Datalogic Gryphon D130, Gryphon D230 User guide

Datalogic Scanning, Inc.
A
r
r
r
A
t
r
A
959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140
Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prio notice. Datalogic is a registered trademark of Datalogic S.p.A. in many countries and the Datalogic logo is a trademark of Datalogic S.p.A. all licensed to Datalogic Scanning, Inc. All other trademarks and trade names referred to herein are property of their respective owners.

SERVICES AND SUPPORT

Datalogic provides several services as well as technical support through its website. Log on to
www.scanning.datalogic.com and click on the

DISCLAIMER

links indicated for further information including:
PRODUCTS
Search through the links to arrive at your product page where you can download specific
Manuals and Software & Utilities including:
- Datalogic Aladdin™ a multi-platform utility program, which allows device configuration using
a PC. It provides RS232/USB-COM interface configuration as well as configuration barcode printing.

CONNECTIONS

DISCONNECTING THE CABLE

Gryphon™
USB
Dx30 Readers
QUICK REFERENCE GUIDE

WEDGE

RS232
SERVICES & SUPPORT
Datalogic Services - Warranty Extensions and Maintenance Agreements
-
-
Authorised Repair Centres
CONTACT US
E-mail form and listing of Datalogic Subsidiaries

WARRANTY

Datalogic warranties this product against defects in workmanship and materials, for a period of 5 years from the date of shipment, provided that the product is operated under normal and proper conditions.
Datalogic has the faculty to repair or replace the product; these provisions do not prolong the original warranty term.
The warranty does not apply to any product that has been subject to misuse, accidental damage, unauthorized repair or tampering.
dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el
Gryphon D1XX Gryphon D2XX
e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos
sono conformi alle Direttive del Consigl io Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne c i-dessous: den nachstehenden angeführten Direktiven des Europ äischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:
89/336/EEC EMC Directive
Basate sulle legislazioni degl i Stati membri in relazione alla compatibilità elettr omagnetica ed alla sicurezza d ei prodotti. On the approximation of the laws of Mem ber States relating to electromagnetic compatibility and product safety. Basée sur la législation des Etats mem bres relative à la compatibilité électro magnétique et à la sécurité des produits. Über die Annäherung der Gesetze der Mitgliedss taaten in bezug auf elektromagnetische Ver träglichkeit und Produktsicherheit entsprechen. Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibi lidad electromagnética y las Medidas de seguridad relativas al producto.
Questa dichiarazione è basata sulla conformità dei prodotti alle norm e seguenti: This declaration is bas ed upon compliance of the products to the follow ing standards: Cette déclaration repose sur la conform ité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspr icht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:
EN 55022 (C
LASS A ITE), August 1994:
A
MENDMENT A1 (CLASS A ITE), October 2000:
EN 61000-6-2, October 2001:
March 1st, 2007
92/31/EEC, 93/68/EEC
e
and
et
und
y
Datalogic Scanning, Inc.
959 Terry Street
Eugene, OR 97402
emendamenti successivi further amendments ses successifs amendements späteren Abänderungen succesivas enmiendas
L
IMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT
E
LECTROMAGNETIC COMPATIBILITY (EMC).
P
ART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS
.
07
820001613eng (Rev. D) 9/07

UPDATES AND LANGUAGE AVAILABILITY

UK/US
The latest drivers and documentation updates for this product are available on
Internet.
Log on to: www.scanning.datalogic.com
I
Su Internet sono disponibili le versioni aggiornate di driver e documentazione di
questo prodotto. Questo manuale è disponibile anche nella versione italiana.
Collegarsi a: www.scanning.datalogic.com
F
Les versions mises à jour de drivers et documentation de ce produit sont
disponibles sur Internet. Ce manuel est aussi disponible en version française.
Cliquez sur : www.scanning.datalogic.com
D
Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation
von diesem Produkt. Die deutschsprachige Version dieses Handbuches ist auch
verfügbar.
Adresse : www.scanning.datalogic.com
E
En Internet están disponibles las versiones actualizadas de los drivers y
documentación de este producto. También está disponible la versión en español
de este manual.
Dirección Internet : www.scanning.datalogic.com
PEN

COMPLIANCE

LED CLASS

Class 1 LED product.
This product conforms to EN60825-1:2001.

FCC COMPLIANCE

Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference a his own expense.

POWER SUPPLY

This device is intended to be connected to a UL Listed/CSA Certified compute which supplies power directly to the reader or else be supplied by a UL Listed/CS Certified Power Unit marked “Class 2” or LPS power source rated 5 V, minimum 270 mA, which supplies power directly to the reader via the power connector of the cable.

WEEE COMPLIANCE

PATENTS

This product is licensed under the following U.S. patent: 6,158,661 This product is covered by one or more of the following patents: U.S. patents 5,992,740; 6,305,606 B1; 6,517,003 B2; 6,631,846 B2; 6,712,271
B2; 6,808,114 B1; 6,817,525 B2; and 6,834,806 B2
European patents 851,378 B1; 895,175 B1; 962,880 B1; 997,760 B1; 1,128,315 B1; and 1,164,536 B1
Additional patents pending.

