Danish Interpretation Systems DCS 6000, EX 6010 User Manual

DCS 6000
User Manual
DIS
Digital Conference System
EX 6010 Extension Unit
Extension power supply with repeater for increasing the system capacity in DDS 5900 and DCS 6000 Systems
DIS User Manual
Copyright © 2007-2012 DIS User Manual EX 6010 rev F.doc 10-12-2012 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the
publisher.
DIS User Manual
Copyright © 2007 DIS User Manual EX 6010 rev F.doc 10-12-2012 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the
publisher.
List of Contents
List of Contents ................................................................. 3
Important ........................................................................... 4
Important Safeguards ................................................ 4
Labels ..................................................................................... 5
Note for Power Connections ........................................ 5
Power Disconnect ............................................................. 6
Compliancy .................................................................... 6
Cleaning .......................................................................... 6
Repacking ...................................................................... 6
Warranty ........................................................................ 7
DCS 6000 Conference System ...................................... 8
Description of the DCS 6000 system...................... 8
System components .................................................... 9
Central equipment etc. ................................................... 9
Interpreter equipment ................................................... 9
Conference equipment and channel selectors ..... 9
Accessories .......................................................................... 9
Operating instructions ................................................ 10
General description ................................................. 10
Features ....................................................................... 10
User Controls, indications & connectors ........... 10
Front plate layout ........................................................... 10
Back panel layout ............................................................ 11
System design ............................................................. 12
‘Repeated chain’ connection ...................................... 12
‘Loop through’ connection .......................................... 13
General Guidelines ....................................................... 14
Installation .................................................................. 14
Cabling guidelines .................................................... 14
Max. number of units to be connected ............... 15
Typical schematics ................................................... 17
EX 6010 versus RP 6004 Repeater and PS 6000
Power Supply ............................................................. 17
Technical Specifications ............................................. 18
Unit Specification ...................................................... 18
Connection Details .................................................... 19
Accessories .................................................................. 19
DIS User Manual
User Manual EX 6010 rev F.doc
4
Important
Important Safeguards
1 Read these instructions - All the safety and
operating instructions should be read before the apparatus or system is operated.
2 Keep these instructions - The important
safety instructions and operating instructions should be retained for future reference.
3 Heed all warnings - All warnings on the
apparatus and in the operating instructions should be adhered to.
4 Follow all instructions - All instructions for
installation or use/operating should be followed.
5 Do not use this apparatus near water - Do
not use this apparatus in a water or moistures environment - for example, near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement, near a swimming pool, in an unprotected outdoor installation, or any area which is classified as a wet location.
6 Warning: To reduce the risk of fire or
electric shock, do not expose this apparatus to rain or moisture and no objects filled with liquids, such as vases, should be placed on this apparatus.
7 Clean only with dry cloth - Unplug the
apparatus from the outlet before cleaning. Do not use liquid cleaners or aerosol cleaners.
8 Do not block any ventilation openings.
Install in accordance with the manufacturer’s instructions - Openings in the
enclosure, if any, are provided for ventilation and to ensure reliable operation of the apparatus and to protect it from overheating. These openings must not be blocked or covered. This apparatus should not be placed in a built-in installation unless proper ventilation is provided or the manufacturer’s instructions have been adhered to.
9 Do not install near any heat sources such as
radiators, heat registers, stoves, air ducts,
or other apparatus (including amplifiers) that produce heat.
10 Do not install the unit in a place exposed to
direct sunlight, excessive dust or humidity, mechanical vibration or shock.
11 To avoid moisture condensations do not
install the unit where the temperature may rise rapidly.
12 Do not defeat the safety purpose of the
polarized or ground-type plug. A polarized
plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
13 Protect the power cord from being walked
on or pinched particularly at plug, convenience receptacles, and the point where they exit from the apparatus.
14 Only use attachments/accessories specified
by the manufacturer. Any mounting of the
apparatus should follow the manufacturer’s instructions, and should use a mounting accessory recommended by the manufacturer.
15 Use only with the cart, stand, tripod, bracket
or table specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the
cart/apparatus combination to avoid injury from tip-over ­Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to
overturn.
DIS User Manual CU 6105
User Manual EX 6010 rev F.doc
5
16 Unplug this apparatus during lighting
storms or when unused for long periods of time. – Not applicable when special functions
are to be maintained, such as evacuation systems.
17 Refer all servicing to qualified service
personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
18 Replacement Parts - When replacement parts
are required, be sure the service technician has used replacement parts specified by the manufacturer or having the same characteristics as the original part.
