Deep Wall Extension Kit For
1/2" Improved Thermostatic Valve
Long thermostatic cartridge stem
Long sleeve
New volume control cartridge (Common part)
Long volume control cartridge stem Long shank
Long screw
Kit A (Extended rough-in range 3 11/16"~4 3/16") Kit B (Extended rough-in range 4 3/16"~4 9/16")
2 7/16"~2 15/16" (62.5~75.5mm)
1 5/8"~2 1/8"
(40.5~53.5mm)
Normal Rough-in range (3 1/8" - 3 5/8")
Finished wall surface
1 15/16"~2 7/16"
(49~62mm)
3 7/16"~3 13/16" (88.5~97.5mm)
4 3/16"~4 9/16" (106~115mm)
1 3/4"~2 1/8" (44~53mm)
surface
2"~2 3/8"
(51~60mm)
2 15/16"~3 7/16" (75.5~88.5mm)
3 11/16"~4 3/16"
(93~106mm)
3 1/8"~3 5/8"
(80~93mm)
1 11/16"~2 3/16"
(43~56mm)
Finished wall surface Finished wall
1 15/16"~2 7/16"
(50~63mm)
Kit A (Extended rough-in range 3 11/16"~4 3/16") Kit B (Extended rough-in range 4 3/16"~4 9/16")
2
The Danze 1/2” thermostatic mixing valve extension kit is designed to provide up to 1 1/4” of additional wall depth adjustment.
A) If the distance from the back of mounting plate to the finished wall surface is between 3 11/16”~4
3/16”, you need to use the extension kit A.
B) If the distance from the back of mounting plate to the finished wall surface is between 4 3/16”~4
9/16” , you need to use the extension kit B.
1. Remove the existing stem extension by
removing the Phillips screw. Extract volume control cartridge from valve: grasp shank with wrench and carefully pull volume control cartridge straight out of socket.
Volume control cartridge
Stem extension
3
2. Install the new volume control valve cartridge (1), long shank (2), long stem (3) and screw (4) in
the pictured order below.
3. Install long sleeve (5), Long thermostatic cartridge stem (6). Reinstall existing screw (7).
1234