Step 1 Installation of Back Panel
Place plate with telephone 110 IDC on wall location and trace openings
for cut outs on wall. Remove plate and make cut outs for cables. Pull telephone and televisioncables through cut outs in the wall.
Pull cables through back of plate 70-0050 module plate and secure plate
Step 2 Telephone
Install the wire from the telephone demarcation point to the 110 IDC
marked from Telco.
Install the twisted pair cables from each location in the house to the
remaining 110 IDC connectors. Match the color-coding of the wires to the colors on the 110 IDC connectors. Incoming phone service can betested using the test port.
All cables should be punched down, using an industry standard punch-
down tool, to the 110 IDC connectors following the T568A wiring configuration as shown below.
Line 1 is Blue, Line 2 is Orange, Line3 is Green and Line 4 is Brown.
White / Bl ue Blue
White / Orange Orange
White / Green
Green White / Brown Brown
Step 3 Video
Attach a male F-connector onto the cable TV service or satellite service
incoming cable. Screw the incoming cable with F-connector to the connector marked input.
Using F-connectors, terminate all coaxial leads that have been pulled
through the cut outs in the wall to the remaining connectors on the splitter.
Secure the cover of the 70-0050 module to the back panel and tighten
screws located at the bottom of the back plate of the module.
INSTRUCTIONS ARE CONTINUED ON THE BACK SIDE OF THIS PAGE
2/25/08 Rev. 1
Instruction / Installation Sheet
ETL LISTED
DataComm Electronics Home Command Center II 70-0050
CAUTION
Never install telephone wiring during lighting storms.Never install telephone jacks in wet locations unless the jack is
specifically designed for wet locations.
Never touch un-insulated wires or terminals unless the telephone
line has been disconnected at the network interface.
Use caution when installing or modifying telephone lines.
IMPORTANT INSTRUCTIONS
Read and understand all instructions.Follow all warnings and instructions marked on the product.
Do not use this product near water, for example neara bath tub,
wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool.
SAVE THESE INSTRUCTIONS.
ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT
CONFORMS TO
UL STD 1863
ANSI/UL STD 60950-1
3026001
CAN/CSA STD C22.2 NO 60950-1
CERTIFIED TO