Danish Interpretation Systems DCS 6000, RP 6004 User Manual

DCS 6000
User Manual
Danish Interpretation Systems DIS
Digital Conference System
RP 6004 Repeater
Danish Interpretation Systems Operation manual
Copyright © 2003 Danish Interpretation Systems No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the
publisher.
Danish Interpretation Systems Operation manual
Copyright © 2003 Danish Interpretation Systems No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the
publisher.
List of Contents
List of Contents .....................................................3
Document version..............................................3
Important...............................................................4
Compliancy ........................................................4
Installation precautions.....................................4
Cleaning..............................................................4
Repacking...........................................................4
Warranty............................................................4
Description of the system......................................5
Features..............................................................5
System components ...........................................6
Central equipment............................................6
Interpreter and delegate equipment..................6
Unit operating instructions ..................................7
RP 6004 Repeater..............................................7
General description.......................................... 7
Features ........................................................... 7
User Controls, indications & connectors.........7
System design..................................................8
System Setup.......................................................10
General guidelines...........................................10
Typical schematics .......................................... 11
Large size conference microphone system....11
Various configurations with RP 6004 Repeater
and PS 6000 Power Supply...........................12
Appendix.............................................................. 13
Technical appendix.........................................13
Cabling ..........................................................13
Accessories (not supplied)............................. 13
Technical specifications ................................ 14
Document version
Printed: 03-11-2003 Version: B Name: RP6004B.DOC
Danish Interpretation Systems Operation manual
Manual 01 18 04466 Printed in Denmark
4
Important
Compliancy
The equipment has been tested and found to comply with the limits of the following norms and approvals:
EN55013 of 2001 (emission)
EN55020 of 2002 (immunity)
EN60065 of 1998
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. The equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the user manual it may cause harmful interference to radio communications.
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
Installation precautions
Allow adequate air circulation to prevent internal heat built-up. Do not place the unit on a surface (rugs, blankets, etc.) that may block the ventilation holes.
Do not install the unit in a location near heat sources such as radiators or air ducts, or in a place exposed to direct sunlight, excessive dust or humidity, mechanical vibration or shock.
To avoid moisture condensations do not install the unit where the temperature may rise rapidly.
Cleaning
To keep the cabinet in its original condition, periodically clean it with a soft cloth. Stubborn stains may be removed with a cloth lightly dampened with a mild detergent solution. Never use organic solvents such as thinners or abrasive cleaners since these will damage the cabinet.
Repacking
Save the original shipping carton and packing material; they will become handy if you ever have to ship the unit. For maximum protection, re-pack the unit as originally packed from the factory.
Warranty
The individual units in the DCS 6000 system are minimum covered by 12 months warranty against defects in materials or workmanship.
.
Danish Interpretation Systems Operation manual
Manual 01 18 04466 Printed in Denmark
5
Description of the system
Features
The DCS 6000 system has the following main features:
Fully digital
Excellent sound quality
“State of the Art” fully digital integrated
interpretation, discussion and voting system offering interpretation, language distribution, conference microphone and voting facilities with attendance check with Chip Card ™.
New, unique digital DATA and AUDIO bus.
39 incoming channels (8 floor channels + 31
interpreted channels)
33 distributed channel (2 x floor + 31
interpreted channels)
The Delegate and Interpreter units are powered
and controlled by the CU 6010 Central Unit, which drives up to app. 200 units on 4 chains.
EX 6010 Extension Units or PS 6000 Power
Supplies available if more units are required
A total of 4000 units (delegate or interpreter
units) can be connected to the system.
Using screened CAT5 cabling (FTP or STP)
ensuring a very cost effective installation and easy set-up of portable systems
Firmware in Delegate units, Interpreter Units,
Central Units etc. upgradeable through RS232 on Central Unit
Can be operated with or without a PC.
Added functionality and comprehensive
features provided by SW 6000 software package running on PC
RS232/RS422 connection on CU 6010 for
external operation of the system of a PC or control system such as AMX or Crestron
The SW 6000 is an optional software package, which expands the functionality of the DCS 6000 system. The software runs on standard computer technology (Standard PC with Windows 2000 or XP).
