DAPAudio Xi-12B, D3442, D3443, Xi-3 User Manual

Xi-12B V1
Ordercode: D3442/D3443
Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands
ENGLISH
1
Xi-12B
Ordercode: D3442/D3443
Table of contents
Warning ............................................................................................................................................................................... 2
Safety Instructions ......................................................................................................................................................... 2
Operating Determinations .......................................................................................................................................... 3
Connection with the mains......................................................................................................................................... 4
Return Procedure .......................................................................................................................................................... 4
Claims .............................................................................................................................................................................. 4
Description of the device ................................................................................................................................................. 5
Overview ........................................................................................................................................................................ 5
Backside ......................................................................................................................................................................... 6
Installation ........................................................................................................................................................................... 6
Set Up and Operation ....................................................................................................................................................... 7
System Setup Example (8 x Xi-3 and 2 x Xi-12B) ...................................................................................................... 7
Connection Cables ........................................................................................................................................................... 8
Recommended Speaker Cables............................................................................................................................... 9
Maintenance ...................................................................................................................................................................... 9
Troubleshooting ................................................................................................................................................................. 9
Product Specifications ...................................................................................................................................................... 9
Dimensions ........................................................................................................................................................................10
2
Xi-12B
Ordercode: D3442/D3443
Warning
Unpacking Instructions
Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure that all parts are present, and have been received in good condition. Notify the dealer immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
Your shipment includes:
2 x DAP Audio Xi-12B
User manual
Safety Instructions
Every person involved with the installation, operation and maintenance of this system has to:
be qualified
follow the instructions of this manual
Before you initial start-up, please make sure that there is no damage caused by transportation. Should there be any, consult your dealer and do not use the system. To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual. Please consider that damages caused by manual modifications to the system are not subject to warranty. This system contains no user-serviceable parts. Refer servicing to qualified technicians only.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the system.
Always disconnect power from the mains, when system is not used. Only handle the power cord by
the plug. Never pull out the plug by tugging the power cord.
Always operate the unit with the AC ground wire connected to the electrical system ground.
3
Xi-12B
Ordercode: D3442/D3443
Avoid flames and do not put close to flammable liquids or gases.
Avoid ground loops! Always be sure to connect the power amps and the mixing console to the
same electrical circuit to ensure the same phase!
Avoid installing your equipment very near radio or TV sets, mobile phones, etc., as these can cause
RF (radio frequency) interference.
Before changing your grounds around, always turn your amplifiers down.
Do not connect this device to a dimmer pack.
Do not drive the inputs with a signal level higher than required to drive the equipment to full output.
Do not open this device. Risk: hazardous radiation exposure.
Do not switch the system on and off in short intervals, as this would reduce the system’s life.
Extreme frequency boosts in connection with a high input signal level may lead to overdriving your
equipment. Should this occur, it is necessary to reduce the input signal level by using the INPUT control.
If device is dropped or struck, disconnect mains power supply immediately. Have a qualified
engineer inspect for safety before operating.
If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not
switch it on immediately. The arising condensation water might damage your system. Leave the system switched off until it has reached room temperature.
Make sure that the available voltage is not higher than stated on the rear panel.
Make sure that the power cord is never crimped or damaged. Check the device and the power
cord from time to time.
Make sure that the signals into the mixer are balanced, otherwise hum could be created.
Make sure that there is sufficient room on all sides of the system for air circulation.
Make sure you do not use the wrong kind of cables or defective cables.
Make sure you use DI boxes to balance unbalanced signals; All incoming signals should be clear.
Never let the power cord come into contact with other cables! Handle the power cord and all
connections with the mains with particular caution!
Never remove warning or informative labels from the unit.
Never use anything to cover the ground contact.
Only use device indoors, avoid contact with water or other liquids.
Please turn off the power switch, when changing the power cord or signal cable, or select the input
mode switch.
Prevent distortion! Make sure that all components connected to the Xi-12B have sufficient power
ratings. Otherwise distortion will be generated because the components are operated at their limits.
Repairs, servicing and electric connection must be carried out by a qualified technician.
The best way (even if not always feasible) to avoid ground loops is to connect the electric ground of
all the equipment to a single central point (“star” system). In this case, the central point can be the
mixer.