Unauthorized substitutions may result in fire, electric shock or other hazards.
19 Safety Check - Upon completion of any service
or repairs to this apparatus, ask the service technician to perform safety checks to determine that the apparatus is in proper operating condition.
20 Overloading - Do not overload outlets and
extension cords as this can result in a risk of fire or electric shock.
21 Power Sources - This apparatus should be
operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply you plan to use, consult your appliance dealer or local power company. For apparatuses intended to operate from battery power, or other sources, refer to the operating instructions.
22 Power Lines - An outdoor system should not
be located in the vicinity of overhead power lines or other electric light or power circuits, or where it can fall into such power lines or circuits. When installing an outdoor system, extreme care should be taken to keep from activating such power lines or circuits, as contact with them might be fatal.
23 Object and Liquid Entry - Never push objects
of any kind into this apparatus through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock.
Never spill liquid of any kind on the apparatus. Should any liquid or solid object fall into the cabinet, unplug the unit and have it checked by qualified personnel before operating it further.
Labels
“Lightning Flash Symbol” with the lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of un-insulated "dangerous voltage" within the product enclosure that may be of sufficient magnitude to
constitute a risk of shock to persons.
“Exclamation Point Symbol” with the exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature
accompanying the product.
Note for Power Connections
Check that the voltage of your local power supply is within the operating voltage of the unit. If a voltage conversion is required, consult your DIS dealer or qualified personnel.
Set the Power switch to ‘Off’ if it is not used for several days.
Important: The equipment must be connected to earth (ground)
The wires in the main lead supplied with the equipment are colored in accordance with the following codes:
Green-and-yellow Earth (Ground)
DIS User Manual CU 6105
User Manual EX 6010 rev F.doc
6
Blue Neutral Brown Live
The green-and-yellow wire must be connected to the terminal in the plug marked with the letter E or with the safety earth symbol or marked with green-and­yellow color.
The blue wire must be connected to the terminal marked with the letter N or marked with black color.
The brown wire must be connected to the terminal marked with the letter L or marked with red color.
For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible.
Power Disconnect
Apparatuses with or without On/Off switches have power supplied to the apparatus whenever the power cord is inserted into the power source; however, the apparatus is operational only when the On/Off switch is in the On position. The power cord is the main power disconnect for all apparatuses.
Compliancy
The equipment has been tested and found to comply with the limits of the following standards for digital devices:
EN55103-1 (Emission)
EN55103-2 (Immunity)
EN60065 safety
UL6500 safety
The device complies with part 15 of the FCC rules. Operation is subject to the following conditions: (1) The device may not cause harmful interference, and (2) the device must accept any interference received, including interference that may cause undesired operation.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in residential, commercial or light industrial environments. The equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the user manual it may cause harmful interference to radio communications.
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
Operation of this equipment in residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Intentional or unintentional changes or modifications not expressly approved by the party responsible for compliance shall not be made. Any such changes or modifications could void the user’s authority to operate the equipment.
If necessary, the user should consult the dealer or an experienced radio/ television technician for corrective action.
Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Cleaning
To keep the cabinet in its original condition, periodically clean it with a soft cloth. Stubborn stains may be removed with a cloth lightly dampened with a
mild detergent solution. Never use organic solvents such as thinners or abrasive cleaners since these will damage the cabinet.
Repacking
Save the original shipping cardboard box and packing material; they will become handy if you ever have to
ship the unit. For maximum protection, re-pack the unit as originally packed from the factory.
DIS User Manual CU 6105
User Manual EX 6010 rev F.doc
7
Warranty
The units are minimum covered by 24 months warranty against defects in materials or work­manship.
DIS User Manual CU 6105
User Manual EX 6010 rev F.doc
8
DCS 6000 Conference System
Description of the DCS 6000 system
DCS 6000 Digital Conference System is a system to be used at meetings, where a number of people are addressing the ‘Floor’ in a structured manor. The audio from the Conference units can be heard in the built in loudspeakers in the units.
The system does also allow for simultaneous interpretation for international conferences where multiple languages are used.
To enable all participants to understand the proceedings, interpreters can simultaneously translate the speaker’s language as required. These interpretations are distributed through the connected Conference units and delegates can select the language of their choice and listen to it through headphones.
DCS 6000 Digital Conference System comprises of one CU 6105 or one CU 6110 Central Unit and a number of Conference Units, Gooseneck Microphones and other accessories depending on the system configuration.