Main features of the SW 6000 are:
Microphone management
Mimic panel operation
Interpretation management
Voting management
Message handling
Agenda handling
Data stored on SQL data base for easy
export/import of data as well as easy links to external databases
Multi language user interfaces
Supports different user type with different
priorities, user interfaces and control possibilities
Variety of printing facilities such as speaker’s
log, voting results, delegates list etc.
Danish Interpretation Systems Operation manual
Manual 01 18 04466 Printed in Denmark
6
System components
The DCS 6000 system consists of various units.
Central equipment
CU 6000 Central Unit with built-in DCS-LAN
controller and power supply
CU 6010 Central Unit with built-in DCS-LAN
and power supply EX 6010 Extension Unit PS 6000 Power Supply AO 6008 Audio Output box RP 6004 Repeater for four chains
Interpreter and delegate equipment
IS 6132P Interpreter Set
LS 6032P Interpreter Loudspeaker CS 6032P Channel selector (portable) CS 6032F Channel Selector (flush mounted) DM 6010P Delegate Unit (portable) DM 6070P Delegate Unit (portable) with two
built in channel selectors CM 6010P Chairman Unit (portable) CM 6060P Chairman Unit (portable) with one
built in channel selectors MU 6040 Microphone Unit for use with
customised front plate with
Loudspeaker, Microphone and
Buttons. Available in Delegate (D)
and Chairman (C) version JB 6002 Junction Box with 2 outputs JB 6004 Junction Box with 4 outputs
Danish Interpretation Systems Operation manual
Manual 01 18 04466 Printed in Denmark
7
Unit operating instructions
RP 6004 Repeater
General description
The RP 6004 Repeater provides Repeater and Splitter functionality for the DCS 6000 system. One CU 6010 Central Unit is needed in each DCS 6000 system, however for expansion of the system the RP 6004 Repeater is suitable.. The RP 6004 consist of two main parts:
Repeater /splitter board with 4 individual
repeated outputs
Features
The main features of the RP 6004 Repeater are:
4 outputs for connection to Delegate Units,
Interpreter Units etc.
Loop through connectors for connection
additional RP 6004 or other units, which are part of the DCS 6000 system
Delayed switching on of power to the four
chains, to minimise the total ‘switch-on’ current on the Mains supply.
Designed in compact cabinet for easy installing
remotely.
User Controls, indications & connectors Front plate layout
Front plate controls
The RP 6004 Repeater does not feature any controls or displays, however the following indications and connectors are available:
q Loop through connectors
RJ45 connector, 2 pieces DCS-LAN connectors for connection to the CU
6000/CU 6010 and for connection to other units with DCS-LAN connector, such as more RP 6004.
q Repeated Chain 1, 2, 3 & 4
RJ45 connector, 4 pieces
DCS-LAN connectors for connection to DM/CM6xxx, IS6032, CS6032, EX6010, AO6008 etc. For connecting Interpreter Sets for up to 16 languages. If more languages are required, Interpreter sets for those languages have to be connected to Chain B1 or B2.
q Power LED
Those LED light up when Power is available on the connector next to the LED
q Incoming data LED
Those LED flashes, when the units received incoming data from connected units on the connector next to the LED.
Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark
8
System design
There are no settings to be done on the RP 6004 Repeater.
However it is important to observe, that the unit is only repeating one of the chains on the CU 6010 Central Unit.
And as so, the specification, which applies to each of the chain outputs on the CU 6010 Central Units does also apply to all the repeated outputs in total.
So when designing a system to incorporate RP 6004 Repeaters, bare in mind, that as the RP 6004
Repeater is repeating only one of the four outputs A (A1 or A2) or B (B1 or B2) the max. number of languages configured on the four outputs (1, 2, 3 and 4) is totally max. 16.
If more languages are required, Interpreter sets for those languages have to be connected either to an other RP 6004 Repeater, which is connected to the other of the two chains (A or B) on the CU 6010, or directly to the other of the two chains (A or B) on a CU 6010.
