1.1 CONTENTS LIST ............................................................................................................................................. 5
2.1.5 Connecting Serial Devices ................................................................................................... 14
2.1.6 Connecting to the Network or a Host .................................................................................. 15
2.2 EASY SETUP BY CONFIGURING WEBUI ................................................................................................... 16
IOG761AM-0P001 Quick Installation Guide 2
Cellular M2M-IoT Gateway
Copyright
The contents of this publication may not be reproduced in any part or as a whole, stored,
transcribed in an information retrieval system, translated into any language, or transmitted
in any form or by any means, mechanical, magnetic, electronic, optical, photocopying,
manual, or otherwise, without the prior written permission.
Trademarks
All products, company, brand names are trademarks or registered trademarks of their
respective companies. They are used for identification purpose only. Specifications are
subject to be changed without prior notice.
IOG761AM-0P001 Quick Installation Guide 3
Cellular M2M-IoT Gateway
Chapter 1 Introduction
Congratulations on your purchase of this outstanding product: M2M-IoT Gateway. For
M2M (Machine-to-Machine) or IoT (Internet of Thing) applications, AMIT M2M-IoT
Gateway is absolutely the right choice. With built-in world-class 3G HSPA+ module, you
just need to insert SIM card from local mobile carrier to get to Internet. The redundant SIM
design provides a more reliable WAN connection for critical applications. By VPN
tunneling technology, remote sites easily become a part of Intranet, and all data are
transmitted in a secure (256-bit AES encryption) link. Through its serial port, you can
control and manage serial devices via Internet anywhere. The feature of DIDO allows
gateway to have real-time response whenever events are detected by sensors. To meet a
variety of M2M/IoT application requirements, AMIT M2M-IoT gateway products are based
on modular design. A new functional module can replace current one to support new
application in short time, such as for ZigBee or Bluetooth applications.
This IOG761 series product is loaded with luxuriant security features including VPN,
firewall, NAT, port forwarding, DHCP server and many other powerful features for complex
and demanding business and IOT (Internet-Of-Thing) applications. The redundancy
design in fallback 9-48 VDC power terminal and VRRP, and dual SIM cards make the
device as a back-up in power, data transmission, and network connection without lost.
The IOG761 series also provides the DB-9 male port for various serial communication use
through connecting the RS-485 serial device to an IP-based Ethernet LAN. These
communication protocols make user access serial devices anywhere over a local LAN or
the Internet easily.
Main Features:
Provide various and configurable WAN connection.
Support dual SIMs for the redundant wireless WAN connection.
Provide the serial and Ethernet ports for comprehensive LAN connection.
Feature with VPN and NAT firewall to have powerful security.
Support the robust remote or local management to monitor network.
Designed by solid and easy-to-mount metal body for business and IOT
environment to work with a variety M2M (Machine-to-Machine) applications.
Before installing and using this product, please read this manual carefully.
IOG761AM-0P001 Quick Installation Guide 4
Cellular M2M-IoT Gateway
Items
Description
Contents
Quantity
1
DL200
DATA LOGGER
1pcs
2
3G Antenna
2pcs
3
WiFi Antenna
2pcs
4
Power Adapter
(DC 12V/2A)
(*1)
1pcs
5
RJ45 Cable
1pcs
6
RS485 Cable
1pcs
7
Wall Mount Kits
2pcs
8
DIN-Rail Bracket
1pcs
9
USB flash drive
Mfg: SanDick
Type: SDCZ33 (8GB )
1pcs
1.1 Contents List
1 The maximum power consumption of IOG761-0P001 is 15.5W.
IOG761AM-0P001 Quick Installation Guide 5
Cellular M2M-IoT Gateway
Do not use the product in high humidity or high
temperatures.
Do not connect AC power to this device directly. This
product accepts DC power voltage from 9V to 48V.
Using a different voltage rating power source will
damage the router.
Do not open or repair the case by yourself. If the
Product is too hot, turn off the power immediately
and have it repaired at a qualified service center.
Place the product on a stable surface and avoid
using this product and all accessories outdoors.