The DCS 6000 system has the following main features:
Fully digital
Excellent sound quality
“State of the Art” fully digital integrated
interpretation, discussion and voting system offering interpretation, language distribution, conference microphone and voting facilities with attendance check with Chip Card ™.
Digital transmission of audio from/to the
Conference unit to/from the central unit using a unique digital DATA and AUDIO bus named DCS­LAN.
Control of up to 4000 conference units. This
number does not include Channel Selectors, Repeaters etc. In practical use there are no limits for the number of Channel Selectors in a system.
Delegate and Interpreter units are powered and
controlled by the CU 6105 or CU 6110 Central Unit.
EX 6010 Extension Unit or PS 6000 Power
Supplies is available if more units are required.
Delayed switching on of power to the chains, to
minimize the total ‘in-rush’ current on the Mains supply
Designed for 31 interpreted channels and 8 open
microphones
Audio scrambling of the audio to avoid
eavesdropping.
Designed in a standard 1HE 19” cabinet.
TCP/IP connection on CU 6105 and CU 6110 for
external operation of the system using a PC or control system such as AMX ® or Crestron ®.
Functionality on the CU 6105 and CU 6110
depends on the Feature License uploaded into the unit.
Firmware in Delegate units, Interpreter Units,
Central Units etc. is upgradeable
Operated either stand alone or from a PC using
the CU browser or using SW 6000 software.
Added functionality and comprehensive features
provided by SW 6000 software package running on PC
The SW 6000 is an optional software package, which expands the functionality of the DCS 6000 system. The software runs on standard computer technology (Standard PC with Windows 7, Server 2008 etc.).
Main features of the SW 6000 are:
Microphone management
Mimic panel operation
Interpretation management
Voting management
DIS User Manual CU 6105
User Manual EX 6010 rev F.doc
9
Message handling
Agenda handling
Data stored on SQL data base
Web service interface available for easy links to
external applications
Multi language user interfaces
Supports different User types with different
priorities, user interfaces and control possibilities
System components
The CU 6105 Central Unit supports all available units in the DCS 6000 series:
Central equipment etc.
CU 6105 Central Unit, controls max. 500 units CU 6110 Central Unit, controls max. 4000 units EX 6010 Extension Unit PS 6000 Power Supply AO 6004 Audio Output box AO 6008 Audio Output box RP 6004 Repeater for four chains JB 6104 Junction Box with 4 outputs
Interpreter equipment
IS 6132 P Interpreter Set LS 6132 P Interpreter Loudspeaker
Conference equipment and channel selectors
DC 6990 P Conference Unit (portable) with touch
screen with two built-in channel selector, Chip-card and 5 voting buttons, configurable as Delegate, Dual Delegate or Chairman.
DC 6120 P Conference Unit (portable) DC 6190 P Conference Unit (portable) with
two built-in channel selectors
DM 6680 P Conference Unit (portable) with
voting
CM/DM 6080 F Conference Unit (portable) with
built-in channel selectors
DM 6620 F Conference Unit (flush mounted)
with, Chip-card and 5 voting buttons
CM/DM 6680 F Conference Unit (flush mounted)
with one built-in channel selector, Chip-card and 5 voting buttons
MU 6040 C/D Microphone Unit for use with
FD/FC front plate with Loudspeaker, Microphone and Buttons. Available in Delegate (D) and Chairman (C) version
MU 6042 D Dual Microphone Unit for use with
FD/FC front plate with Loudspeaker, Microphone and two delegate Buttons
DV 6501 F Voting Unit AM 6040 Ambient Noise Microphone CS 6340 F V/H Channel Selector (flush mounted)
Accessories
In addition to the unit a number of accessories are available like:
Storage Boxes
GM 6523 Gooseneck Microphone, 40 cm
GM 6524 Gooseneck Microphone, 50 cm
GM 6622 Shotgun Microphone
DH 6021 Delegate Headphone
For detailed instruction in how to use the above units, please refer to the User Manuals for the relevant products.
DIS User Manual CU 6105
User Manual EX 6010 rev F.doc
10
Operating instructions
General description
The EX 6010 Extension Unit provides additional Power Supplies, Repeater and Splitter functionality for the DCS 6000 system. One CU 6105 or CU 6110 Central Unit is needed in each DCS 6000 system, however for expansion of the system the EX 6010 Extension Unit is suitable. The EX 6010 consist of two main parts:
Repeater/splitter board with 4 individual outputs
4 individual power supplies
Features
The main features of the EX 6010 Extension Unit are:
Built in Power Supplies for app 200 units
(Delegate) or app. 600 Channel Selectors
4 outputs for connection to Delegate Units,
Interpreter Units etc.
