Datalogic Mobile S.r.l.
Via S. Vitalino 13
40012 - Lippo di Calderara di Reno
Bologna - Italy
Formula™ - User's Manual
Ed.: 12/2008
ALL RIGHTS RESERVED
The Datalogic name and logo are registered trademarks of Datalogic S.p.A. in many
countries.
The Formula name is a trademark of Datalogic Mobile S.r.l.
All other brand and product names mentioned herein are for identification purposes only
and may be trademarks or registered trademarks of their respective owners.
Datalogic reserves the right to make modifications and improvements without prior
notification.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein,
nor for incidental or consequential damages resulting from the use of this material.
INDEX ............................................................................................... 48
iv
REFERENCES
CONVENTIONS
This manual uses the following conventions:
“User” refers to anyone using a Formula™ mobile computer.
“Mobile computer” and "Formula™" refer to Formula™ mobile computer.
“You” refers to the System Administrator or Technical Support person using this
manual to install, configure, operate, maintain or troubleshoot a Formula™
mobile computer.
REFERENCE DOCUMENTATION
For further information regarding Formula™ refer to the Formula™ SwTools CD.
SERVICES AND SUPPORT
Datalogic provides several services as well as technical support through its
website.
Log on to www.mobile.datalogic.com and click on the
further information including:
- PRODUCTS
Search through the links to arrive at your product page where you can
download specific
Manuals and Software & Utilities
links indicated for
- SERVICES & SUPPORT
- Datalogic Services Warranty Extensions and Maintenance
Agreements
- Authorised Repair Centres
- CONTACT US
E-mail form and listing of Datalogic Subsidiaries
v
SAFETY REGULATIONS
Read this manual carefully before performing any type of
connection to the Formula™ mobile computer.
The user is responsible for any damages caused by incorrect
NOTE
GENERAL SAFETY RULES
− Use only the components supplied by the manufacturer for the specific
− Do not attempt to disassemble the Formula™ mobile computer, as it does
− When replacing the battery pack or at the end of the operative life of the
− Before using the device and the battery pack, see par. 4.3 and read every
− Do not submerge the Formula™ in liquid products.
− The Datalogic Formula™ is designed and labelled to be compliant with
− For further information, refer to this manual and to the Datalogic Mobile
BLUETOOTH®APPROVAL
This product is equipped with the following certified Bluetooth module:
Bluetooth QD ID
POWER SUPPLY
This device is intended to be connected to a UL Listed/CSA Certified computer
which supplies power directly to the reader or else be supplied by a UL
Listed/CSA Certified Power Unit marked “Class 2” or LPS power source rated 5
V, minimum 3.0 A, which supplies power directly to the reader via the power
connector of the cable.
The package includes a EU plug adapter. The EU adapter must be plugged in
the power supply before the power supply itself is plugged on the wall outlet.
use of the equipment or by inobservance of the indication
supplied in this manual.
Formula™ being used.
not contain parts that can be repaired by the user. Any tampering will
invalidate the warranty.
Formula™ mobile computer, disposal must be performed in compliance
with the laws in force.
warnings about the device and the battery pack.
laws, rules and regulations in force in the countries where it is sold.
web site:
www.mobile.datalogic.com.
B011904.
vi
LASER SAFETY
The laser light is visible to the human eye and is emitted from the window
indicated in the figure.
Laser output window
AVOID EXPOSURE
LASER LIGHT
IS EMITTED FROM
THIS APERTURE
This product complies with 21 CFR Subchapter J
CAUTION-CLASS 2 LASER LIGHT WHEN OPEN - DO NOT STARE INTO BEAM
LASER LIGHT - DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAX. OUTPUT RADIATION 2 mW
EMITTED WAVELENGTH 630~680 nm
EN60825-1:2001
I D F E
La luce laser è
visibile all'occhio
umano e viene
emessa dalla
finestra indicata
nella figura.
LUCE LASER
NON FISSARE IL
FASCIO
APPARECCHIO
LASER DI CLASSE 2
MINIMA POTENZA DI
USCITA: 2mW
LUNGHEZZA D'ONDA
EMESSA: 650 nm
CONFORME A EN
60825-1 (2001)
Die Laserstrahlung
ist für das
menschliche Auge
sichtbar und wird am
Strahlaustrittsfenster
ausgesendet (siehe
Bild).
LASERSTRAHLUNG
NICHT IN DER STRAHL
BLINKEN
PRODUKT DER
LASERKLASSE 2
MAXIMALE
AUSGANGLEISTUNG:
2mW
WELLENLÄNGE:
650 nm
ENTSPR. EN 60825-1
(2001)
Le rayon laser est
visible à l'oeil nu et il
est émis par la
fenêtre désignée sur
l'illustration dans la
figure.
RAYON LASER
EVITER DE
REGARDER
LE RAYON
APPAREIL LASER DE
CLASSE 2
PUISSANCE DE
SORTIE: 2mW
LONGUER D'ONDE
EMISE: 650 nm
CONFORME A EN
60825-1 (2001)
La luz láser es
visible al ojo
humano y es
emitida por la
ventana indicada
en la figura.
RAYO LÁSER
NO MIRAR FIJO EL
RAYO
APARATO LÁSER DE
CLASE 2
MÁXIMA POTENCIA
DE SALIDA: 2mW
LONGITUD DE ONDA
EMITIDA: 650 nm
CONFORME A EN
60825-1
(2001)
Laser Light Class II according to CDRH classification
vii
ENGLISH
The following information is provided to comply with the rules imposed by
international authorities and refers to the correct use of your mobile computer.
STANDARD LASER SAFETY REGULATIONS
This product conforms to the applicable requirements of both CDRH 21 CFR
1040 Subchapter J and EN 60825-1:2001 at the date of manufacture.
For installation, use and maintenance, it is not necessary to open the device.
Do not attempt to open or otherwise service any
components in the optics cavity. Opening or servicing
any part of the optics cavity by unauthorized personnel
CAUTION
CAUTION
The product utilizes a low-power laser diode. Although staring directly at the
laser beam momentarily causes no known biological damage, avoid staring at
the beam as one would with any very strong light source, such as the sun.
Avoid that the laser beam hits the eye of an observer, even through reflective
surfaces such as mirrors, etc.
may violate laser safety regulations. The optics system is
a factory only repair item.
Use of controls or adjustments or performance of
procedures other than those specified herein may result
in exposure to hazardous visible laser light.
Use of optical systems with the scanner will increase eye
hazard. Optical instruments include binoculars,
CAUTION
Le seguenti informazioni vengono fornite dietro direttive delle autorità
internazionali e si riferiscono all’uso corretto del terminale.
NORMATIVE STANDARD PER LA SICUREZZA LASER
Questo prodotto risulta conforme alle normative vigenti sulla sicurezza laser alla
data di produzione: CDRH 21 CFR 1040 sezione J e EN 60825-1:2001.
Non si rende mai necessario aprire l’apparecchio per motivi di installazione,
utilizzo o manutenzione.
CAUTION
viii
microscopes, eye glasses and magnifying glasses.
ITALIANO
Non tentare di accedere allo scomparto contenete i
componenti ottici o di farne la manutenzione.
L’apertura dello scomparto, o la manutenzione di qualsiasi
parte ottica da parte di personale non autorizzato, potrebbe
violare le norme della sicurezza. Il sistema ottico può essere
riparato solamente alla fabbrica.
L'utilizzo di procedure o regolazioni differenti da quelle
descritte nella documentazione può provocare
ATTENZIONE
Il prodotto utilizza un diodo laser a bassa potenza. Sebbene non siano noti
danni riportati dall’occhio umano in seguito ad una esposizione di breve durata,
evitare di fissare il raggio laser così come si eviterebbe qualsiasi altra sorgente
di luminosità intensa, ad esempio il sole. Evitare inoltre di dirigere il raggio laser
negli occhi di un osservatore, anche attraverso superfici riflettenti come gli
specchi.
CAUTION
Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die
von internationalen Behörden auferlegt wurden, und sie beziehen sich auf den
korrekten Gebrauch vom Terminal.
NORM FÜR DIE LASERSICHERHEIT
Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825-1:2001
und CDRH 21 CFR 1040 Subchapter J Normen für die Lasersicherheit.