To avoid or solve hum and buzzing troubles, try different combinations of lifting grounds on units that
are supplied with ground lift switches or make sure all chassis are connected to earth ground, either through the A.C. power cord ground or by the front panel rack mount screws.
To emphasize a frequency range, you do not necessarily have to move its respective slider upwards;
instead, try lowering surrounding frequency ranges. This way, you avoid causing the next piece of equipment in your sound path to overdrive. You also preserve valuable dynamic reserve
(“headroom”).
When connecting the other parts of your sound system, watch out for the so-called “ground loops”.
WARRANTY: Till one year after date of purchase.
Operating Determinations
If this system is operated in any other way, than the one described in this manual, the product may
suffer damages and the warranty becomes void.
Any other operation may lead to dangers like short-circuit, burns, electric shock, etc.
You endanger your own safety and the safety of others!
Improper installation can cause serious damage to people and property!
4
Xi-12B
Ordercode: D3442/D3443
Connection with the mains
Connect the device to the mains with the power-plug. Always pay attention, that the right color cable is connected to the right place.
International
EU Cable
UK Cable
US Cable
Pin
L
BROWN
RED
YELLOW/COPPER
PHASE
N
BLUE
BLACK
SILVER
NEUTRAL
YELLOW/GREEN
GREEN
GREEN
PROTECTIVE GROUND
Make sure that the device is always connected properly to the earth!
Improper installation can cause serious damage to people and property!
Return Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. Call Highlite 0031-455667723 or mail aftersales@highlite.nl and request an RMA prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.
Note: If you are given an RMA number, please include the following information on a piece of paper inside the box:
01) Your name
02) Your address
03) Your phone number
04) A brief description of the symptoms
Claims
The client has the obligation to check the delivered goods immediately upon delivery for any short­comings and/or visible defects, or perform this check after our announcement that the goods are at their disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Transportation damage has to be reported to us within one day after receipt of the delivery. Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless otherwise agreed in writing. Complaints against us must be made known in writing or by fax within 10 working days after receip t of the invoice. After this period complaints will not be handled anymore. Complaints will only then be considered if the client has so far complied with all parts of the agreement, regardless of the agreement of which the obligation is resulting.
5
Xi-12B
Ordercode: D3442/D3443
Description of the device
Features
The Xi-12B is a front-loaded 12" vented subwoofer with the extra low grunt, needed for maximizing your sound experience. Combined with the Xi-3 cabinets (D3432/D3433), this little subwoofer will complete the already versatile range for any application.
Impedance: 4 Ω
Continuous power: 300W
Program power: 600W
Peak power: 900W
Components: 12 woofer with 2,5” VC
Frequency response (processed): 42-150 Hz
Frequency response (flat, -10dB): 42-2800 Hz
Recommended HPF: 42Hz, BW-24
Recommended LPF: 150Hz, LR-24
Sensitivity (full space): 99dB/W/m
Peak SPL @1m: 125dB
Normal dispersion (HxV): 360° x 180°
Connectors: Speakon IN/THRU, 4-pin terminal block IN/OUT
Housing: Birch Plywood, resistant black finish
Color: Black (D3442), White (D3443)
Dimensions: 540 x 350 x 513 mm (LxWxH)
Weight: 18,3 kg
Overview
Fig. 01
6
Xi-12B
Ordercode: D3442/D3443
Backside
Fig. 02
01) Speakon connector IN
Connect to an amplifier.
02) 4-pin terminal block IN/OUT
This input/output is connected in parallel with the Speakon input (01) and can be used for powering another speaker.
03) Speakon connector THRU
This output is connected in parallel with the Speakon input (01) and can be used for powering another speaker.
Fig. 03
Installation
Remove all packing materials from the Xi-12B. Check if all foam and plastic padding is removed. Connect all cables.
Do not supply power before the whole system is set up and connected properly. Always disconnect from electric mains power supply before cleaning or servicing. Damages caused by non-observance are not subject to warranty.
7
Xi-12B
Ordercode: D3442/D3443
Set Up and Operation
Follow the directions below, as they pertain to your preferred operation mode.
