Datadelay MDU3C-75M, MDU3C-75MC2, MDU3C-75A2, MDU3C-50, MDU3C-40M Datasheet

...
MDU3C
TRIPLE, HCMOS-INTERFACED
data
3
1
14
I1
VDD
FIXED DELAY LINE (SERIES MDU3C)
delay devices,
FEATURES PACKAGES
I1
Fits standard 14-pin DIP socket
Low profile
Auto-insertable
1
I2
3
I3
5
Input & outputs fully CMOS interfaced & buffered
GND
10 T2L fan-out capability
MDU3C-xx DIP MDU3C-xxA2 Gull-Wing MDU3C-xxB2 J-Lead MDU3C-xxM Military DIP
7
FUNCTIONAL DESCRIPTION
The MDU3C-series device is a 3-in-1 digitally buffered delay line. The signal inputs (I1-I3) are reproduced at the outputs (O1-O3), shifted in time by an amount determined by the device dash number (See Table). The delay lines function completely independently of each other.
VDD
14
O1
12
O3
10
O5
8
N/C N/C N/C
GND
PIN DESCRIPTIONS
I1-I3 Signal Inputs O1-O3 Signal Outputs VDD +5 Volts GND Ground
inc.
2
13
3
I2 I3
Military SMD MDU3C-xxMC2
12
4
11
5
10
6
9
7
8
N/C O1 N/C O2 N/C O3
SERIES SPECIFICATIONS
Minimum input pulse width: 100% of total delay
Output rise time: 8ns typical
Supply voltage: 5VDC ± 5%
Supply current: I
I
= 40µa typical
CCL
= 60ma typical
CCH
Operating temperature: to 70° C
Temp. coefficient of total delay: 300 PPM/°C
O3O2O1
100%
100% 100%
VCC GNDI1 I2 I3
Functional block diagram
DASH NUMBER SPECIFICATIONS
Part
Number
MDU3C-10 MDU3C-15 MDU3C-20 MDU3C-25 MDU3C-30 MDU3C-40 MDU3C-50 MDU3C-60 MDU3C-75 MDU3C-100
NOTE: Any dash number between 10 and 100
not shown is also available.
Delay Per
Line (ns)
10 ± 2.0 15 ± 2.0 20 ± 2.0 25 ± 2.0 30 ± 2.0 40 ± 2.0 50 ± 2.5 60 ± 3.0 75 ± 3.7
100 ± 5.0
1997 Data Delay Devices
Doc #97039 DATA DELAY DEVICES, INC. 1
12/12/97 3 Mt. Prospect Ave. Clifton, NJ 07013
MDU3C
APPLICATION NOTES
HIGH FREQUENCY RESPONSE
The MDU3C tolerances are guaranteed for input pulse widths and periods greater than those specified in the test conditions. Although the device will function properly for pulse widths as small as 100% of the total delay and periods as small as 200% of the total delay (for a symmetric input), the delays may deviate from their values at low frequency. However, for a given input condition, the deviation will be repeatable from pulse to pulse. Contact technical support at Data
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL MIN MAX UNITS NOTES
DC Supply Voltage V Input Pin Voltage V Storage Temperature T Lead Temperature T
DD
IN STRG LEAD
Delay Devices if your application requires device testing at a specific input condition.
POWER SUPPLY BYPASSING
The MDU3C relies on a stable power supply to produce repeatable delays within the stated tolerances. A 0.1uf capacitor from VDD to GND, located as close as possible to the VDD pin, is recommended. A wide VDD trace and a clean ground plane should be used.
-0.3 7.0 V
-0.3 VDD+0.3 V
-55 150 C 300 C 10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
High Level Output Voltage V Low Level Output Voltage V High Level Output Current I
Low Level Output Current I High Level Input Voltage V Low Level Input Voltage V Input Current I
(0C to 70C, 4.75V to 5.25V)
OH
OL
OH OL
IH IL
IH
3.98 4.4 V VDD = 5.0, IOH = MAX
0.15 0.26 V VDD = 5.0, IOL = MAX
3.15 V
-4.0 mA
4.0 mA
1.35 V
0.10
µA
VIH = MIN, VIL = MAX VIH = MIN, VIL = MAX
VDD = 5.0
Doc #97039 DATA DELAY DEVICES, INC. 2
12/12/97 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com