Instruction / Installation Sheet
DataComm Electronics 10 Port 110 Style Punch-Down Telephone Module 70-0070
Installation
Align the mounting pins with holes in the back of the HCC panel and lock module into
place.
Install the cable from the telephone company demarcation point to the 110 IDC connector
marked from Telco.
Install twisted pair cables from each location in the house to the remaining 110 IDC
connectors. Match the color-coding of the wires to the colors on the 110 IDC connectors.
The wires should be punched down, using an industry standard punch-down tool, to the
110 IDC connectors following the T568A wiring configuration as shown below.
The RJ31x port is used to install the security line.
Line 1 is Blue, Line 2 is Orange, Line 3 is Green and Line 4 is Brown.
CAUTION
Never install telephone wiring during lighting storms.
Never install telephone jacks in wet locations unless the jack is specifically
designed for wet locations.
Never touch un-insulated wires or terminals unless the telephone line has been
disconnected at the network interface.
Use caution when installing or modifying telephone lines.
IMPORTANT INSTRUCTIONS
Read and understand all instructions.
Follow all warnings and instructions marked on the product.
Do not use this product near water, for example near a bath tub, wash bowl,
kitchen sink, or laundry tub, in a wet basement, or near a swimming pool.
SAVE THESE INSTRUCTIONS.
White / Blue
Blue
White / Orange
Orange
White / Green
Green
White / Brown
Brown
ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT
CONFORMS TO
UL STD 1863
3026001
ANSI/UL STD 60950-1
CERTIFIED TO
CAN/CSA STD C22.2 NO 60950-1
2/25/08 Rev. 1