Datacom Systems 1000BT-AT-SX User Manual

Warranty
Datacom Systems, Inc. (DSI) warrants that the hardware which it supplies will be free
from significant defects in materials and workmanship for a period of two years from
the date of delivery (Warranty Period), under normal use and conditions. In the event
of any such defect, you can return an item of defective hardware, freight prepaid, to
DSI during the Warranty Period, and DSI will repair or replace the defective equipment
and return it to you, freight prepaid. If DSI determines that the equipment is not defec-
deficiency resulting from accidents, misuse, modifications, power disturbances
(including use of a power supply not specified by DSI), or various other forms of dis-
aster, e.g., earthquakes, floods, etc.
PLEASE DO NOT ATTEMPT TO RETURN ANY ITEM PRIOR TO RECEIVING
ARETURN MATERIALAUTHORIZATION (RMA) NUMBER FROM DATACOM
CUSTOMER SERVICE AT (315) 463-9541
Limitation On Liability
The warranties set forth above are exclusive and in lieu of all other warranties.
Datacom Systems, Inc. (DSI) makes no other warranties, expressed or implied, and
DSI expressly disclaims all other warranties, including but not limited to implied war-
ranties of merchantability and fitness for a particular purpose. Moreover, the provisions
set forth above state DSI’s entire responsibility and your sole and exclusive remedy
with respect to any breach of warranty or contract.
No liability for consequential damages. Under no circumstances and under no theory
of Liability shall DSI be liable for costs of procurement of substitute products or serv-
ices, lost profits, lost savings, loss of information or data, or any other special, indirect,
consequential or incidental damages, arising in any way out of the sale of, use of, or
inability to use, any DSI product or service, even if DSI has been advised of the possi-
bility of such damages.
DATACOMsystems
®
1000BT-AT-SX Full-Duplex Tap
Quick Installation Guide
Copyright
Copyright ©2003 by Datacom Systems, Inc. All rights reserved. Printed in the United States of America. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, elec­tronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Datacom Systems, Inc. To obtain this permission, write to the attention of the Datacom Systems legal department at 9 Adler Drive, East Syracuse, New York 13057-1290, or call 315-463-9541.
Customer Service
This Quick Installation Guide was written to help you get to know your new 10/100-AT quickly and easily. We would welcome any comments or sugges­tions you may have regarding this Quick Installation Guide. Please send your remarks and recommendations via mail, telephone, facsimile, or Internet E­mail.
Datacom Customer Service personnel are available from 8
AM to 5:30 PM
Eastern time, weekdays. Customer Service is available via telephone, facsimile, and Internet E-mail. Outside of support hours, please leave a voice message and our Customer Service Staff will return your call as soon as possible.
Mail: Datacom Systems, Inc.
Customer Service 9 Adler Drive East Syracuse, NY 13057-1290
Tel: (315) 463-9541 FAX: (315) 463-9557 E-mail: support@datacomsystems.com
World Wide Web
You can obtain additional information about Datacom Systems, Inc. and its products and services from the World Wide Web at http://www.datacomsys-
tems.com.
February 2004
Part Number: 541-0078-A.00
Empowering Network Professionals
DATACOM
SYSTEMS INC
DATACOMsystems®Family of Products
11/10/2003
OPTICALswitch
MODEL PORTS TOPOLOGY CONNECTIVITY
1X8SP-OM (S) 8 100FX, OC3, OC12, Gigabit Dual SC 1X8SY-OM (S) 8 100FX, OC3, OC12, Gigabit Dual SC
LANswitch
ATM In-Line
MODEL PORTS TOPOLOGY CONNECTIVITY
2X8SY-ATM-M (S) 2x8 ATM, OC3-OC12 Dual SC
Ethernet/Token Ring
MODEL PORTS TOPOLOGY CONNECTIVITY
2X16FD-SY 2x16 10/100 BaseT RJ45 MX8100E/Tsl 2x8 10/100 BaseT or Token RJ45 MX16100E/Tsl 2x16 10/100 BaseT or Token RJ45
Fiber Custom
MODEL PORTS TOPOLOGY CONNECTIVITY
4XSPSY-CM 4 Gigabit Dual SC 4X8SY-SX 4X8 Gigabit Dual SC 4X8SP4-SX 4X8 Gigabit Dual SC 4X16SP-SX 4X16 Gigabit Dual SC
Gigabit In-Line
MODEL PORTS TOPOLOGY CONNECTIVITY
1X8SY-SX (LX) 1x8 Gigabit Dual SC 2X8SY-SX (LX) 2x8 Gigabit Dual SC
Gigabit SPAN
MODEL PORTS TOPOLOGY CONNECTIVITY
1X8SP-SX (LX) 1x8 Gigabit Dual SC 2X4SY-SX (LX) 2x4 Gigabit Dual SC 2X8SY-SX (LX) 2x8 Gigabit Dual SC
Gigabit SPAN + In-Line
MODEL PORTS TOPOLOGY CONNECTIVITY
2X8SP4-SX (LX) 2x8 Gigabit Dual SC
Receive Only
MODEL PORTS TOPOLOGY CONNECTIVITY
2X8RX-SX 2x8 Gigabit Dual SC
ACCESSORY
Software
MANAgents — Multiple Agent Controlling Console Software
Support
M3415A — V.35 Connectivity Panel RMC-3 — 1U Rack Panel for 3 Small Form DSI Products SCS — Switch Control Server
TAP
Ethernet/Token Ring
MODEL PORTS TOPOLOGY CONNECTIVITY
10/100-AT 1 10/100 BaseT RJ45 1000BT-AT 1 1000 BaseT RJ45
Fiber
MODEL PORTS TOPOLOGY CONNECTIVITY
F50/50/62-M 1 100FX, OC3, OC12, Gigabit Dual SC F50/50/50-M 1 100FX, OC3, OC12, Gigabit Dual SC F50/50/9-S 1 OC3, OC12, Gigabit Dual SC
PERMAlink™Tray
MODEL PORTS TOPOLOGY CONNECTIVITY
8SY-M/62 8 100FX, OC3, OC12, Gigabit Dual SC 8SY-M/50 8 100FX, OC3, OC12, Gigabit Dual SC 8SY-S/9 8 OC3, OC12, Gigabit Dual SC
VERSAtap
MODEL PORTS TOPOLOGY CONNECTIVITY
4SY-SX+4C 4 Gigabit Dual SC & LC
WAN
MODEL PORTS TOPOLOGY CONNECTIVITY
DS3AT1 (4) (8) 1 (4) (8) DS3 BNC DS3-AT 1 DS3 BNC DS3/E3-PT 1 DS3/E3 BNC E3-AT 1 E3 BNC T1/E1-PT 1 T1/E1 RJ48
VERSAlink
MODEL PORTS TOPOLOGY CONNECTIVITY
1X4SY-SX+2C 1X4 Gigabit Dual SC & LC 1X8SY-SX+2C 1X8 Gigabit Dual SC & LC 2X4SY-SX+2C 2X4 Gigabit Dual SC & LC 2X8SY-SX+2C 2X8 Gigabit Dual SC & LC
WAN
MODEL PORTS TOPOLOGY CONNECTIVITY
W2358Dsl 2X8 WAN DB15 WX8T1/E1sl 2X8 T1/E1 RJ48 WX16T1/E1sl 2X16 T1/E1 RJ48 D28100BTSL 1x8 • 10/100BaseT and RJ48 •
1x8 WAN DB15
DS3-8Csl 2X8 DS3 BNC 2X4SY-DS3/E3 2X4 DS3/E3 BNC
Compliance Testing
CAUTION: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Certifications
This equipment has been tested and found to meet the radiated and conducted emission limits for a Class B product of EN 55022 to the EMC Directive 89/336/EEC requirements.
This equipment has been tested and found to meet the immunity levels for
Class 1 tested to level 2 for EN 6100-4-2, tested to level 3 for EN 61000­4-3, tested to level 2 for EN 61000-4-4, and tested to level 3 for EN 61000- 4-5 to the EN 50082-1 requirements and meets the Class A requirements for EN 61000-3-2 and EN 61000-3-3.
This equipment has completed the Product Safety Review and found to meet the Low Voltage Directive 72/23/EEC (1993) requirements.