Loop through connectors for connection
additional EX 6010 or other units, which are part of the DCS 6000 system
Delayed switching on of power to the four chains,
to minimise the total ‘in rush’ current on the Mains supply.
Designed in a standard 2HE 19” cabinet.
User Controls, indications & connect ors
Front plate layout
Front plate controls
The EX 6010 Extension Unit features the following controls and display:
Power Led
When power is switched ON at the CU 6105 or CU 6110 Central Unit any connected EX 6010 Extension Units will automatically be powered up. An LED indicates when power is switched ON.
Fault LED
This indication lights up, if the internal power supply is malfunctioning i.e. because of overheating or overload of a chain.
The Fault LED will always light up some seconds after the unit is switched on caused by the delayed switching on of the four supplies.
As a warning the light is flashing at an internal temperature above 45°C. At a temperature above 55°C or if one of the DCS-LAN outputs is supplying no voltage, the LED is lighting constantly.
Please note that the maximum ambient temperature for the CU 6105 or CU 6110 is 40 deg. Celsius.
DIS User Manual CU 6105
User Manual EX 6010 rev F.doc
11
Back panel layout
Connectors
Mains Power connector
Connection for mains power. See specs.
Loop through connectors
RJ45 connector, 2 pieces with auto-termination
DCS-LAN connectors for connection to the CU 6105 or CU 6110 and for connection to other units with DCS­LAN connectors, such as more EX 6010.
Repeated Chains 1, 2, 3 & 4
RJ45 connector, 4 pieces
Those connectors are DCS-LAN connectors for connection to DM/CM 6xxx, IS 6132, CS 6032, EX 6010, AO 6004/6008 etc.
Power LED’s
Those LED’s light up when Power is available on the connector next to the LED and only if the voltage is over 24V (not overloaded).
Incoming data LED’s
Those LED’s lights up, when the unit is received in­coming data from connected units on the connector next to the LED.
Outgoing data LED
This LED lights up when outgoing data is received from the central unit
Danish Interpretation Systems User Manual
User Manual EX 6010 rev F.doc
12
System design
There are no settings to be done on the EX 6010 Extension Unit.
However it is important to observe, that the unit is only repeating one of the chains on the CU 6105 or CU 6110 Central Unit.
So when designing a system to incorporate EX 6010 Extension units, bare in mind, that as the EX 6010 Extension Unit is repeating only one of the two outputs on CU 6105 or one of the four outputs on CU
6110, the max. number of languages configured on the four outputs (1, 2, 3 and 4) is totally max. 16.
If more languages are required, Interpreter sets for those languages have to be connected either to another EX 6010 Extension Unit, which is connected to another of the four chains on the CU 6110, or directly to one other of the four chains on a CU 6110.
‘Repeated chain’ connection
Figure 0-A Repeated Chain connection
When connecting the EX 6010 Extension Units to the CU 6105 or CU 6110, the first EX is connected to the ‘Loop through’ connector.
The next EX 6010 Extension units can be connected to either the other ‘Loop through’ connector or to one of
the ‘Repeated out’ connectors. If using the ‘Repeated’ outputs two more EX 6010 Extension units (or RP 6004 Repeaters) can be connected extending the maximum cable length in one chain up to 680 m. The above schematic is showing the connection using the ‘‘Repeated chains’ connectors.
Danish Interpretation Systems User Manual
User Manual EX 6010 rev F.doc
13
‘Loop through’ connection
When connecting a number of EX 6010 Extension Units to the CU 6105 or CU 6110 an almost unlimited number of EX 6010 can be connected by using the ‘Loop through’ connector.
However the practical limitation is the maximum cable length in one chain, which is 200 m and the supply of power to the ‘Loop Through’ connectors at the EX 6010.
The following schematic is showing the connections using the ‘Loop through’ connectors.
Figure 0-B Loop through connection
Danish Interpretation Systems User Manual
User Manual EX 6010 rev F.doc
14
General Guidelines
Installation
The EX 6010 is suitable for either table-top or 19-inch rack-mounted use. Two mounting brackets (for rack mounting) are supplied.