Es ist nicht notwendig, das Gerät wegen Betrieb oder Installations-, und
Wartungs-Arbeiten zu öffnen.
CAUTION
un'esposizione pericolosa a luce laser visibile.
L’uso di strumenti ottici assieme allo scanner può aumentare
il pericolo di danno agli occhi. Tali strumenti ottici includono
cannocchiali, microscopi, occhiali e lenti di ingrandimento.
DEUTSCH
Unter keinen Umständen darf versucht werden, die
Komponenten im Optikhohlraum zu öffnen oder auf
irgendwelche andere Weise zu warten. Das Öffnen bzw.
Warten der Komponenten im Optikhohlraum durch
unbefugtes Personal verstößt gegen die LaserSicherheitsbestimmungen. Das Optiksystem darf nur
werkseitig repariert werden.
Jegliche Änderungen am Gerät sowie Vorgehensweisen,
die nicht in dieser Betriebsanleitung beschrieben werden,
ACHTUNG
Der Produkt benutzt eine Laserdiode. Obwohl zur Zeit keine Augenschäden von
kurzen Einstrahlungen bekannt sind, sollten Sie es vermeiden für längere Zeit in
den Laserstrahl zu schauen, genauso wenig wie in starke Lichtquellen (z.B. die
ix
können ein gefährliches Laserlicht verursachen.
Sonne). Vermeiden Sie es, den Laserstrahl weder gegen die Augen eines
Beobachters, noch gegen reflektierende Oberflächen zu richten.
Die Verwendung von Optiksystemen mit diesem Scanner
erhöht die Gefahr einer Augenbeschädigung.
Zu optischen Instrumenten gehören unter anderem
CAUTION
Les informations suivantes sont fournies selon les règles fixées par les autorités
internationales et se réfèrent à une correcte utilisation du terminal.
NORMES DE SECURITE LASER
Ce produit est conforme aux normes de sécurité laser en vigueur à sa date de
fabrication: CDRH 21 CFR 1040 sous-chapitre J et EN 60825-1:2001.
Il n’est pas nécessaire d’ouvrir l’appareil pour l’installation, l’utilisation ou
l’entretien.
CAUTION
Ferngläser, Mikroskope, Brillen und Vergrößerungsgläser.
FRANÇAIS
Ne pas essayer d’ouvrir ou de réparer les composants de la
cavité optique. L’ouverture de la cavité optique ou la
réparation de ses composants par une personne non
qualifiée peut entraîner le nonrespect des règles de sécurité
relatives au laser. Le système optique ne peut être réparé
qu’en usine.
L'utilisation de procédures ou réglages différents de ceux
donnés ici peut entraîner une dangereuse exposition à
ATTENTION
Le produit utilise une diode laser. Aucun dommage aux yeux humains n’a été
constaté à la suite d’une exposition au rayon laser. Eviter de regarder fixement
le rayon, comme toute autre source lumineuse intense telle que le soleil. Eviter
aussi de diriger le rayon vers les yeux d’un observateur, même à travers des
surfaces réfléchissantes (miroirs, par exemple).
CAUTION
x
lumière laser visible.
L’utilisation d’instruments optiques avec le scanneur
augmente le danger pour les yeux. Les instruments
optiques comprennent les jumelles, les microscopes, les
lunettes et les verres grossissants.
ESPAÑOL
Las informaciones siguientes son presentadas en conformidad con las
disposiciones de las autoridades internacionales y se refieren al uso correcto
del terminal.
NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER
Este aparato resulta conforme a las normativas vigentes de seguridad láser a la
fecha de producción: CDRH 21 CFR 1040 Sección y EN 60825-1:2001.
No es necesario abrir el aparato para la instalación, la utilización o la
manutención.
No intente abrir o de ninguna manera dar servicio a ninguno
de los componentes del receptáculo óptico. Abrir o dar
servicio a las piezas del receptáculo óptico por parte del
CAUTION
ATENCIÓN
El aparato utiliza un diodo láser a baja potencia. No son notorios daños a los
ojos humanos a consecuencia de una exposición de corta duración. Eviten de
mirar fijo el rayo láser así como evitarían cualquiera otra fuente de luminosidad
intensa, por ejemplo el sol. Además, eviten de dirigir el rayo láser hacia los ojos
de un observador, también a través de superficies reflectantes como los
espejos.
personal no autorizado podría ser una violación a los
reglamentos de seguridad. El sistema óptico se puede
reparar en la fábrica solamente.
La utilización de procedimientos o regulaciones diferentes
de aquellas describidas en la documentación puede causar
una exposición peligrosa a la luz láser visible.
El uso de sistemas ópticos con el escáner aumentará el
riesgo de daños oculares. Los instrumentos ópticos incluyen
CAUTION
binoculares, microscopios, lentes y lupas.
RADIO COMPLIANCE
In radio systems configured with mobile computers and access points, the
frequencies to be used must be allowed by the spectrum authorities of the
specific country in which the installation takes place.
Be absolutely sure that the system frequencies are correctly set to be compliant
with the spectrum requirements of the country.
xi
Information for the User
Contact the competent authority responsible for the management of radio
frequency devices of your country to verify any possible restrictions or licenses
required.
Refer to the web site
further information.
Prendi contatto con l'autorità competente per la gestione degli apparati a radio
frequenza del tuo paese, per verificare eventuali restrizioni o licenze. Ulteriori
informazioni sono disponibili sul sito:
Contactez l'autorité compétente en la gestion des appareils à radio fréquence
de votre pays pour vérifier d'éventuelles restrictions ou licences. Pour tout
renseignement vous pouvez vous adresser au site web:
Wenden Sie sich an die für Radiofrequenzgeräte zuständige Behörde Ihres
Landes, um zu prüfen ob es Einschränkungen gibt, oder eine Lizenz
erforderlich ist. Weitere Informationen finden Sie auf der Web Seite:
Contacta la autoridad competente para la gestión de los dispositivos de radio
frecuencia de tu país, para verificar cualesquiera restricciones o licencias
posibles requerida. Además se puede encontrar mas información en el sitio
Web:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm for
ENGLISH
ITALIANO
FRANÇAIS
DEUTSCH
ESPAÑOL
xii
FCC COMPLIANCE
Modifications or changes to this equipment without the expressed written
approval of Datalogic could void the authority to use the equipment.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
DL-FORMULA™ BT LASER Bluetooth model contains transmitter with FCC-ID:
RFR-B2029
SAR COMPLIANCE
This product has been tested and found to comply with the following standards:
- OET BULLETIN 65 SUPPLEMENT C: evaluating compliance with FCC
guidelines for human exposure to radio frequency electromagnetic fields.
- EN 50371:2002: Generic standard to demonstrate the compliance of low
power electronic and electrical apparatus with the basic restrictions related
to human exposure to electromagnetic fields (10 MHz - 300 GHz). General
public
xiii
WIRELESS AND RADIO FREQUENCIES WARNINGS
Use only the supplied or an approved replacement antenna.
Unauthorized antennas, modifications or attachments could
damage the product and may violate laws and regulations.
WARNING
Most modern electronic equipment is shielded from RF signals.
However, certain electronic equipment may not be shielded
against the RF signals generated by Datalogic Formula™.
WARNING
Datalogic recommends persons with pacemakers or other
medical devices to follow the same recommendations provided
by Health Industry Manufacturers Associations for mobile
phones.
WARNING
Persons with pacemakers:
• Should ALWAYS keep this device more than twenty five
(25) cm from their pacemaker and/or any other medical
device;
• Should not carry this device in a breast pocket;
• Should keep the device at the opposite side of the
pacemaker and/or any other medical device;
• Should turn this device OFF or move it immediately AWAY
if there is any reason to suspect that interference is taking
place.
• Should ALWAYS read pacemaker or any other medical
device guides or should consult the manufacturer of the
medical device to determine if it is adequately shielded
from external RF energy.
In case of doubt concerning the use of wireless devices with an
implanted medical device, contact your doctor.
WARNING
WARNING
xiv
Turn this device OFF in health care facilities when any
regulations posted in these areas instruct you to do so.