Attention
Hardware Installation
1.2.1 WARNING
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
IOG761AM-0P001 Quick Installation Guide 6
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Cellular M2M-IoT Gateway
FCC Caution: Any changes or modifications not expressly approved by the party
responsi for compliance could void the user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
IMPORTANT NOTE:
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
Country Code selection feature to be disabled for products marketed to the
US/CANADA
IOG761AM-0P001 Quick Installation Guide 7
Cellular M2M-IoT Gateway
Network Requirements
An Ethernet RJ-45 cable or DSL modem
3G cellular service subscription
IEEE 802.11n or 802.11b/ g wireless clients
10/100 Ethernet adapter on PC
Web-based Configuration Utility
Requirements
Computer with the following:
Windows®, Macintosh, or Linux-based
operating system
An installed Ethernet adapter
Browser Requirements:
Internet Explorer 6.0 or higher
Chrome 2.0 or higher
Firefox 3.0 or higher
Safari 3.0 or higher
CD Installation Wizard Requirements
Computer with the following:
Windows® 7, Vista®, or XP with Service
Pack 2
An installed Ethernet adapter
CD-ROM drive
1.2.2 SYSTEM REQUIREMENTS
IOG761AM-0P001 Quick Installation Guide 8
Cellular M2M-IoT Gateway
Auto MDI/MDIX RJ-45 Ports
4x FE LAN to connect local devices
3G
Antenna
Reset
Button
USB Port
3G
Antenna
RS 485
Port
Console
Port
LED Indicators
SIM_B
Slot
SIM_A
Slot
1.2.3 Hardware Configuration
※Reset Button
The RESET button provides user with a quick and easy way to resort the default setting.
Press the RESET button continuously for 6 sec, and then release it. The device will
restore to factory default settings.
IOG761AM-0P001 Quick Installation Guide 9
Cellular M2M-IoT Gateway
Power Terminal Block
PWR1
GND
PWR2
GND
DI+
DI-
DO+
DO-
2.4G WiFi
Antenna
2.4G WiFi
Antenna
IOG761AM-0P001 Quick Installation Guide 10
Cellular M2M-IoT Gateway
LED Icon
Indication
LED Color
Description
Power Source 1
Green
Steady ON: Device is powered on by power
source 1
Power Source 2
(*2)
Green
Steady ON: Device is powered on by power
source 2
WLAN (WiFi)
Green
Steady ON: Wireless radio is enabled
Flash: Data packets are transferred
OFF: Wireless radio is disabled
SIM A
Green
Steady ON: SIM card A is used
SIM B
Green
Steady ON: SIM card B is used
~
LAN 1 ~ LAN 4
Green
Steady ON: Ethernet connection of LAN is
established
Flash: Data packets are transferred
High 3G Signal
Green
Steady ON: The signal strength of 3G is
strong
Low 3G Signal
Green
Steady ON: The signal strength of 3G is
weak
USB
Green
Steady ON: If USB device is attached
Serial Port
Green
Steady ON: If serial device is attached
1.2.4 LED Indication
2 If both of power source 1 and power source 2 are connected, the device will choose power source 1 first. The LED
of power source 2 will remain OFF at this condition.
IOG761AM-0P001 Quick Installation Guide 11
Cellular M2M-IoT Gateway
Step 1:
Follow red arrow to
unlock SIM socket
Step 2:
Lift up SIM holder,
and insert SIM card
Step 3:
Put back SIM holder,
and follow red arrow
to lock SIM socket
Chapter 2 Getting Started
This chapter describes how to install and configure the hardware and how to use the
set-up wizard to configure the network with the web GUI of IOG761 series.
2.1 Hardware Installation
2.1.1 Mount the Unit
The
IOG761 series can be placed on a desktop, mounted on the wall, or mounted on a
DIN-rail. It has designed with “ears” for attaching to the wall or the inside of a cabinet. The
wall-mount kits and DIN-rail bracket are not screwed on theproduct when out of factory.
Please screw the wall-mount kits and DIN-rail bracket on the product first.
2.1.2 Insert the SIM Card
WARNNING: BEFORE INSERTING OR CHANGING THE SIM CARD, PLEASE MAKE
SURE THAT POWER OF THE DEVICE IS SWITCHED OFF.
The SIM card slots are located at the bottom side of IOG761-0P001 housing in order to
protect the SIM card. You need to unscrew and remove the outer SIM card cover before
installing or removing the SIM card. Please follow the instructions to insert a SIM card.
After SIM card is well placed, screw back the outer SIM card cover.
IOG761AM-0P001 Quick Installation Guide 12
Cellular M2M-IoT Gateway
Mode
Specification
Digital
Input
Trigger Voltage (high)
Logic level 1: 3.3V~30V
Normal Voltage (low)
Logic level 0: 0V~3.0V
Digital
Output
Voltage
(Relay Mode)
Depends on external device
maximum voltage is 30V
Maximum Current
1A
PWR1
GND
PWR2
GND
DI+
DI-
DO+
DO-
2.1.3 Connecting Power
IOG761 series can be powered by connecting a power source to the terminal block. It
The
supports dual 12VDC power inputs, 30VDC digital input and output3. Following
picture is the power terminal block pin assignments. Please check carefully and connect
to the right power requirements and polarity.