DEFAULT VALUES

USB-KBD DEFAULT SETTINGS
USA keyboard, FIFO enabled, inter-character and inter-code delays disabled, USB keyboard speed normal.
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = ENTER, character replacement disabled.
RS232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx timeout 5 sec., ack/nack disabled, FIFO enabled, serial trigger lock disabled.
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = CR-LF, character replacement disabled.
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, caps lock auto-recognition enabled, num lock unchanged, inter-character and inter-code delays disabled.
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = ENTER, character replacement disable.
PEN DEFAULT SETTINGS
interpret mode, conversion to code 39 disabled, output level normal, idle level normal, minimum output pulse 600 μs, overflow medium, inter-block delay disabled.
CODE SELECTION
Enabled codes
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
Interleaved 2/5
check digit control and transmission, variable length code; 4-99 characters
Standard Code 39
no check digit control, variable length code; 1-99 characters
Code 128
variable length code; 1-99 characters
Disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI, Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49, RSS Codes

RESTORE DEFAULT

RESTORE DEFAULT
Ì$+$*oÎ
To change the defaults refer to the “Gryphon™ Dx30/Mx30 Reference Manual”, part number 90ACC1930, or to the Datalogic Aladdin™ Configuration program, both downloadable from the website.

INTERFACE SELECTION

Select one of the interface codes according to your application.
Ì$+UA03$-:Î
Ì$+UA02$-4Î
* When configuring USB-COM, the relevant files and drivers must be installed
from the USB Device Installation software, which can be downloaded from the web site http://www.scanning.datalogic.com.
Ì$+CP6$-BÎ

USB INTERFACE SELECTION

USB-KBD
USB-KBD - ALT-mode
Ì$+UA04$-@Î
USB-COM *
USB-IBM-Hand Held
Ì$+UA01$-.Î

PEN EMULATION INTERFACE SELECTION

PEN

KEYBOARD NATIONALITY

USB-KBD and Wedge users should select one of the following wedge keyboard nationality codes according to your keyboard.
Ì$+FJ7$-8Î
Ì$+FJ4$-)Î
Ì$+FJ2$-ÊÎ
Ì$+FJ8$-=Î
Ì$+FJ0$-|Î
Belge
Deutsch
Ì$+FJ3$-$Î
English
Español
Ì$+FJ6$-3Î
Français
Italiano
Ì$+FJ1$-ÅÎ
Japanese
Svenskt
Ì$+FJ5$-.Î
USA (Default)
USING GRYPHON DX30 READERS
Gryphon guns automatically scan barcodes at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code. Successful scanning is obtained by tilting the scanner with respect to the barcode to avoid direct reflections, which impair the reading performance, see the figure above. Successful reading is signaled by an audible tone plus a good-read green spot.

TECHNICAL FEATURES

Electrical Features
Power Supply Consumption: Gryphon D130 Gryphon D230
Maximum Operating Sleep mode/USB Suspend
Max. Scan Rate 270 scans/sec Reading Indicators LED, Good Read Spot, Beeper
Optical Features
Sensor CCD solid state (3648 pixels) Illuminator LED array Wavelength 630 ~ 670 nm Max. LED Output Power 0.33 mW LED Safety Class Class 1 EN 60825-1
Gryphon D130-Std 2 ~ 37 cm (20 mils)
Reading Field
Max. Resolution Gryphon Dx30-Std Gryphon D130-LR
0.076 mm (3 mils) 0.11 mm (4.3 mils) PCS (Datalogic Test Chart) min. 15%
Environmental Features
Working Temperature Storage Temperature Humidity 90% non condensing
Drop Resistance
Protection Class IP30
Mechanical Features
Weight (without cable) about 210 g (7.4 oz) Cable Length 2 m (6 ft 6 in)
Gryphon D130-LR 1 ~ 55 cm (20 mils)
Gryphon D230
Gryphon Dx30
270 mA@ 5 Vdc 165 mA@ 5 Vdc <500 µA@ 5 Vdc
2 ~ 25 cm (20 mils)
3 ~ 14 c m (15 mils) for PDF417 code
0 °C to + 55 °C / 32° to +131 °F
-20 °C to + 70 °C / -4° to +158 °F
IEC 68-2-32 Test ED
5 Vdc ± 5%
270 mA@ 5 Vdc 210 mA@ 5 Vdc
4 mA@ 5 Vdc
1.8 m (5 ft 11 in)
Ì$+CP0$-$Î
Ì$+CM1$-ÈÎ
Wedge IBM AT or PS/2 PCs
Ì$+CP500$-aÎ
PC Notebook - ALT mode
Ì$+CP508$-2Î
Many other interfaces are supported and can be selected from the “Gryphon™ Dx30/Mx30 Reference Manual” available online at www.scanning.datalogic.com. Other supported interfaces:
USB: USB-IBM-Table Top; USB-KBD-APPLE WEDGE: IBM XT; IBM SURE1; IBM Terminal 3153; IBM Terminals 31xx, 32xx,
34xx, 37xx; Wyse Terminals ANSI – PC –ASCII – VT220 style Keyboards; Digital Terminal VT2xx/VT3xx/VT4xx; APPLE ADB Bus

RS232 INTERFACE SELECTION

RS232 Standard
Nixdorf Mode A
Ì$+CM2EC0$->Î
Fujitsu
ICL Mode
Ì$+CM0$-ÃÎ

WEDGE INTERFACE SELECTION

PC Notebook
Ì$+CP505$-ÈÎ
IBM AT - ALT mode
Ì$+CP507$-+Î

DATA FORMAT TERMINATORS

For your convenience, some common Terminators are given below. For other Header/Terminator selections, Data Format and Advanced Data Format parameters, see the “Gryphon™ Dx30/Mx30 Reference Manual”.
CR-LF
Ì$+EA120D0A$-ÃÎ
Enter
Ì$+EA1183$-0Î
Tab
Ì$+EA1184$-8Î
None
Ì$+EA10$-dÎ

OPERATING TEST

Read the TEST codes below.
1 234567 000992
0123456784
EAN-8
1234 5670
EAN-13
Code 39 (Normal)
17162
Code 128
test
Interleaved 2 of 5