Hospitals or health care facilities may use equipment that could
be sensitive to external RF energy.
Do not use the device while driving: give full attention to driving
— driving safely is your first responsibility.
The device is not designed to be used with a GPS system. Any
program installed without Datalogic authorization may affect the
device's safety.
WARNING
WARNING
WARNING
RF signals may affect improperly installed or inadequately
shielded electronic systems in motor vehicles. Check with the
manufacturer or its representative regarding your vehicle. You
should also consult the manufacturer of any equipment that has
been added to your vehicle.
An air bag inflates with great force. DO NOT place objects,
including either installed or portable wireless equipment, in the
area over the air bag or in the air bag deployment area. If
vehicle’s wireless equipment is improperly installed and the air
bag inflates, serious injury could result.
Turn off the device when in any area with a potentially explosive
atmosphere. Observe restrictions and follow closely any laws,
regulations, warnings and best practices on the use of radio
equipment near fuel storage areas or distribution fuel areas,
chemical plants or where some operation involves use of
explosive materials.
Do not store or carry flammable liquids, explosive gases or
materials with the device or its parts or accessories.
Areas with a potentially explosive atmosphere are often, but not
always, clearly marked or showed.
Sparks in such areas could cause an explosion or fire, resulting
in injury or even death.
xv
PATENTS
This product is covered by one or more of the following patents.
Design Pat. AU 310182 S; CN 658612; HK 0601962.6; KR 30-0466667; TW
D118829.
US Pat. 5,992,740; European Pat. 789,315 B1.
Additional patents pending.
WEEE COMPLIANCE
Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC
L’apparecchiatura che riporta il simbolo del bidone barrato deve essere
smaltita, alla fine della sua vita utile, separatamente dai rifiuti urbani.
Smaltire l’apparecchiatura in conformità alla presente Direttiva consente di:
evitare possibili conseguenze negative per l’ambiente e per la salute
umana che potrebbero invece essere causati dall’errato smaltimento
dello stesso;
recuperare materiali di cui è composto al fine di ottenere un
importante risparmio di energia e di risorse.
Per maggiori dettagli sulle modalità di smaltimento, contattare il Fornitore dal
quale è stata acquistata l’apparecchiatura o consultare la sezione dedicata sul
sito www.mobile.datalogic.com.
Information for the user in accordance with the European Commission
Directive 2002/96/EC
At the end of its useful life, the product marked with the crossed out wheeled
wastebin must be disposed of separately from urban waste.
Disposing of the product according to this Directive:
avoids potentially negative consequences to the environment and
human health which otherwise could be caused by incorrect disposal
enables the recovery of materials to obtain a significant savings of
energy and resources.
For more detailed information about disposal, contact the supplier that provided
you with the product in question or consult the dedicated section at the website
www.mobile.datalogic.com.
xvi
Information aux utilisateurs concernant la Directive Européenne
2002/96/EC
Au terme de sa vie utile, le produit qui porte le symbole d'un caisson à ordures
barré ne doit pas être éliminé avec les déchets urbains.
Éliminer ce produit selon cette Directive permet de:
éviter les retombées négatives pour l'environnement et la santé
dérivant d'une élimination incorrecte
récupérer les matériaux dans le but d'une économie importante en
Pour obtenir des informations complémentaires concernant l'élimination,
veuillez contacter le fournisseur auprès duquel vous avez acheté le produit ou
consulter la section consacrée au site Web www.mobile.datalogic.com.
Información para el usuario de accuerdo con la Directiva Europea
2002/96/CE
Al final de su vida útil, el producto marcado con un simbolo de contenedor de
bassura móvil tachado no debe eliminarse junto a los desechos urbanos.
Eliminar este producto de accuerdo con la Directiva permite de:
Para obtener una información más detallada sobre la eliminación, por favor,
póngase en contacto con el proveedor donde lo compró o consultar la sección
dedicada en el Web site www.mobile.datalogic.com.
Benutzerinformation bezüglich Richtlinie 2002/96/EC der europäischen
Kommission
Am Ende des Gerätelebenszyklus darf das Produkt nicht über den städtischen
Hausmüll entsorgt werden. Eine entsprechende Mülltrennung ist erforderlich.
Beseitigung des Produkts entsprechend der Richtlinie:
Weitere Informationen zu dieser Richtlinie erhalten sie von ihrem Lieferanten
über den sie das Produkt erworben haben, oder besuchen sie unsere Hompage
unter www.mobile.datalogic.com.
termes d'énergie et de ressources
evitar posibles consecuencias negativas para el medio ambiente y la
salud derivadas de una eliminación inadecuada
recuperar los materiales obteniendo así un ahorro importante de
energía y recursos
verhindert negative Auswirkungen für die Umwelt und die Gesundheit
der Menschen
ermöglicht die Wiederverwendung der Materialien und spart somit
Energie und Resourcen
xvii
CHINA ROHS POLLUTION CONTROL LOGOS
Part
name
Upper
Case
Lower
Case
Touch
Panel
PCB
Board
Laser
Engine
BT
Module
(Note 1)
O: Indicates that this is a toxic or hazardous substance contained in all of the
homogenous materials for this part is below the limit requirement in
SJ/T11363-2006.
X: Indicates that this is toxic or hazardous substance contained in at least
one of the homogeneous materials used for this part is above the limit
requirement in SJ/T11363-2006.
Note 1: this is only for DL-FORMULA™ BT LASER Model.
Note 2: 99% of the parts of this product adopt the nonpoisonous and
harmless environmental protection material to make, the part with
poisonous harmful substance or the element is all unable to realize
the substitution of the poisonous harmful thing or the element
because the global technological development level is limited.
Toxic or Hazardous Substances and Elements
Pb Hg Cd Cr6+ PBB PBDE
O O O O O O
O O O O O O
O O O O O O
O O O O O O
X O O O O O
O O O O O O
xviii
GENERAL VIEW
B
C
K
A
H
D
G
F
A) FSTN Transflective LCD B/W
Led Backlight
B) Good Read or User
Programmable LED
C) Charging Status LED
D) User Programmable LED
E) Scan Key
L
L) Data Capture/Laser Output
Window *
M) DC Charger Connector
• Remove protective film cover before use.
E
I
J
F) Keyboard
G) Radio Status LED
H) Laser Safety Label
I) Product Label
J) Battery Pack
K) ON/OFF Power Key
N) Communication/Charger Connector
(through cradle); Serial
Connector (through cable)
O) Mini USB Communication
Connector (through cable)
(under battery)
N
M
O
xix
xx
INTRODUCTION
1
1 INTRODUCTION
1.1 FORMULA™ DESCRIPTION
The Formula™ combines fast, accurate barcode scanning and communications
options in a small and ergonomic package.
It is ready to use out of the box, as the product is provided with a power supply
and USB cable.
Easy to install, lightweight, and cost-effective, the Formula™ is built to work
hard through long shifts.
It also makes your work easy and efficient in any condition thanks to its
rechargeable Li-Ion battery.
A set of connectors placed on the bottom of the terminal make it always ready
to be connected or to recharge the battery.
The Formula™ pocket terminal includes standard technologies: USB and
Bluetooth (optional) allow it to be connected to many infrastructures.
An easy-to-read backlit LCD screen displays all the information needed during
customer applications in any light condition.
The Formula™: the largest advantages in a very small package!
1.2 AVAILABLE MODELS
The brand new Formula™ is available in different models depending on the
options it is equipped with. All options are listed below:
• communication options: Bluetooth®
• capture options: Laser
For further details about the Formula™ models refer to the web site:
http://www.mobile.datalogic.com.
1
1
FORMULA™
1.3 PACKAGE CONTENTS
The Formula™ package contains:
− 1 Formula™ mobile computer
− 1 AC/DC power supply USA Plug
− 1 AUS Plug Adapter
− 1 UK Plug Adapter
− 1 EU Plug Adapter
− 1 standard Mini USB cable
− 1 CD-ROM containing:
Formula
− 1 user’s manual
− 1 quick starting guide
− 1 rechargeable standard 1000 mAh battery pack + cover
− 1 hand-strap
Any other packages will contain the accessories necessary for the Formula™
connection to the host computer and to the network: the cradle, one or more
connection cables.