There are a DC12V/2A power adapter in the package for you to easily connect DC power
adapter to this terminal block.
2.1.4 Connecting DI/DO Devices
There are a DI and a DO ports together with power terminal block. Please refer to
following specification to connect DI and DO devices.
Example of Connection Diagram
3 If both of power source 1 and power source 2 are connected, the device will choose power source 1 first. If power
outage occurred from power source 1, this device will switch to power source 2 automatically and seamlessly.
IOG761AM-0P001 Quick Installation Guide 13
Cellular M2M-IoT Gateway
Pin1
Pin2
Pin3
Pin4
Pin5
Pin6
Pin7
Pin8
Pin9
RS-232
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
RI
RS-485
DATA+
DATA-
GND
2.1.5 Connecting Serial Devices
The IOG761provides one standard serial port DB-9 male connector. Connect the serial
device to the unit DB-9 male port with the right pin assignments of RS-232/485 are shown
as below.
IOG761AM-0P001 Quick Installation Guide 14
Cellular M2M-IoT Gateway
2.1.6 Connecting to the Network or a Host
The IOG761 series
detect the transmission speed on the network and configure itself automatically. Connect
the Ethernet cable to the RJ-45 ports of the device. Plug one end of an Ethernet cable into
your computer’s network port and the other end into one of IOG761 seriesfor LAN ports
on the front panel. If you need to configure or troubleshoot the device, you may need to
connect the IOG761 series directly to the host PC. In this way, you can also use the RJ-45
Ethernet cable to connect the IOG761 series to the host PC’s Ethernet port.
provides four RJ-45 ports to connect 10/100Mbps Ethernet. It can auto
IOG761AM-0P001 Quick Installation Guide 15
Cellular M2M-IoT Gateway
Browse and Activate the Setup Wizard
Type in the IP Address (http://192.168.123.254)4
When you see the login page, type the password ‘admin’
5
and then click ‘login’ button.
After login, Select your language from the list.
2.2 Easy Setup by Configuring WEB UI
You can browse web UI to configure the device. First you need to launch the Setup
Wizard browser and then the Setup Wizard will guide you step-by-step to finish the setup
process.
Select “Wizard” for basic settings in a simple way.
Or, you can go to Basic Network / Advanced Network / Applications / System to setup
the configuration by your own selection.
4 The default LAN IP address of this gateway is 192.168.123.254. If you change it, you need to type new IP address.
5 It’s strogly recoedig you to change this login password from default value.
IOG761AM-0P001 Quick Installation Guide 16
Cellular M2M-IoT Gateway
Press“Next” to start the Setup Wizard.
Configure with the Setup Wizard
Step 1
You can change the login password of
web UI here. It’s strongly recommending
you to change this login password from
default value.
Step 2
Select Time Zone.
Step 3
You can select Auto detecting WAN
type or setup WAN type manually.
IOG761AM-0P001 Quick Installation Guide 17
Cellular M2M-IoT Gateway
Step 4
If selecting Auto Detecting WAN type, the
system will start to detect the WAN type
automatically.
The next page will show result of WAN
detection in your environment. If the result
is not exactly what you need, you can still
choose other WAN type here. You can
also change LAN IP address of this
gateway here.
Step 5
Type in Host name and ISP registered
MAC address. If you don’t have such
information, you can keep in blank and
go to next page.
Step 5-1
Wi-Fi settings. You can change SSID or
channel here, or keep them with default
settings. SSID is the name that you will
see on your PC when doing wireless
network scan.
IOG761AM-0P001 Quick Installation Guide 18
Cellular M2M-IoT Gateway
Step 5-2
Wi-Fi authentication and encryption
settings. It’s strongly recommending you
to add authentication and encryption in
your wireless network to prevent any
unknown Wi-Fi clients connecting to your
wireless network and keep transferred
data secured.
Step 6
Check the information again. If all settings
are correct, please press “Apply Settings”
button to save new settings. Then it will
take 70 seconds to take new settings
effective.
Step 7
Configuration is completed. Press “Finish”
button to close Setup Wizard and go back
to main menu.
IOG761AM-0P001 Quick Installation Guide 19
Cellular M2M-IoT Gateway
Select “Darfon” for Show All of Micro Inverter status in the monitor system.
Press “Micro Inverter” to start the Micro Inverter status view.
IOG761AM-0P001 Quick Installation Guide 20
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.