System Setup Example (8 x Xi-3 and 2 x Xi-12B)
Make your initial connections with all the equipment powered off and ensure that all the main volume controls are turned completely to the minimum. Follow the steps below.
01) Connect the outputs on your mixer with the inputs on your digital crossover.
02) Connect the high-pass outputs on your digital crossover with the dedicated inputs on your amplifier.
03) Connect the low-pass outputs on your digital crossover with the dedicated inputs on your amplifier.
04) Use speaker cables to connect the corresponding high-pass outputs (160Hz) on your amplifier with
the input sockets on your Xi-3 satellite cabinets (D3432/D3433).
05) Use speaker cables to connect the corresponding low-pass outputs (160Hz) on your amplifier with the
input sockets on your Xi-12B subwoofers (D3442/D3443).
06) Turn on your mixer first, then the amplifier.
07) After using your equipment, turn off your amplifier first, then the mixer.
Fig. 04
8
Xi-12B
Ordercode: D3442/D3443
Connection Cables
Take care of your cables, always holding them by the connectors and avoiding knots and twists when coiling them: This gives the advantage of increasing their life and reliability. Periodically check your cables. A great number of problems (faulty contacts, ground hum, discharges, etc.) are caused entirely by using unsuitable or faulty cables.
Headphone
Unbalanced
Balanced
For these applications the unit provides 1/4" TRS and XLR connectors to easily interface with most professional audio devices. Follow the configuration examples below for your particular connection.
Unbalanced
Balanced
9
Xi-12B
Ordercode: D3442/D3443
Recommended Speaker Cables
FS01150 – FS01 jack mono > jack mono, 2 x 1,5mm2 (1,5 m) FS013 – FS01 jack mono > jack mono, 2 x 1,5mm2 (3 m) FS016 – FS01 jack mono > jack mono, 2 x 1,5mm2 (6 m) FS0110 – FS01 jack mono > jack mono, 2 x 1,5mm2 (10 m) FS0115 – FS01 jack mono > jack mono, 2 x 1,5mm2 (15 m) FS026 – FS02 jack mono > XLR/F 3-pin, 2 x 1,5mm2 (6 m) FS0210 – FS02 jack mono > XLR/F 3-pin, 2 x 1,5mm2 (10 m) FS163 – Neutrik FS16 jack mono > Speakon/M, 2 x 1,5mm2 (3 m) FS166 – Neutrik FS16 jack mono > Speakon/M, 2 x 1,5mm2 (6 m) FS1610 – Neutrik FS16 jack mono > Speakon/M, 2 x 1,5mm2 (10 m) FS1620 – Neutrik FS16 jack mono > Speakon/M, 2 x 1,5mm2 (20 m)
Maintenance
The Xi-12B requires almost no maintenance. However, you should keep the unit clean. Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not immerse in liquid. Do not use alcohol or solvents. Keep connections clean. Disconnect electric power, and then wipe the connections with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric power.
Troubleshooting
This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit operates properly, do not carry out following steps.
01) If the device does not operate properly, unplug the device.
02) Check the power from the wall, all cables, etc.
03) If all of the above appears to be O.K., plug the unit in again.
04) If you are unable to determine the cause of the problem, do not open the Xi-12B, as this may
damage the unit and the warranty will become void.
05) Return the device to your Dap Audio dealer.
Product Specifications
Impedance:
4
Continuous power:
300W
Program power:
600W
Peak power:
900W
Components:
12” woofer with 2,5” VC
Frequency response (processed):
42-150 Hz
Frequency response (flat, -10dB):
42-2800 Hz
Recommended HPF:
42Hz, BW-24
Recommended LPF:
150Hz, LR-24
Sensitivity (full space):
99dB/W/m
Peak SPL @1m:
125dB
Normal dispersion (HxV):
360° x 180°
Connectors:
Speakon IN/THRU, 4-pin terminal block IN/OUT
Housing:
Birch Plywood, resistant black finish
Color:
Black (D3442), White (D3443)
Dimensions:
540 x 350 x 513 mm (LxWxH)
Weight:
18,3 kg
Design and product specifications are subject to change without prior notice.
Website: www.Dap-audio.info
Email: service@highlite.nl
10
Xi-12B
Ordercode: D3442/D3443
Dimensions
©2018 DAP Audio
Loading...