Remove all the components from their packaging; check their integrity and
congruity with the packing documents.
TM
Software Tools installation software
The complete documentation and all manuals in PDF format
See chapter 3.1 “Formula™ Software Tools Overview” for further
details
CAUTION
NOTE
2
Keep the original packaging for use when sending products
to the technical assistance center. Damage caused by
improper packaging is not covered under the warranty.
Rechargeable backup batteries and battery packs are not
initially charged. Therefore the initial operation to perform is
to charge them. See paragraphs 4.1 and 4.2.
INTRODUCTION
1
1.4 INSERTING AN SD CARD
Formula™ provides the possibility to add an SD Formula™ storage card. To
access the SD card slot and insert the card, proceed as follows:
1. Extract the SD card slot cover from the side of the mobile computer.
Then carefully pull it out to unlock its base as shown in the picture
below:
2. Insert the card with the written part upward and push it in, aided by
the back of a pen, until it clicks into place.
To remove the SD card, just push it toward the inside, aided by the back of a
pen, until it clicks; a spring system will return it out.
3
1
CAUTION
NOTE
FORMULA™
Follow proper ESD precautions to avoid damaging the SD.
Proper ESD precautions include, but are not limited to, working
on an ESD mat and ensuring that the operator is properly
grounded.
Do not force the card. If you feel resistance, remove the card,
check the orientation, and reinsert it.
Do not use the SD card slot for any other accessories.
Only MMC/SD with FAT 16 format are supported.
4
INTRODUCTION
1.5 ACCESSORIES
Cradles
94A151111 Datalogic Memor™ single cradle with spare battery slot;
RS232 and USB communications
94ACC1327 Adapter for 3 AAA Alkaline batteries + cover
Power Supply
94ACC1324PG5-30P35 AC/DC Power Supply USA Plug
94ACC1334 PG5-30P35 AUS Plug Adapter (10pcs)
94ACC1335 PG5-30P35 UK Plug Adapter (10pcs)
94ACC1339 PG5-30P5 EU Plug Adapter (10pcs)
Cables
94A051016 CAB-421 Mini USB Straight Cable
94A051022 WIN-NET Serial Cable (HRS ST40X-18S-CV)
1
Use only a Datalogic Mobile-approved power supply and cables.
Use of an alternative power supply will invalidate any approval
given to this device and may be dangerous.
NOTE
5
2
A
A
FORMULA™
2 CONNECTIONS
2.1 USB CONNECTION
You can use any standard mini USB cable to directly connect the Formula™ to
a host computer to transfer data through the USB interface.
B
Key:
A Host computer C Formula™
B Standard mini USB cable
The single cradle can be connected to the Host by any standard mini USB cable
to transfer data through the USB interface.
C
B
Key:
A Host computer C Single cradle
B Standard mini USB cable D *Power supply (only necessary
for battery charging)
In this case the power supply is only necessary for battery charging. Insert the
power supply plug into the power jack on the base of the cradle and attach the
power supply to a power outlet.
D*
C
6
CONNECTIONS
A
A
2
2.2 RS232 CONNECTION
You can use a cable to directly connect the Formula™ to a host computer to
transfer data through the RS232 interface.
B
Key:
A Host computer C Formula™
B 94A051022 WIN-NET
(HRS ST40X-18S-CV)
The single cradle can be connected to the Host by any standard 9-pin serial
null-modem cable for RS232 communications.
Once the Host has been turned on, insert the Formula™ mobile computer into
the cradle.
Key:
B
D
C
C
A Host computer C Single cradle
B 94A051020 CAB-427
Null-Modem
In this case the power supply is only necessary for battery charging. Insert the
power supply plug into the power jack on the base of the cradle and attach the
power supply to a power outlet.
7
D Power supply (only necessary for
battery charging)
2
2.3 BLUETOOTH® CONNECTIONS
Bluetooth
Bluetooth
®
Formula™ mobile computer models can be connected to a
®
host device with a point to point connection.
B
A
FORMULA™
Key:
A) Formula™
B) Host computer with Bluetooth® connectivity
8
CONNECTIONS
T
2.4 CONNECTION CABLES
The following cable contains its order number.
RS232 Direct Connection:
94A051022 WIN-NET SERIAL CAB (HRS ST40x-18S-CV)
Datalogic
Formula™ Side
Power Supply Polarity:
RXD
9
TXD
10 2
CTS
11
RTS
12 8
DSR
13
DCD
15
14
DTR
RI
8
GND
7
DCD
DSR
RI
GND
VEX
TXD
RXD
RTS
CTS
DTR
HOST/PC Side
9-pin (female)
3
7
4
1
6
9
5
2
GND
9
3
FORMULA™
3 USE AND FUNCTIONING
Formula™ is a lightweight, pocket-sized and fully programmable terminal with
1024 KB of RAM memory to manage large databases and 512 KB of Flash
memory for application programs of large dimensions.
3.1 FORMULATM SOFTWARE TOOLS OVERVIEW
The CD-ROM Formula
terminal.
It includes:
- Formula
- the complete documentation and all manuals in PDF format.
TM
Software Tools installation software
3.1.1 FormulaTM Software Tools Components
The Formula
categories:
Development
Communication
Ready-To-Use Applications
TM
SW TOOLS components are grouped in the following three main
SW Developer’s Toolkits (DS for Formula™)
EasyGen™
OleForFormula™
Systools™
Standard Mode M1
Enhanced Mode M2
PALPRO
3.1.2 FormulaTM Software Tools Installation
The installation software allows to install the Formula
components according to three different types of installation:
- User
- Developer
- Custom
TM
SW TOOLS contains the software for FormulaTM
TM
SW TOOLS
10
USE AND FUNCTIONING
3
The following table specifies which components can be installed for each type of
installation:
Formula
SW Developer’s Toolkits
TM
SW TOOLS
Component
User
Installation
Developer
Installation
Custom
Installation
No Yes Yes/No
(DS for Formula™)
EasyGen™ No Yes Yes/No
SysTools™ Yes Yes Yes/No
OLE for Formula™ No Yes Yes/No
Ready-To-Use Applications Yes Yes Yes/No
3.1.3 SW Developer’s Toolkits Component Overview
The Software Developer’s Toolkits component is the DS for Formula™
environment for developing custom applications with the 8051 Keil Compiler.
A set of Workdemo examples source code is installed together with this
component.
DS for Formula™ is a software package that provides instruments for fully
exploiting Formula™ terminals by creating fully-structured and personalized
applications.
DS for Formula™ can be used to:
- generate applications for new Formula™ terminal;
- re-generate applications developed for old Formula™ terminals to let them
run on new Formula™ terminal.
The DS for Formula™ distributed with this product can not generate
applications for old Formula™ terminals.
For compatibility and portability details see SW Dev Toolkits Developer’s
Manual Vol2. Section A.
DS for Formula™ uses a «C» standard ANSI compiler, integrated with special
libraries, operating in a MS-DOS environment and developed specifically for the
type of terminal processor. The libraries, developed by Datalogic Mobile S.r.l.,
permit direct management of the terminal functions. For example, the
management of barcode reading devices is immediate and rational thanks to
the interaction with functions that automatically start up the barcode acquisition
procedure.
Equally transparent, by using a philosophy of events programming, is the
procedure managing the keyboard, display, serial and radio-frequency
communication, calendar/clock and the data memory organized into banks,
either directly or through a vdisk function.
DS for Formula™ also offers a series of effective general purpose application
examples, which represent an excellent starting point while simultaneously
providing a practical guide for studying and working on complex or personalized
programs. Refer to the SW Dev Toolkits Developer’s Manual for details.
11
3
Software required on Host Computer
COMPONENT SOFTWARE
DS for Formula™ Refer to chapter 1.2 of
8051 Keil
Compiler V8
INSTALLATION
this manual
Refer to Keil Compiler
installation
FORMULA™
DOCUMENTATION
Refer to SW Dev Toolkits
Developer’s Manual for further
information
Refer to compiler
documentation
SysTools™ Refer to chapter 1.2 of
Software required on Formula™ Terminal
COMPONENT SOFTWARE USE DOCUMENTATION
Custom
Application
development
Custom
Application
download
Data transfer
this manual
1.
