15%
Environmental Features
Working Temperature
0 °C to + 55 °C (+32° to +131 °F)
Storage Temperature
-20 °C to + 70 °C (-4° to +158 °F)
Humidity 90% non condensing
Drop Resistance
IEC 68-2-32 Test ED
1.8 m (5.9 ft)
ESD Protection 16 KV
Protection Class IP30
Mechanical Features
Weight (without cable) about 160 g (5.6 oz)
Cable Length 2 m (6 ft 6 in)
RESTORE DEFAULT
RESTORE DEFAULT
Ì$+$*oÎ
To change the defaults refer to the HHD II Software Configuration Manual, part
number 90ACC1877, or to the Configuration program, both downloadable from the
website.
INTERFACE SELECTION
Select one of the interface codes according to your application.
USB INTERFACE SELECTION
USB-KBD
Ì$+UA03$-:Î
USB-KBD - ALT-mode
Ì$+UA04$-@Î
USB-COM *
Ì$+UA02$-4Î
USB-IBM-Hand Held
Ì$+UA01$-.Î
* When configuring USB-COM, the relevant files and drivers must be installed
from the USB Device Installation software, which can be downloaded from the
web site http://www.datalogic.com.
PEN EMULATION INTERFACE SELECTION
PEN
Ì$+CP6$-BÎ
RS232 INTERFACE SELECTION
RS232 Standard
Ì$+CP0$-$Î
Nixdorf Mode A
Ì$+CM2EC0$->Î
None
Ì$+EA10$-dÎ
OPERATING TEST
Read the TEST code below.
Code 128
test
USING HERON™ SERIES READERS
Heron™ guns automatically scan barcodes at a distance. Simply aim and pull the
trigger. Code scanning is performed along the center of the light bar emitted from
the reading window. This bar must cover the entire code.
Successful scanning is obtained by tilting the scanner with respect to the barcode
to avoid direct reflections, which impair the reading performance, see the figure
above.
Successful reading is signaled by an audible tone plus a good-read green spot.
By correctly inserting the reader into the stand, it is immediately ready to
automatically read any code present in its reading area without pressing the
trigger. Furthermore, a green aiming light is continuously emitted to facilitate the
positioning of the barcode to be read, see the figure above.
To guarantee single code reading, same code consecutive reading requires the
code to be removed from the reading area (no decoding) before the reader will
accept the same code.
STAND INSTALLATION
The stand can be mounted by using self-tapping screws, double sided adhesive
strips or rubber feet:
A) mount the stand directly to the surface using the
self-tapping screws;
B) carefully clean the bottom surface of the stand and the table surface.
Remove the protective plastic from one side of the adhesive strips and stic