1Terms of Use ............................................................................................................................................... 3
1.5 Certifications and Marks ................................................................................................................................. 3
1.6 Safety Notices and Warnings .......................................................................................................................... 4
2.1 What Shipped? ............................................................................................................................................... 6
2.4 Front — Any-to-Any Ports .............................................................................................................................. 7
2.5 Front — Power & Status Indicators ............................................................................................................... 8
2.6 Front — Display and Buttons ......................................................................................................................... 8
2.7 Rear — Power Module ................................................................................................................................... 9
4.2 Connecting via Telnet/SSH ............................................................................................................................ 14
4.3 Web Browser ................................................................................................................................................. 17
5.1 Media Conversion ......................................................................................................................................... 19
6.Customer Service ..................................................................................................................................... 26
The following terms and conditions relate to the use of this document. Please note that Datacom
Systems Inc. reserves the right, at its entire discretion, to change, modify, add, or remove portions of
these Terms of Use at any time. Please read the Terms of Use carefully as your use of this document
is subject to the Terms of Use stipulated herein.
Notice to All Users: By using Datacom Systems, Inc. products, you agree to the terms set forth. No
licenses, express or implied, are granted with respect to the technology described and Datacom
Systems, Inc. retains all rights with respect to the technology described herein. If applicable, you
may return the product to the place of purchase for a full refund.
1.3 Proprietary Notice
This document contains proprietary information about the VS-1012-F, VS-1112-F, VS-1212-F, VS1024-F, VS-1124-F, and VS-1224-F Data Access Switches Command Line Interface (CLI) and is
not to be disclosed or used except as authorized by written contract with Datacom Systems, Inc.
1.4 Trademark Attribution
Access Your Network™ , DURAstream™ , SINGLEstream™ , and VERSAstream™ , are
trademarks of Datacom Systems, Inc. All other registered and unregistered trademarks are the sole
property of their respective owners. All specifications may be changed without notice.
1.5 Certifications and Marks
For information regarding certifications and marks, please refer to the product info section of our
These explanatory labels are included in this information for the user in accordance
with the requirements of IEC 60825.1.
WARNING
A class 1 laser is safe under all conditions of normal use. Invisible laser radiation may
be emitted from optical port openings when no fiber cable is connected, avoid exposure
to laser radiation and do not stare into open optical ports.
IMPORTANT: Rack Mount Instructions are included here to call the attention of installation technicians to
pertinent safety and warning issues prior to the installation of the product as follows:
A.
Elevated Operating Ambient — If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient. Therefore, consideration should
be given to installing the equipment in an environment compatible with the maximum ambient temperature
specified.
B.
Reduced Air Flow — Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
C.
Mechanical Loading — Mounting of the equipment in the rack should be such that a hazardous condition is
not achieved due to uneven mechanical loading.
D.
Circuit Overloading — Consideration should be given to the connection of the equipment to the supply
circuit and the effect that overloading of the circuits might have on over-current protection and supply
wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this
concern.
E.
E.
Reliable Earthing — Reliable earthing of rack-mounted equipment should be maintained. Particular
Reliable Earthing — Reliable earthing of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the branch circuit (e.g.
attention should be given to supply connections other than direct connections to the branch circuit (e.g.
use of power strips).
use of power strips).
F. N
o user servicable parts inside. Do not open the product. Product must be returned to factory for repair.
: When used with any
Class 1 laser and LED products. (SFP+/SFP transceivers)
This FASTstart Guide for the VS-10XX-F, VS-11XX-F, and the VS-12XX-F Network Packet
Brokers is intended to provide you with information needed to get your Network Packet Broker up
and running. Additional support, documentation and help can be found on the Datacom Systems
website: http://www.datacomsystems.com
Network Packet Brokers increase network visibility and leverages your investment in network
analyzers, probes, and security equipment. The Network Packet Broker filtering and load balancing
functionality allows you to "lighten the load" to your network analyzers, probes, and security
equipment by allowing you to filter only the data you want to monitor and distribute it among the
tools evenly. Greater selectivity and visibility accelerates problem resolution, reduces downtime and
increases enterprise productivity.
Like all Datacom Systems Data Access Products, the VERSAstream Network Packet Brokers are
compatible with all vendor hardware and can be controlled by web browser based software or
Command Line Interface (CLI), which will allow you to control all of your Network Packet Broker
products through a single interface regardless of what network appliances you choose to deploy.
Datacom Systems supports the following small form-factor pluggable (SFP) transceivers and
enhanced small form-factor pluggable (SFP+) transceivers:
2.4 Front — Any-to-Any Ports
When receiving traffic, the Any-to-Any ports on the front of the VERSAstream can be connected to
Tap outputs, SPAN ports, and mirror ports.
When transmitting traffic, the Any-to-Any ports can be connected to devices such as security
probes, intrusion detection systems (IDS), and packet analyzers.
On the front panel, the power status of the device can be determined through three indicators labeled
“POWER 1”, “POWER 2”, and “STATUS”.
12-Port Versions
24-Port Versions
The LEDs located next to each power label will illuminate green when a power supply is
connected and switched ON.
When the power indicators illuminate red, it indicates that there either is not a power supply
connected, or it is not switched ON.
Although only one power source is required to power the VERSAstream, use of a second
independent power source is strongly recommended to assure uninterrupted monitoring.
The “STATUS” LED indicator is orange during the boot-up cycle and turns green upon a
successful boot sequence indicating the VERSAstream is operational.
NOTE: The “STATUS” LED indicator indicates the device is ready several seconds before it is
ready to respond to Command Line Interface (CLI) commands.
2.6 Front — Display and Buttons
The display shows Serial and Management Port status. The Selectable Buttons are for future
use.
Each VERSAstream has two power modules on the back. These are for dual redundant power
supplies and should be connected to two separate circuits to ensure uninterrupted monitoring. Each
power module has an AC power socket, an AC power switch, and two LED indicators labeled “AC”
and “DC”. These LED indicators function in unison with the “POWER 1”, and “POWER 2”
indicators on the front of the device.
The LEDs located next to the “AC” and“DC” labels will illuminate green when a power supply is
connected and switched ON.
If either LED is illuminated red, it indicates a defective power source. Immediate investigation is
recommended to insure redundant power integrity.
2.8 Rear — Management Module
The SERIAL 1 connector port is a shielded DB9
Female. This port can be connected to the COM
port of any compatible network tool or PC in
order to access the Command Line Interface for
device configuration.
The SERIAL 2 connector port is reserved for future use.
The MANAGEMENT connector port is a shielded RJ45 and is cabled to the network.
The Media Access Control (MAC) address identifier and certification compliance identifiers are
provided on this rear label.