Create an application or
select a Workdemo example
installed together with DS for
Formula™
2.
Compile the application
3.
Download the developed
Custom Application through
SysTools™ host computer
application
4.
After data collection you can
transfer data to host
computer using the
programmed communication
interface on the host
computer
Refer to SysTools™ user’s
manual for further information
For environment setup,
application development
and Workdemo examples
refer to SW Dev Toolkits
Developer’s Manual
Refer to SysTools™ user’s
manual for further
information
For Workdemo examples
type of communication
interface refer to SW Dev
Toolkits Developer’s
Manual
12
USE AND FUNCTIONING
Host Computer
Host Computer Formula™
3
1./2. develop custom application
3. download custom
application
Host Computer
4. transfer collected
data to PC
13
Formula™
3
NOTE
FORMULA™
Downloading an executable file not generated with the DS for
Formula™ Rel 2.00 or later release can damage the device!
Application programs developed for other Formula™ devices are
not compatible at execution level, they
Ds for Formula™ Rel 2.00 or later releases.
Correct functioning and behaviour of the terminal is guaranteed
only under these conditions.
must be recompiled with
14
USE AND FUNCTIONING
3
3.1.4 EasyGen™ Component Overview
EasyGen™ component is a rapid Application Generator to generate easy and
quick Applications running on Formula™ device.
A set of ready-to-use EasyGen™ Application examples are installed together
with this component. These are the most common application examples (data
collection, inventory, goods picking, assisted sales) available in 5 languages
(English, French, German, Italian, Spanish).
By using the EasyGen™ application generator, developers can easily customize
applications according to the end user’s specific needs, solving the most
common data collection applications such as inventory, picking and
shipping/receiving.
EasyGen™ is the ideal solution for making Formula™ batch terminals
productive instantly. In a familiar environment, developers have all the
instruments at their disposal to reduce programming times (and therefore costs)
while maintaining a high standard of quality in the creation of personalized
applications whatever their nature, whether simple (e.g. a program for inserting
codes/quantities) or more sophisticated.
Software required on Host Computer
COMPONENT SOFTWARE
EasyGen™ Refer to chapter 1.2 of
INSTALLATION
this manual
DOCUMENTATION
Refer to EasyGen™ user’s
manual for further information
SysTools™ Refer to chapter 1.2 of
this manual
15
Refer to SysTools™ user’s
manual for further information
3
Software required on Formula™ Terminal
COMPONENT SOFTWARE
EasyGen™
Interpreter
EasyGen™
Application
Data transfer
INSTALLATION
The interpreter
is installed on
the host
computer
together with
EasyGen™
component
Examples of
applications
ready to use are
installed on the
host computer
together with
EasyGen™
component
installation
New
applications can
be created with
EasyGen™.
SOFTWARE
1.
Download the
EasyGen™
Formula™
interpreter
through
EasyGen™ host
computer
application.
Alternatively you
can download it
through
SysTools™ host
computer
application
2.
Download the
EasyGen™
Formula™
application
through
EasyGen™ host
computer
application.
Alternatively you
can download it
through
SysTools™ host
computer
application
3.
Collect data on
the terminal
4.
Configure
SysTools™
Startup Mode in
EasyGen Mode
5.
Transfer data to
host computer
via SysTools™
FORMULA™
DOCUMENTATION
USE
Refer to
EasyGen™ or
SysTools™ user’s
manual for further
information
Refer to
EasyGen™ user’s
manual for
installation folder of
Formula™
Interpreter
Refer to
EasyGen™ or
SysTools™ user’s
manual for further
information.
Refer to
EasyGen™ user’s
manual for
installation folder of
Applications
examples
Refer to
SysTools™ user’s
manual for further
information
16
USE AND FUNCTIONING
3
Host Computer
1. download
EasyGen™ interpreter
Host Computer
2. download
EasyGen™ application
Formula™
Formula™
Host Computer
5. transfer collected
data to PC
17
Formula™
3
FORMULA™
3.1.5 SysTools™ Component Overview
SysTools™ is an efficient software utility to download application to Formula™
terminal, to exchange data with the terminal and to transfer data to standard
ASCII files on the host computer through Serial or USB interface.
Refer to the SysTools™ user’s manual for further details.
3.1.6 OLE for Formula™ Component Overview
OLE for Formula™ is the software module ActiveX - OLE Custom Control or
OCX, allowing users to easily integrate their data into applications such as
Visual Basic, Excel, Access, Delphi, etc.
Refer to the OLE for Formula™ reference manual for further details.
This component includes Standard Mode M1, Enhanced Mode M2 and
PALPRO (Portable Application Library) ready-to-use applications.
Standard Mode M1 application is a Code-Quantity application allowing data
received from Formula™ terminal to be stored in a default record format.
Enhanced Mode M2 application is a fully configurable application for creating
typical Asset Management or Inventory applications. Data received from
Formula™ terminal are stored in a customized record format and specific
checks can be made on each item data. Record format can be programmed
with SysTools™ .
PALPRO combines two Portable Applications Library (PAL) applications,
AssetPRO and INVPRO, into a single, convenient program:
use ASSETPRO to track assets (such as furniture, phones, computers, and
electronic equipment) at various locations (e.g., departments, rooms, floors,
buildings);
use INVPRO to track inventory. IT provides a choice of one prompt or
two.
Software required on Host Computer
COMPONENT SOFTWARE
Standard Mode M1
or
Enhanced Mode M2
SysTools™ Refer to chapter 1.2 of
PALPRO Refer to chapter 1.2 of
INSTALLATION
Refer to chapter 1.2 of
this manual
this manual
this manual
DOCUMENTATION
Refer to Ready-to-Use
Applications user’s
manual for further
information
Refer to SysTools™
user’s manual for further
information
Refer to Datalogic
Formula™ Quick
Reference Guide for
further information
18
USE AND FUNCTIONING
Software required on Formula™ terminal for Standard Mode M1
COMPONENT SOFTWARE USE DOCUMENTATION
3
Standard Mode
M1
Executable
Applications
Data Transfer
1.
Configure SysTools™ Startup
Mode in Standard/Enhanced
Mode
2.
Download the Standard Mode
executable Files from host
computer to Formula™ through
SysTools™
3.
Collect data on the terminal
4.
Transfer data to PC via
SysTools™
Host Computer Formula™
2. download
Standard Mode M1/
PALPRO
Refer to SysTools™
user’s manual for
further information
Host Computer
4. transfer collected
data to PC
19
Formula™
3
Software required on Formula™ terminal for Enhanced Mode M2
COMPONENT SOFTWARE USE DOCUMENTATION
FORMULA™
Enhanced Mode M2
Executable
Applications
Record
customization
Data Transfer
1.
Configure SysTools™ Startup
Mode in Standard/Enhanced
Mode
2.
Download the Enhanced Mode
executable Files from host
computer to Formula™ through
SysTools™
3.
Create tables for record
customization and download
tables through SysTools™
4.
Collect data on the terminal
5.
Transfer data to PC via
SysTools™
Refer to SysTools™
user’s manual for
further information
Refer to Ready-toUse Applications
user’s manual for
further information
20
USE AND FUNCTIONING
3
Host Computer
2. download
Standard Mode M2
Host Computer
3. download
tables with
record format
Host Computer
Formula™
Formula™
Formula™
5. transfer collected
data to PC
21
3
FORMULA™
3.2 APPLICATION PROGRAM
PALPRO application program is pre-loaded.
For further information, refer to Datalogic Formula™ Quick Reference Guide.
22
USE AND FUNCTIONING
3
3.3 DELETING AND LOADING THE APPLICATION
PROGRAM
This procedure allows deleting application programs developed with DS for
Formula™. If you want to delete programs provided or developed by
EasyGen™, refer to chapter 6 of the EasyGen™ manual.
The following procedure causes data to be deleted even if not
completed.
NOTE
To delete the application program, follow the instructions below:
1- Press the <SCAN> key and the ON/OFF power key simultaneously; the
display will show:
If you do not want to delete the application program, press the
{▲} key or wait about 25 seconds.
