Step 1
Pull the telephone wires into the HCC panel fromtop or one of the side
knockouts.
Using the black push pins, install the 70-0026 RJ45 telephone module in the
HCC panel. Install the cable from the telephone company demarcation point to the 110 IDC marked from Telco. This will activate line 1, line 2, line 3 and line 4
on the RJ45 ports.
The wires should be punched down, using an industry standard punch-down tool,
to the 110 IDC connectors following the T568A wiring configuration as shown below.
Line 1 is Blue, Line 2 is Orange, Line 3 is Green and Line 4 is Brown.A RJ31X port is provided for line 1 seizure by security system.
Instruction / Installation Sheet
Step 2
Install RJ45 plugs (purchased separately – DCE part #20-5703) on all Cat 5e
wiring home runs to the HCC panel.
Be sure to wire the RJ45 plugs per the RJ45 plug instructions. Mis-wired RJ45
plugs will create a short or no dial tone.
Once all RJ45 plugs are installed on the home runs, determine which telephone
jacks in the house will be line 1. To connect line 1, insert the RJ45 plug on the Cat 5e home run into RJ45 ports labeled line 1 on the telephone module. Each
of these home runs will now be connected to line 1.
To connect line 2, use same instruction as line 1 and use line 2 labeled RJ45
ports.
To connect line 3, use same instruction as line 1 and use line 3 labeled RJ45
port.
To connect line 4, use same instruction as line 1 and use line 4 labeled RJ45
port.
White / Blue Blue
White / Orange Orange
White / Green
Green White / Brown
Brown
INSTRUCTIONS ARE CONTINUED ON THE BACK SIDE OF THIS PAGE
10/11/07 Rev. 2
Instruction / Installation Sheet
ETL LISTED
DataComm Electronics RJ45 Telephone Module 70-0026
CAUTION
Never install telephone wiring during lighting storms.Never install telephone jacks in wet locations unless the jack is specifically
designed for wet locations.
Never touch un-insulated wires or terminals unless the telephone line has
been disconnected at the network interface.
Use Caution when installing or modifying telephone lines.
IMPORTANT INSTRUCTIONS
Read and understand all instructions.Follow all warning and instructions marked on the product.
Do not use this product near water, for example near bath tub, wash bowl,
kitchen sink, or laundry tub, in a wet basement, or near a swimming pool.
SAVE THESE INSTRUCTIONS.
ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT