Table of Contents
1Revision History ................................................................................................... 3
2.2Start Up Protocol...................................................................................................................................4
First device on the RS485 bus is named as “Master ARCB”. Master device has its specific settings which is different
than other ARCBs on the bus. All other ARCBs are named “Slave” on the bus. Master device can be connected to PC
either RS232, USB or RS485 connections. The main role of the master device is to convert communication type
RS232 (or USB) to RS485 networks. If there is an external RS485 converter, no need for master board.
2.2 Start Up Protocol
1. All ARCB boards shipped with 0 (zero) terminal ID. Change the terminal ID of the all ARCB boards by giving a
number between 1 and 255. Do this operation for each board before connecting them to the RS485 bus.
(Important: Terminal ID should be different than zero “0”)
2. Check the main data cable connecting the devices:
- Verify the SW1 switches are correctly installed at the first and last device on the RS485 bus.
SW1 jumper setting for first device:
First Node: ON (OFF if external RS485 converter is used)
Last Node: OFF (ON if external RS485 converter is used)
SW1 jumper setting for last device:
First Node: OFF
Last Node: ON (OFF if external RS485 converter is used)
- Verify the continuity of the main data cable
3. When the main data cable has been verified, power the first (master) device and connect it to the ARCS (Artista
Remote Control Service) web service running at PC (at this time, do not connect the master to the RS-485
network)
4. Verify that the ARCS web service finds the master device by using any web browser.
5. Connect the RS-485 network to the master (at this time, do not connect any slave device) and verify that ARCS
still communicates with the master device
6. Connect the first slave device to the RS-485 network and verify that ARCS still communicates with the master
device and that ARCS finds the slave device.
7. Connect the second slave device to the RS-485 network and verify that ARCS still communicates with both the
master device and the first slave device. Verify that ARCS finds the second slave device
8. Repeat the above step, adding one slave device at a time to the RS-485 network
Page 4 of 8
DATA DISPLAY GROUP
2.3 Cabling
Two main configurations are possible:
2.3.1 Cabling for system without External RS485 Converter
• All cables are same and “1-to-1”.
• Pin 1 and 2 should be twisted pair cable for all connectors
• Pin 3 and 4 should be twisted pair cable for all connectors
2.3.2 Cabling for system with External RS485 Converter
• All cables between ARCBs are same and “1-to-1”.
• Pin 1 and 2 should be twisted pair cable for all connectors
• Pin 3 and 4 should be twisted pair cable for all connectors
Page 5 of 8
DATA DISPLAY GROUP
3 RS232 and USB Setups
3.1 RS232 Setup
No setup or driver installation is required for RS232.
3.2 USB Setup
USB communication with ARCB needs driver installation to operating system. Follow these steps:
1- Download the driver packet which proper for the operating system in your PC.
https://www.silabs.com/products/mcu/Pages/USBtoUARTBridgeVCPDrivers.aspx , for Windows
2000/XP/Server 2003/Vista (v5.40) operating systems download “VCP Driver Kit” in this web-page.
2- Connect ARCB to PC with standard USB cable
3- Following message should be appear:
Click to “Cancel”.
4- Unpack and execute “CP210x_VCP_Win2K_XP_S2K3.exe” the application downloaded in first step. Following
message should be seen:
Page 6 of 8
DATA DISPLAY GROUP
5- Click “OK”. Then following message will appear, click to “Continue Anyway”:
6- Installation completed. Check the “Device Manager” to be sure of successful installation:
7- Restart the PC.
8- Do the following adjustments:
9- Finished.
Page 7 of 8
Our company network supports you worldwide with offices in Germany, Great Britain, Turkey and the USA.
For more information please contact:
Distec GmbH
Augsburger Str. 2b
82110 Germering
Germany
Phone: +49 (0)89 / 89 43 63-0
Fax: +49 (0)89 / 89 43 63-131
E-Mail: info@datadisplay-group.de
Internet: www.datadisplay-group.de
FORTEC Elektronik AG
Lechwiesenstr. 9
86899 Landsberg am Lech
Germany
Phone: +49 (0)8191 / 911 72-0
Fax: +49 (0)8191 / 217 70
E-Mail: sales@fortecag.de
Internet: www.fortecag.de
Display Technology Ltd.
5 The Oaks Business Village
Revenge Road, Lordswood
Chatham, Kent,ME5 8LF
United Kingdom
Phone: +44 (0)1634 / 67 27 55
Fax: +44 (0)1634 / 67 27 54
E-Mail: info@displaytechnology.co.uk
Internet: www.datadisplay-group.com
Apollo Display Technologies, Corp.
87 Raynor Avenue,
Unit 1Ronkonkoma,
NY 11779
United States of America
Phone: +1 631 / 580-43 60
Fax: +1 631 / 580-43 70
E-Mail: info@apollodisplays.com
Internet: www.apollodisplays.com
Sales Partner:
DATA DISPLAY BİLİŞİM TEKNOLOJİLERİ
İÇ VE DIŞ TİCARET LİMİTED ŞİRKETİ
Barbaros Mh. Ak Zambak Sk. A Blok D:143
34376 Ataşehir / Istanbul
Turkey
Phone: +90 (0)216 / 688 04 68
Fax: +90 (0)216 / 688 04 69
E-Mail: info@data-display.com.tr
Internet: www.data-display.com.tr
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.