Empowering Network Professionals
DATACOM
SYSTEMS INC
DATACOMsystems®1000BT-AT-SX Quick Installation Guide
11
11
What’s in the Package
1000BT-AT-SX Full-Duplex Tap
Instructions
22
22
Introduction
The 1000BT-AT-SX is a single-port full-duplex device that provides an easy method to rapidly and effectively deploy your analysis tools to monitor 1000 BaseT traffic between your network devices. Typically the tap is installed on a critical 1000 BaseT link in the net­work where monitoring and analysis capabilities are important.
1000BT-AT-SX features and benefits:
• 1000 BaseT compatible
• Full duplex monitoring
• Power fault tolerant
• Standard RJ45 and SX connectors
33
33
1000BT-AT-SX Specifications
Specification
Channel
One directional 1000 BaseT Ethernet
Feature
Cable Type CAT 5E and Mulimode fiber
Port Connectivity
NETWORK A NETWORK B TAP A TAP B
RJ45 RJ45 SX SX
Distance Limit
90 meter maximum length between net­work end-points. Tap typically 1 meter.
Power Requirements External power supply 5 VDC, 1 A
5555
Functional Operation
Refer to FIGURE 1 for a diagram of the functional operation of the 1000BT-AT-SX.
66
66
Connecting a 1000BT-AT-SX to the the Network
FIGURE 1 — 1000BT-AT-SX Functional Diagram
FIGURE 2 — 1000BT-AT-SX Simple Connectivity Diagram
To connect the 1000BT-AT-SX into the network, refer to FIGURE 2 and follow these steps:
IMPORTANT:
The maximum length of 90 meters must not be
exceeded between end-points.
1. Connect the Power Supply barrel connector into the POWER port
of the 1000BT-AT-SX and then plug the Power Supply into the external power source wall receptacle. The POWER LED to the right of the RJ connectors illuminates indicating power is on.
2. Connect one of the network device cables to the 1000BT-AT-SX
RJ45 port NETWORK A connector. The NET-A LINK LED illumi­nates indicating link has been established between the NETWORK A connector and NETWORK A device.
3. Connect the other network device cable to the 1000BT-AT-SX
RJ45 port NETWORK B connector. The NET-B LINK LED illumi­nates indicating link has been established between the NETWORK B connector and NETWORK B device.
The Rx-A, Tx-A, Rx-B, and Tx-B LEDs illuminate as data is passed back and forth between the NETWORK A and NETWORK B device.
4. Connect one tap cable from the 1000BT-AT-SX RJ45 port TAP A
connector into one port of the Network Analysis Tool interface card. The TAP-A LINK LED illuminates indicating link has been established between the TAP A connector and Network Analysis Tool interface card.
5. Connect the other tap cable from the 1000BT-AT-SX RJ45 port
TAP B connector into the other port of the Network Analysis Tool interface card. The TAP-B LINK LED illuminates indicating link has been established between the TAP B connector and Network Analysis Tool interface card.
Operating Temperature
0Oto 40OC (32Oto 104OF)
Storage Temperature
-30Oto 65OC (-22Oto 149OF)
Humidity
Less than 95OC non-condensing
Dimensions
1.10" (H) x 5.75" (W) x 5.75" (D) (includes rack mount bracket)
28 mm (H) x 146 mm (W) x 146 mm (D)
Weight
Unit - 12 ounces; Shipping - 2 pounds
Power Supply
AC Power Cable
44
44
Installing a 1000BT-AT-SX in an Equipment Rack
Prior to putting the 1000BT-AT-SX in a standard 19-inch rack you may want to contact your 1000BT-AT-SX representative to discuss an optional rack panel or ...
ANSI/EIA-310-D-1992 Mounting Flange Dimensional Requirements
Dimensions are in millimeters
Three devices shown mounted in optional rack panel
In any case, a couple of equipment considerations should be noted:
• Do you have universal or wide spacing flanges?
• The 1000BT-AT-SX occupies 1 unit of space when properly fastened in a universal flange. The 1000BT-AT-SX occupies part of 2 adjoining units of space when improperly fastened in a wide spacing hole of a universal or wide-space flange.
Single device shown with rack mount bracket
1000BT-AT-SX device with thumbscrew bracket to mount in RMC-3 panel
optional single mount rack bracket.
Loading...