NOTE
2- To continue with the deletion, press the ▼ key; after a few seconds, the
display will show:
Select one of the boot mode options by pressing the following keypad buttons:
- Press 1 to select download via USB cable connection.
- Press 2 to select download via MMC/SD card.
- Press 3 to select download via serial cable connection.
PROGRAM
ERASE?
Up = No Down = Yes
Boot from:
1. USB
2. MMC
3. Serial
23
3
After the boot mode selection the display will show:
BOOTSTRAP-
LOADER
ErasPrgFlash
FORMULA™
Once the deletion procedure is completed, the terminal is ready to receive a
new application program.
If download via USB has been selected, the display will show:
BOOTSTRAP-
LOADER
WaitDownload USB
If download via MMC/SD has been selected, the display will show:
BOOTSTRAP-
LOADER
WaitDownload MMC
Check if card is:
-Correctly inserted
-FAT16 formatted
-The file to download is present on the card with the correct filename and
extension.
File name must be DS_OUT. File extension is .HEX in case of single bank
application or .HXX in case of a multi-bank application.
If download via serial connection has been selected, the display will show:
BOOTSTRAP-
LOADER
WaitDownload Ser
Application program download via USB or via RS232 can be done using
SysTools™ program or EasySend™ program. For details, see SysTools™
User’s Manual and SW Dev Toolkits Developer’s Manual.
24
USE AND FUNCTIONING
3
3.4 DOWNLOADING DATA TO HOST
Data can be downloaded from the terminal to the host PC in different ways,
depending on the application loaded and on the terminal model.
The application software allows to download data onto the host PC by simply
inserting the terminal into the cradle, by inserting cables directly into the
terminal or by direct operator intervention on the terminal or on the host
computer.
Figure 1 - Downloading Data RS232
Three different uses of USB connection can be configured at application level:
- USB mass storage
- USB serial emulation
- USB Keyboard
For more details, refer to SW Dev Toolkits Developer’s Manual and SDK.
25
Figure 2 - Downloading Data USB
3
FORMULA™
If working with Bluetooth model, the application software can also allow to
download data by radio frequency transmission between the terminal and a
Bluetooth host device.
Figure 3 - Downloading Data Bluetooth
®
26
USE AND FUNCTIONING
3
3.5 DATA CAPTURE
3.5.1 Laser Data Capture
To scan barcodes, point the Formula™ laser model onto the code from a
distance within the reading range while pressing the SCAN key.
The lighted band emitted by the laser must completely intercept the barcode as
shown in the figure below. If enabled, the emission of an acoustic signal will
indicate that the scan has taken place correctly.
Remove the protective film cover over the Laser Output
Window before use.
NOTE
27
3
FORMULA™
3.6 DESCRIPTION OF THE KEYS USING EASYGEN™
It is possible to assign customized functions to function keys depending on the
application program developed. The functions described below refer to a
terminal using an application program developed with the EasyGen™
Application Generator.
Refer to chapter 6 "EasyGen™ Interpreter
Program" of the EasyGen™ User's Manual for
more details about the key functions.
Every time a key is pressed, the Formula™
terminal remains turned on for a maximum of 20
seconds.
ARROW KEYS: only available for the application when
not in “Select or Data Edit” mode.
SCAN KEY: activates the laser for barcode scanning
and turns on the terminal when it is off.
FUNCTION KEYS: keys <F1>, <F2>, <F3> and <F4>
are available for the loaded application. Function F5
activates the “Select” mode and only in this mode you
can use F6, F7 and F8 functions:
<SHIFT> followed by <F1> = F5 “Select” mode
<SHIFT> followed by <F2> = F6 Data search
<SHIFT> followed by <F3> = F7 Deletion
<SHIFT> followed by <F4> = F8 Data display.
ESC KEY: used in the “Data display” mode.
POWER DOWN AND RESUME: by pressing the
<ON/OFF> power key, the system is brought to a
power-down state; press the <ON/OFF> power key
again to resume.
CAUTION
NOTE
28
USE AND FUNCTIONING
SHIFT KEY: Enables the entry of alphabetical
characters (written in white on the keyboard) when
followed by the pressing of a numeric key: for example
if you want to enter the alphabetical character “A”, you
have to press: <SHIFT>+<7>.
The number of times the SHIFT key is pressed
determines the choice of alphabetical character: for
example if you want to enter the alphabetical character
“N”, you have to press <SHIFT>+<SHIFT>+<5>, if you
want to enter the alphabetical character “X”, you have to
press:
<SHIFT>+<SHIFT>+<SHIFT>+<2> and so on.
The fourth time the SHIFT key is pressed, the SHIFT
function is disabled. The SHIFT function can also be
disabled by waiting for a time-out of 2 seconds after
being pressed.
By pressing the <SHIFT> key followed by the <RIGHT
ARROW> key, the graphic display’s contrast increases
to the allowed maximum, and then returns to 0 value.
NUMERIC KEYS: allow the entry and display of the
main numeric symbol. If the <SHIFT> has first been
pressed, the choice of alternative alphabetic characters
will be activated.
3
29
BACKSPACE KEY: deletes the last character entered.
SPACE KEY: allows the introduction of a blank space. If
the <SHIFT> has been pressed previously, the choice
of alternative characters will be activated.
ENTER KEY: allows validation of what has been typed.
RESET: by pressing <SCAN> + <ON/OFF> keys
simultaneously, a system reset is performed.
3
FORMULA™
3.7 STATUS INDICATORS
3.7.1 LED Status
The Formula™ provides four different LEDs signaling the mobile computer
status.
LED STATUS
Good Read and
General Purpose
(left side)
Green/Red It is also available to the application
Charging Status
(right side)
Red constant It is constant while charging.
Radio Status
(on the upper left
side of the arrow
keys)
Application
Programmable
Status (on the upper
right side of the
arrow keys)
Green
Green constant It is constant once the charging
Blue It blinks once Radio Bluetooth status
Orange User programmable LED
It is constant for a configurable time
to signal that a successful read has
occurred.
program.
process has been completed.
is active.
30
USE AND FUNCTIONING
3
3.7.2 Taskbar
The Taskbar provides information about the time, the battery level, the keyboard
function, and the decoding status.
The first row of the display is used to manage the taskbar and can display the
following icons:
ICONS DESCRIPTION
Time icon
Battery icon. Displays battery charge status
Mail icon
NOTE
Transmission icon
Phone icon
Bell icon
Bluetooth icon
USB icon
MMC/SD icon
DC-IN icon
KEY icon
Use and display of all icons can be controlled directly by
application program, except for battery icon, time icon and DCIN icon that are controlled directly by operating system.
31
4
FORMULA™
4 MAINTENANCE
Rechargeable backup batteries and battery packs are not
initially charged. Therefore the initial operation to perform is
to charge them. See below.
NOTE
By default, the backup battery is disconnected at the factory
to avoid damage due to excessive draining. If it is not
connected (through the backup battery switch) and
CAUTION
4.1 CONNECTING THE BACKUP BATTERY
The backup battery must be connected by putting the switch in the "connected"
position. It will be charged together with the battery pack through the normal
charging process.
It is only necessary to disconnect the backup battery if it will not be used for a
long period of time (i.e. several weeks).
subsequently charged together with the battery pack, all
data will be lost when changing the battery pack.
Annual replacement of rechargeable battery pack avoids
possible risks or abnormalities and ensures maximum
performance.
CAUTION
32
CONNECTED
DISCONNECTED
Be careful when using sharp-edged tools to move the
switch from the “disconnected” position to the "connected"
position and vice versa!
MAINTENANCE
4
4.2 CHARGING THE BATTERY PACK
The battery pack autonomy varies according to factors such as the frequency of
barcode scanning, RF usage, etc.
The battery icon on the Taskbar indicates when the battery pack is low.
It is possible to recharge the battery pack by connecting the power supply
directly to the Formula™.
Alternatively, it is also possible to recharge the battery pack by using the
Formula™ single cradle.
During the charging process the LED positioned at the right side of the display
is red constant. Once the charging process has been completed this LED is
green constant (see par. 3.7).
If the battery pack is removed from the mobile computer, it can be recharged by
inserting it into the rear slot of the Formula™ single cradle.
