Instruction / Installation Sheet
DataComm Electronics 8-Port Passive Data Module 70-0030
Installation
Align the mounting pins with holes in the back of the HCC panel and lock
module into place.
Pull the Cat 5 or higher rated cables into the HCC panel from one of the
side knockouts.
InstallCat 5 or higher rated cables from each location in the house to the
8-port passive data module. Match the color-coding of the wires to the
colors on the 110 IDC connectors.
The wires should be punched down, using an industry standard punch-
down tool, to the 110 IDC connectors following the T568A wiring
configuration as shown below.
CAUTION
Never install telephone wiring during lighting storms.
Never install telephone jacks in wet locations unless the jack is
specifically designed for wet locations.
Never touch un-insulated wires or terminals unless the telephone
line has been disconnected at the network interface.
Use caution when installing or modifying telephone lines.
IMPORTANT INSTRUCTIONS
Read and understand all instructions.
Follow all warning and instructions marked on the product.
Do not use this product near water, for example near bath tub, wash
bowl, kitchen sink, or laundry tub, in a wet basement, or near a
swimming pool.
SAVE THESE INSTRUCTIONS.
White / Blue
Blue
White / Orange
Orange
White / Green
Green
White / Brown
Brown
ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT
CONFORMS TO
UL STD 1863
ANSI/UL STD 60950-1
3026001
CAN/CSA STD C22.2 NO 60950-1
CERTIFIED TO
10/5/07 Rev. 1