‘Repeated chain’ connector
When connecting the RP 6004 Repeaters to the CU 6010 the first EX is connected to the ‘Loop through’ connector. The next RP 6004 Repeaters can be connected to either the other ‘Loop through’ connector or to one of the ‘Repeated out’
connectors. If using the ‘Repeated’ outputs two more RP 6004 Repeaters can be connected extending the maximum cable length in one chain up to 680 m. The above schematic is showing the connection using the ‘‘Repeated out’ connectors.
Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark
9
‘Loop through’ connector
When connecting a number of RP 6004 Repeaters to the CU 6010 an almost unlimited number of EX can be connected by using the ‘Loop through’ connector. The practical limitation is the maximum cable length in one chain, which is 200 m. The following schematic is showing the connections using the ‘Loop through’ connectors.
A combination of the two methods of connection can be seen in the section ‘Typical Schematics’.
Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark
10
System Setup
General guidelines
Connect the RP 6004 to the various units using Cat 5 FTP or STP cables. Please observe the following guide lines:
Maximum cable length in one chain is 200
m without repeater. This includes interconnection cables between the units. The max. usable cable length depends on the units connected and length of feeding cables etc.
Maximum cable length in one chain when
using repeaters is 680 m.
As the RP 6004 Repeater is repeating only
one of the four outputs A (A1 or A2) or B
(B1 or B2) the max. number of languages configured on the four outputs (1, 2, 3 and
4) is totally max. 16. If more languages are required, Interpreter
sets for those languages have to be connected to both chains (A or B) on the CU 6010. Normally the languages are supposed to be divided equally on chains A (A1 or A2) and B (B1 or B2).
If the last unit in one chain is a CS 6032
Channel Selector, this units has to be terminated with an external termination, as the CS 6032 does not have an internal termination.
Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark
11
Typical schematics
The following schematics are showing various configurations:
Large size conference microphone system
Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark
12
Various configurations with RP 6004 Repeater and PS 6000 Power Supply
Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark
13
Appendix
Technical appendix
Cabling CAT5
The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables/connectors. And EIA 568-B wiring shall be used.
But use only FTP or STP cables/connectors and not UTP.
How to wire a CAT5 (EIA 568-B) Cable:
Pin
Connector #1 Connector #2
1 ORG/WHT ORG/WHT 2 ORG ORG 3 WHT/GRN WHT/GRN 4 BLU BLU 5 BLU/WHT BLU/WHT 6 GRN GRN 7 BRN/WHT BRN/WHT 8 BRN BRN
Note. If other colour codes are used then the four
pairs are connected as follows:
Pair 1: Pin 1 & 2 Pair 2: Pin 3 & 6 Pair 3: Pin 4 & 5 Pair 4: Pin 7 & 8 The phase of the pairs must be correct.
Accessories (not supplied)
Cat 5e Connection Cables (AWG24)
EC 6000-..5 Connection Cable 0,5 m ..................... 10 03 12500
EC 6000-01 Connection Cable 1 m ........................10 03 13101
EC 6000-02 Connection Cable 2 m ........................10 03 13201
EC 6000-05 Connection Cable 5 m ........................10 03 13501
EC 6000-10 Connection Cable 10 m ......................10 03 14102
EC 6000-20 Connection Cable 20 m ...................... 10 03 14202
EC 6000-50 Connection Cable 50 m ...................... 10 03 14502
Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark
14
Technical specifications General
Power consumption .................................................max. 10VA
Temperature to guarantee specified performance
..............................5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
.......................... -20 Deg C. to 60 Deg C. (10 to 80% humidity)
Weight.............................................................................. 5,5 kg
Dimensions (W x H x D)............................264 x 42 x 128 mm
Accessories supplied...............................................User manual
..................................................................................Main cable
Connectors
DCS-LAN loop through ........................................2 pieces RJ45
DCS-LAN repeated output....................................4 pieces RJ45
Specifications are subject to change without notice.