DANLERS COPD, COPD BK Installation Notes

Page 1
Variants
Low voltage variants can be supplied, coded by the following sufxes:
• 12VAC 12V - (ac supply) operation
• 12VDC 12V - (dc supply) operation
• 24VAC 24V - (ac supply) operation
• 24VDC 24V - (dc supply) operation
Trouble shooting
The COPD cannot be made to switch on during bright days
• The COPD should have the lux set to inactive via the internal mode button (see diagram B)
The PIR does not detect
• Person is too far from the COPD switch, see detection diagram.
• Person is moving unusually slowly (perhaps when testing). The PIR stops working
• Ensure the unit is mounted correctly so that no water can enter. The PIR False triggers
• Detector is exposed to air movement on breezy days.
Precautions and Warranty
This product conforms to BS EN 60669-2-1 and BS EN 55015.
Please ensure the most recent edition of the appropriate local wiring regulations are observed and suitable protection is provided e.g. a 10 amp circuit breaker and voltage surge protection. Please ensure that this device is disconnected from the supply if an insulation test is made.
This product is covered by a warranty which extends to 5 years from the date of manufacture.
Products available from DANLERS
• PIR occupancy switches • Daylight linked dimmers • Manual high frequency dimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
Please call for more information or a free catalogue.
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK. Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388 E-mail: sales@danlers.co.uk Web: www.danlers.co.uk Company Registered Number 2570169 VAT Registration Number 543 5491 38
01/03/19 INS970 COPD
Installation notes
Compact person detector, PIR switch
COPD COPD BK
DANLERS Compact Person Detector is IP66 rated and can be surface mounted onto an external wall. It incorporates a passive infra-red quad sensor to detect movement of a warm body within the detection zone (diagram A) and the COPD (BK) includes a photocell to monitor the ambient light level.
The detection range is about 10 metres over 120 degrees, the range reduces to about 8m at the extremes to prevent nuisance switching.
On detecting movement, if the ambient light is dark enough, the COPD (BK) will switch the load on. The ambient threshold can be set by the user to between approximately 10 and 1000 lux via the internal LUX adjuster (diagrams B and C). The photocell can be disabled via the internal mode button (see overleaf).
If no more movement is detected within a pre-selected time, then the PIR switch will turn the load off. This time lag can be set via the TIME adjuster to 10 seconds, 20 seconds, 40 seconds, 80 seconds, 2 minutes 30 seconds, 5 minutes,10 minutes, 20 minutes or 40 minutes (diagram D).
Product codes: COPD Grey enclosure COPD BK Black enclosure
Loading
The switch should only be connected to a 230V 50Hz AC supply. These PIR switches can switch up to:
6 amps (1500W) of resistive loads. 6 amps (1500W) of uorescent loads. 3 amps (750W) of electronic and wire wound transformer loads. 2 amps (500W) of CFL, 2D lamps, LED Drivers and LED lamps and ttings. 1 amp (250W) of fans
Minimum load 2W resistive, suitable for most energy saving lamps,
LEDs and emergency ttings.
Page 2
LUX
max min
10 LUX
1000 LUX
TIME
min max
LUX
max min
10 LUX
40m
20m
10m
5m
2.5m
80s
10s
20s
40s
1000 LUX
Installation procedure
1. Please read these notes carefully before commencing work.
In case of doubt please consult a quali ed electrician.
2. The detector should be sited so that it is not shaded from daylight
3. The detector should be mounted between 1 and 2.2 metres high, via any of the four pre-drilled mounting holes only.
4. It must be mounted with the cable entering from below.
5. Make sure the power is isolated from the circuit.
6. The detector should be connected as shown in diagram E L - Live in, N - Neutral in, SL - Switched Line out.
7. IMPORTANT - Replace terminal cover.
8. Once the wiring has been completed and veri ed, switch on the supply
and test the operation.
Lux and Time set-up
For convenience, ensure that the TIME is set to minimum when setting up the LUX level. Afterwards set the TIME to a value suitable for the application.
8. When powered up, (after 1 minute stabilisation time) turn lux pot (diagram C) fully clockwise and time pot fully anticlockwise.
9. Press the MODE button (diagram B) for approximately 0.5s. The LED will go green indicating the LUX cell is active. (Or press and hold button for approx. 4 seconds – LED goes RED indicating Lux cell INACTIVE). Repeating these steps will toggle the functionality.
10. If lux cell active, vacate area until PIR switch switches the load off (should be after 10 seconds).
11. With the LUX as desired on working plane from daylight ONLY (no
arti cial light), wind the lux pot anticlockwise whilst waving your
hand in front of the PIR cell. When the PIR switches the load ON, stop turning the pot. The Lux inhibit level is now set.
12. Turn the PIR time to the desired timeout (diagram D). person is detected, the time lag will start again and the load will stay switched on.
Precondition Power-up Condition
Lux Cell Inactive Relay OFF
Lux Cell Active Relay ON
Lux Cell Active Relay OFF
Lux Cell Inactive Relay ON
Lux Cell Inactive Relay comes ON for 1 Min. After 1 min. ready for detection.
Lux Cell Active Relay stays ON for 1 Min. After 1 min. ready for detection.
Lux Cell Active Relay comes ON for 1 Min. After 1 min. ready for detection.
Lux Cell Inactive Relay stays ON for 1 Min. After 1 min. ready for detection.
Whenever a
A: Detection range
Recommended mounting height 1 to 2.2 metres
Strong detection zone (5m) i.e. person walking towards detector
Secondary detection zone (10m, 8m at extremes) i.e. person walking perpendicular to detector
B: Time/Lux adjusters (inside casing)
Dual colour LED:
RED - PIR active, Photocell inactive
GREEN - PIR and Photocell override ON (passive LUX)
Time Delay Spindle
STATUS
1000
TIME LUX
MODE
10
E: Wiring diagramD: Time adjustment
Inside detector housing
L
optional manual wall switch for overriding off
230 VAC
N
Safety cap
Locate safety cap plastic pins in the hole ‘L’ and second ‘N’ holes above the termination screws. Press firmly to attach.
C: Lux adjustment
Lux Cell Mode
Lux Setting
Use Mode Button to disable
Spindle
LUX (see diagram B)
COPD or COPD BK
SL