The battery pack autonomy varies according to many factors,
such as the frequency of barcode scanning, RF usage, battery
life, storage, environmental conditions, etc.
NOTE
If the battery pack is new or has not been recharged for a
long time, it is necessary to perform two or three charging
and discharging cycles (complete use) before it can reach
its maximum charge capability.
The maximum time required to recharge a completely run-
CAUTION
NOTE
down battery pack is about 3 hours if the mobile computer
is idling.
Even if the storage temperature range is wider, In order to
achieve the longest battery life, store the terminal and the
spare batteries between 20 to 30 ºC (68 to 86 ºF).
The Batteries must be charged at a temperature ranging
from 0° to +45 °C (+32° to +113 °F).
33
4
FORMULA™
4.3 REPLACING THE BATTERY PACK
To correctly replace the battery pack, proceed as follows.
1. Turn off the Formula™.
2. Use a screw driver to rotate the battery cover screw to the vertical position,
then push the battery clips in, as indicated in the figure below. The battery
pack cover is now released.
3. Remove the cover and then the battery pack.
34
Battery Contacts
MAINTENANCE
4. Install the new battery pack, first insert the bottom (contacts) side, then the
upper (lock) side as indicated in the following figure:
4
5. For correct locking, push the battery clips outwards and rotate the screw to
the horizontal position.
35
4
WARNING
FORMULA™
To install, charge and/or do any other action on the battery,
follow this manual.
The battery pack may get hot, explode, ignite, and/or cause
serious injury if exposed to abusive conditions.
If the battery pack is replaced with an improper type, there is risk
of explosion.
Do not place the battery pack in or near a fire or heat; do not
place the battery pack in direct sunlight, or use or store the
battery pack inside unventilated areas in hot weather; do not
place the battery pack in microwave ovens, dryer, high pressure
containers, on induction cookware or similar device. Doing so
may cause the battery pack to generate heat, explode or ignite.
Using the battery pack in this manner may also result in a loss of
performance and a shortened life expectancy.
Use only a Datalogic Mobile approved power supply. The use of
an alternative power supply will void the product warranty, may
cause product damage and may cause heat, explode or ignite.
The area in which the units are charged should be clear of debris
and combustible materials or chemicals.
Do not use the battery pack of this terminal for power devices
different from this mobile computer.
Immediately discontinue use of the battery pack if, while using,
charging or storing the battery pack, the battery pack emits an
unusual smell, feels hot, changes colour or shape, or appears
abnormal in any other way.
Do not short-circuit the battery pack contacts connecting the
positive terminal and negative terminal. This might happen, for
example, when you carry a spare battery pack in your pocket or
purse; accidental short–circuiting can occur when a metallic
object such as a coin, clip, or pen causes direct connection of
the contacts of the battery pack (these look like metal strips on
the battery pack). Short–circuiting the terminals may damage the
battery pack or the connecting object.
Do not apply voltages to the battery pack contacts.
Do not pierce the battery pack with nails, strike it with a hammer,
step on it or otherwise subject it to strong impacts or shocks.
Do not disassemble or modify (i.e. bend, crush or deform) the
battery pack. The battery pack contains safety and protection
devices, which, if damaged, may cause the battery pack to
generate heat, explode or ignite.
36
MAINTENANCE
In case of leakage of liquid from the battery, avoid contact with
liquid the skin or eyes. If the contact occurs, immediately wash
the affected area with water and consult a doctor.
WARNING
NOTE
Do not solder directly onto the battery pack.
Do not expose the battery pack to liquids.
Avoid any knocks or excessive vibrations. If the device or the
battery is dropped, especially on a hard surface, you should take
it to the nearest Authorised Repair Centre for inspection before
continuing to use it.
Do not replace the battery pack when the device is turned on.
Do not remove or damage the battery pack’s label.
Do not use the battery pack if it is damaged in any part.
Battery pack usage by children should be supervised.
Collect and recycle waste batteries separately from the device
in comply with European Directive 2006/66/EC, 2002/95/EC,
2002/96/EC and subsequent modifications, US and China
regulatory and others laws and regulations about environment.
4
In order to guarantee an adequate operating autonomy,
when replacing the battery pack the mobile computer
checks the battery energy level. If the battery is not
sufficiently charged, Formula™ does not turn on (when
pressing the ON/OFF key).
In this case, either substitute the battery pack with a
charged one (sufficiently charged) or insert Formula™ into a
powered cradle or plug it into the direct power supply.
If alkaline batteries are used, the operating autonomy may
vary according to operating conditions and battery
manufacturer.
To achieve the best battery life, turn off the radios not in
use.
NOTE
4.4 CLEANING THE MOBILE COMPUTER
Periodically clean the Formula™ with a slightly dampened cloth.
Do not use alcohol, corrosive products or solvents.
37
5
FORMULA™
5 TROUBLESHOOTING
PROBLEM CAUSE REMEDY
button is pressed the
terminal does not come
on.
button is pressed, the
terminal displays the
message BATTERY
LOW and switches itself
off.
Flat batteries. Recharge terminal. When the <SCAN>
Batteries completely flat
or broken.
Flat batteries. Recharge terminal. When the <SCAN>
Batteries completely flat
or broken.
Replace batteries.
Replace batteries.
The terminal does not
load the application
program.
You are downloading via
serial communication and
the serial cable is not
correctly connected.
You are downloading via
USB communication and
the USB cable is not
correctly connected.
You are downloading via
MMC/SD.
The terminal already
contains an application
program.
Check the serial
connection on the
terminal or on the cradle
and the serial port of the
host.
Check the USB
connection on the
terminal or on the cradle
and the USB port of the
host.
Check if card is:
-Correctly inserted
-FAT16 formatted
-The file to download is
present on the card with
the correct filename and
extension. File name
must be DS_OUT. File
extension is .HEX in
case of single bank
application or .HXX in
case of a multi-bank
application.
Follow instructions to
cancel the application.
38
TROUBLESHOOTING
PROBLEM CAUSE REMEDY
The terminal displays
an error message
FAULT CODE.P21CO4.
The application loaded is
not suitable for the terminal
in use. The terminal
displays the message
FAULT CODE P21CO4.
Other faults. The terminal
displays an error message
other than FAULT CODE
P21 CO4.
Load the correct
application program.
Contact your Datalogic
Mobile representative
for technical
assistance.
5
39
6
FORMULA™
6 TECHNICAL FEATURES
6.1 TECHNICAL DATA
Electrical Features
Power
DC Supply 5 V ± 5%
Battery Pack 1 cell Li-Ion 1000 mAh@3.7 V (nominal)
Internal Backup Battery Rechargeable Ni-MH 15mAh@.2.4 V
Communication Features
Bluetooth Interface SPP Profile on COM defined by host
Serial Interface RS232
Environmental Features
Working Temperature* 0° to +50 °C / 32 °F to +122 °F
Storage Temperature -20° to +70 °C / -4° to +158 °F
Humidity** 10 to 80% non condensing
Protection IP 54
ESD Protection 4 KV contact discharge, 8 KV air discharge
Drop Resistance*** 1.2 m / 3 ft 9 in
Hardware Features
FLASH 512 KB
RAM 1 MB
Microprocessor 8-bit CMOS
Audio Beeper
LEDs Two-color Good Read/Programmable
Display FSTN Transflective 2.2” B/W LCD with LED
Keyboard 25 Plastic Top + lateral ON/OFF key
Mechanical Features
Dimensions (LxWxH) 15.2 x 5.5 x 4.0 cm / 5.9 x 2.2 x 1.6in
Weight
(depending on model)
* Battery must be charged at a temperature ranging from 0° to +45 °C.
Close to the limits of the working temperature, some display and/or battery performance
degradation may occur.
