Datadelay MDU12H-50M, MDU12H-50MC3, MDU12H-50, MDU12H-4MC3, MDU12H-250M Datasheet

...
MDU12H
DUAL, ECL-INTERFACED
data
3
1
16
GND
VEE
GND
FIXED DELAY LINE (SERIES MDU12H)
delay devices, inc.
FEATURES PACKAGES
GND
1
Fits standard 16-pin DIP socket
Auto-insertable
I1
VEE
5
I2
6
8
Input & outputs fully 10KH-ECL interfaced & buffered
MDU12H-xx DIP MDU12H-xxM Military DIP
FUNCTIONAL DESCRIPTION
The MDU12H-series device is a 2-in-1 digitally buffered delay line. The signal inputs (I1-I2) are reproduced at the outputs (O1-O2), shifted in time by an amount determined by the device dash number (See Table). The delay lines function completely independently of each other.
GND
16
O1
15
O2
14
N/C N/C N/C
N/C
MDU12H-xxC3 SMD MDU12H-xxMC3 Mil SMD
PIN DESCRIPTIONS
I1-I2 Signal Inputs O1-O2 Signal Outputs VEE -5 Volts GND Ground
2
15 3 4 5
I1
6
I2
7 8
O1
14
O2
13
N/C
12
N/C
11
N/C
10
N/C
9
N/C
SERIES SPECIFICATIONS
Minimum input pulse width: 50% of total delay
Output rise time: 2ns typical
Supply voltage: -5VDC ± 5%
Power dissipation: 200mw typical (no load)
Operating temperature: -30° to 85° C
Temp. coefficient of total delay: 100 PPM/°C
O2O1
100%
100%
VCC GNDI1 I2
Functional block diagram
1997 Data Delay Devices
DASH NUMBER SPECIFICATIONS
Part
Number
MDU12H-3 MDU12H-4 MDU12H-5 MDU12H-10 MDU12H-15 MDU12H-20 MDU12H-25 MDU12H-30 MDU12H-35 MDU12H-40 MDU12H-45 MDU12H-50 MDU12H-60 MDU12H-75 MDU12H-100 MDU12H-125 MDU12H-150 MDU12H-200 MDU12H-250
* Total delay is referenced to first tap output Input to first tap = 1.5ns ±± 1ns
NOTE: Any dash number between 3 and 50
not shown is also available.
Delay Per
Line (ns)
3 ± 1.0 4 ± 1.0
5 ± 1.0 10 ± 1.0 15 ± 1.0 20 ± 1.0 25 ± 2.0 30 ± 2.0 35 ± 2.0 40 ± 2.0 45 ± 2.2 50 ± 2.5 60 ± 3.0 75 ± 3.7
100 ± 5.0 125 ± 6.2
150 ± 7.5 200 ± 10.0 250 ± 12.5
Doc #97038 DATA DELAY DEVICES, INC. 1
12/12/97 3 Mt. Prospect Ave. Clifton, NJ 07013
MDU12H
APPLICATION NOTES
HIGH FREQUENCY RESPONSE
The MDU12H tolerances are guaranteed for input pulse widths and periods greater than those specified in the test conditions. Although the device will function properly for pulse widths as small as 50% of the total delay and periods as small as 100% of the total delay (for a symmetric input), the delays may deviate from their values at low frequency. However, for a given input condition, the deviation will be repeatable from pulse to pulse. Contact technical support at Data
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL MIN MAX UNITS NOTES
DC Supply Voltage V Input Pin Voltage V Storage Temperature T Lead Temperature T
EE
IN STRG LEAD
Delay Devices if your application requires device testing at a specific input condition.
POWER SUPPLY BYPASSING
The MDU12H relies on a stable power supply to produce repeatable delays within the stated tolerances. A 0.1uf capacitor from VEE to GND, located as close as possible to the VEE pin, is recommended. A wide VEE trace and a clean ground plane should be used.
-7.0 0.3 V
VEE - 0.3 0.3 V
-55 150 C 300 C 10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
High Level Output Voltage V Low Level Output Voltage V High Level Input Voltage V Low Level Input Voltage V High Level Input Current I Low Level Input Current I
OH OL
IH
IL IH IL
(0C to 75C)
-1.020 -0.735 V
-1.950 -1.600 V
-1.070 V
-1.480 V 475
0.5
µA µA
VIH = MAX,50 to -2V VIL = MIN, 50 to -2V
VIH = MAX VIL = MIN
Doc #97038 DATA DELAY DEVICES, INC. 2
12/12/97 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
Loading...