** Multiple rapid humidity and/or temperature variations may cause condensing.
*** Multiple drops can permanently damage the device.
Formula™ Common Features
Alternatively 1 cell Li-Ion 2000 mAh@3.7 V
(nominal)
USB 1.1
for temperatures < 38 °C
Charging Status
Radio Status
Application Programmable Status
backlight, 16 lines by 16 characters, antiglare
and antiscratch protection
206 g / 7.27 oz (incl. 1000 mAH battery)
226 g / 7.97 oz (incl. 2000 mAH battery)
40
TECHNICAL FEATURES
Programming Features
Operating System Proprietary
Operating Modes Bootstrap loader; application program
LaserModels
Decoded barcodes TBD Standard 3/9
A pattern of variable-width bars and spaces which represents numeric or
alphanumeric data in binary form. The general format of a barcode symbol
consists of a leading margin, start character, data or message character, check
character (if any), stop character, and trailing margin. Within this framework,
each recognizable symbology uses its own unique format.
Baud Rate
A measure for data transmission speed.
Bit
Binary digit. One bit is the basic unit of binary information. Generally, eight
consecutive bits compose one byte of data. The pattern of 0 and 1 values within
the byte determines its meaning.
Bluetooth®
A standard radio technology using a proprietary protocol. The onboard
Bluetooth module in the mobile computer is compatible with the 1.1 protocol.
Byte
On an addressable boundary, eight adjacent binary digits (0 and 1) combined in
a pattern to represent a specific character or numeric value. Bits are numbered
from the right, 0 through 7, with bit 0 the low-order bit. One byte in Formula™
can be used to store one ASCII character.
Decode
To recognize a bar code symbology (e.g., Codabar, Code 128, Code 3 of 9,
UPC/EAN, etc.) and analyze the content of the bar code scanned.
EEPROM
Electrically Erasable Programmable Read-Only Formula™. An on-board nonvolatile Formula™ chip.
Flash Disk
Non-volatile Formula™ for storing application and configuration files.
Host
A computer that serves other mobile computers in a network, providing services
such as network control, database access, special programs, supervisory
programs, or programming languages.
Liquid Crystal Display (LCD)
A display that uses liquid crystal sealed between two glass plates. The crystals
are excited by precise electrical charges, causing them to reflect light outside
according to their bias. They use little electricity and react relatively quickly.
They require external light to reflect their information to the user.
46
Light Emitting Diode (LED)
A low power electronic light source commonly used as an indicator light. It uses
less power than an incandescent light bulb but more than a Liquid Crystal
Display (LCD).
RAM
Random Access Formula™. Data in RAM can be accessed in random order,
and quickly written and read.
RF
Radio Frequency.
RTC
Real Time Clock.
Terminal
A Datalogic portable computer product.
47
INDEX
A
Accessories; 5
Application Program; 22
Available Models; 1
B
Bluetooth® Approval; vi
Bluetooth
®
Connections; 8
C
Charging the Batteries; 33
China RoHS Pollution Control
Logos; xviii
Cleaning the Mobile Computer; 37
Connecting the Backup Battery; 32
Connection Cables; 9
RS232 Direct Connection; 9
Connections; 6
Conventions; v
D
Data Capture; 27
Laser Data Capture; 27
Datalogic Formula™ Description;
1
Deleting and Loading the
Application Program; 23
Description of the Keys using
EasyGen™; 28
Downloading Data to Host; 25
E
EasyGen™ Component Overview;
15
F
FCC Compliance; xiii
TM
Formula
Formula
Formula
Software Tools
Components; 10
TM
Software Tools
Installation; 10
TM
Software Tools
Overview; 10
G
General Safety Rules; vi
General View; xix
Glossary; 46
L
Laser Class; xi
Laser Safety; vii
LED Status; 30
M
Maintenance; 32
O
OLE for Formula™ Component
Overview; 18
P
Package Contents; 2
Patents; xvi
Power Supply; vi
R
Reading Diagram; 42
Ready-To-Use Applications
Component Overview; 18
Reference Documentation; v
References; v
Replacing the Batteries; 34
RS232 Connection; 7
S
Safety Regulations; vi
SAR Compliance; xiii
SD Card Insertion; 3
Services and Support; v
Status Indicators; 30
SW Developer’s Toolkits
WEEE Compliance; xvi
Wireless and Radio Frequencies
Warnings; xiv
49
dichiara che
declares that the
déclare que le
bescheinigt, daß das Gerät
declare que el
DL-FORMULA™ BT LASERand all its models
et tous ses modèles
und seine Modelle
y todos sus modelos
sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below
sont conformes aux spécifications des Directives de l’Union Européenne ci-dessous:
der nachstehend angeführten Direktiven des Europäischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:
Datalogic Mobile S.r.l.
Via S. Vitalino, 13
40012 - Lippo di Calderara
Bologna - Italy
e tutti i suoi modelli
1999/5/EEC R&TTE
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con la siguientes normas:
ETSI EN 301 489-17
ETSI EN 300 328 V1.7.1, OCTOBER 2006:
EN 60950-1, DECEMBER 2001:
EN 50371:2002
Lippo di Calderara, December 15th, 2008
Paola Chientaroli
V1.2.1, AUGUST 2002:
ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM
MATTERS
(ERM); ELECTROMAGNETIC COMPATIBILTY (EMC)
STANDARD FOR RADIO EQUIPMENT AND SERVICES; PART 17:
SPECIFIC CONDITIONS FOR 2,4 GHZ WIDEBAND
TRANSMISSION SYSTEMS AND
RLAN EQUIPMENT
E
LECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM
MATTERS (ERM); WIDEBAND TRANSMISSION SYSTEMS;
ATA TRANSMISSION EQUIPMENT OPERATING IN T HE 2,4GHZ
D
ISM BAND AND USING WIDE BAND MODULATION
TECHNIQUES
REQUIREMENTS UNDER ARTICLE
D
IRECTIVE
INFORMATION TECHNOLOGY EQUIPMENT - SAFETY -
P
ART 1 : GENERAL REQUIREMENTS
GENERIC STANDARD TO DEMONSTRATE THE COMPLIANCE OF
LOW POWER ELECTRONIC AND ELECTRICAL APPARATUS
WITH THE BASIC RESTRICTIONS RELATED TO HUMAN
EXPOSURE TO ELECTROMAGNETIC FIELDS
GHZ) – GENERAL PUBLIC.
; HARMONIZED EN COVERING ESSENTIAL
5 GHZ HIGH PERFORMANCE
3.2 OF THE R&TTE
(10 MHZ - 300
Quality Assurance Manager
08
dichiara che
declares that the
déclare que le
bescheinigt, daß das Gerät
declare que el
DL-FORMULA™ LASERand all its models
et tous ses modèles
und seine Modelle
y todos sus modelos
sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below
sont conformes aux spécifications des Directives de l’Union Européenne ci-dessous:
der nachstehend angeführten Direktiven des Europäischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:
89/336/EEC EMC Directive e 92/31/EEC, 93/68 /EEC emendamenti successivi
and further amendments
et ses successifs amendements
und späteren Abänderungen
y succesivas enmiendas
Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla
sicurezza dei prodotti.
On the approximation of the laws of Member States relating to electromagnetic compatibility and product
safety.
Basée sur la législation des Etats membres relative à la compatibilté électromagnétique et à la sécurité
des produits.
Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit
und Produktsicherheit entsprechen.
Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad
electromagnética y las Medidas de seguridad relativas al producto.
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con la siguientes normas:
EN 55022 ( C
EN 55024, S
A
MENDMENT A1, OCTOBER 2001
A
MENDMENT A2, JANUARY 2003
Lippo di Calderara, December 15th , 2008 Paola Chientaroli
Quality Assurance Manager
LASS B ITE ), SEPTEMBER 1998:
EPTEMBER 1998:
Datalogic Mobile S.r.l.
Via S. Vitalino, 13
40012 - Lippo di Calderara
Bologna - Italy
e tutti i suoi modelli
INFORMATION TECHNOLOGY EQUIPMENT
RADIO DISTURBANCE CHARACTERISTICS
L
IMITS AND METHODS OF MEASUREMENTS
NFORMATION TECHNOLOGY EQUIPMENT
I
I
MMUNITY CHARACTERISTICS
IMITS AND METHODS OF MEASUREMENT
L
08
www.mobile.datalogic.com
World wide Sales Network
available from: www.mobile.datalogic.com/contacts
Datalogic Mobile S.r.l.
Via S. Vitalino, 13
40012 Lippo di Calderara di Reno
Bologna - Italy
Telephone: (+39) 051-3147011
Fax: (+39) 051-3147561