When installing in a 19” rack the supplied 19” brackets shall be fixed to the front side of the CU 6105 Central Unit by unscrewing the crews holding the top and button cover and then fix the brackets using the same screws.
The unit has a low noise built-in fan taking air in at the left side of the unit and blowing the hot air out at the right side. That allows units in 19” racks to be
stacked close with other units without extra room for cooling air between them.
Please check that other units in the rack will allow this.
Connect the EX 6010 to the various DCS 6000 units using CAT5e cabling (F/UTP or U/FTP) screened cables following the guidelines in the next chapter.
The operation and installation of the various DCS 6000 units is found in the User Manuals for the specific units.
Cabling guidelines
The Conference Units are connected to the CU 6105 Central Unit using Cat5e F/UTP or U/FTP screened cables and the following guidelines have to be observed:
The Conference units are daisy chain connected
to the central unit
The number of units, which can be connected to
EX 6010, depends on length of the feeding cable and the length of the cable between each unit.
If the feeding cables are short and the cables between the units are short, more units can be connected than if the feeding cable is long and/or the cables are long between the units.
Maximum cable length in one chain is 200 m
(before using EX 6010 or a RP 6004 Repeater in a chain). This includes interconnection cables between the units.
Maximum cable length in one chain when using
EX 6010 or RP 6004 Repeaters and Cat5e cables is 680 m.
Cables must be AWG24 if the number of units in
the tables in section ‘0
Max. number of units to be
connected’ is to be used. AWG26 cables will not
allow as many units. DIS cables series EC 6001-xx are all AWG 24.
It is desirable that the square of the feeding
cables are as big as possible to minimize the voltage drop in the cables. Cat5e cables are delivered in various gauges:
The following table shows the Diameter/square for various AWG types:
Type
Diameter
Square
AWG22
0.64 mm
0.32 mm2
AWG23/1
0.57 mm
0.25 mm2
AWG24
0.53 mm
0.22 mm2
AWG26
0.42 mm
0.14 mm2
Although the DCS-LAN chain output connectors have a 125 W supply, this 125 W power is not all available with long cables, as there will be a power drop in the feeding cable from the EX 6010 to the units connected.
Please consult the next sections for details about the number of units, which can be connected depending on the cable length.
DIS User Manual
User Manual EX 6010 rev F.doc
15
Max. number of units to be connected
The following tables shows the maximum number of units, which can be connected to a CU 6105 Central Unit.
In the tables the ‘Feeding Cable’ is defined as the cable between the EX 6010 and the first Conference Unit and the ‘Interconnecting Cable is defined as the cable connecting two conference units.
The following tables show the maximum number of units, which can be connected to each DCS-LAN chain output
The same numbers are valid for the output of a PS
6000.
DC 6120 P, DC 6190 P, DM 6680 P Conference Units
Length of
Feeding Cable
Type CAT5e
AWG24
Length of inter
connecting Cable, Type
CAT5e AWG24
Total cable
length
Max. number
of units pr
output
10 m
1 m
51 m
42
30 m 1 m 67 m 38
50 m 1 m 83 m 34
100 m 1 m 122 m 23
150 m
1 m
165 m
16
10 m 2 m 88 m 40
30 m 2 m 98 m 35
50 m 2 m 108 m 30
100 m
2 m
140 m
21
150 m 2 m 178 m 15
Figure 0-A DC 6120 P, DC 6190 P or DM 6680 P
Conference Units connected
DC 6990 P Conference Unit
Length of
Feeding Cable
Type CAT5e
AWG24
Length of inter
connecting
Cable, Type
CAT5e AWG24
Total cable
length
Max. number
of DC 6990 P
pr. output
10 m 1 m 35 m 26
30 m
1 m
53 m
24
50 m 1 m 70 m 21
100 m 1 m 112 m 13
150 m 1 m 158 m 9
10 m
2 m
56 m
25
30 m 2 m 72 m 22
50 m 2 m 90 m 19
100 m 2 m 124 m 13
150 m
2 m
166 m
9
Figure 0-B DC 6990 P Conference Units connected
CM/DM 6080 F / DM 6620 F Chairman/Delegate
Length of
Feeding Cable
Type CAT5e
AWG24
Length of inter
connecting
Cable, Type
CAT5e AWG24
Total cable
length
Max. number
of DC 61xxP
pr. output
10 m 1 m 39 m 30
30 m 1 m 56 m 27
50 m 1 m 73 m 24
100 m
1 m
115 m
16
150 m 1 m 160 m 11
10 m 2 m 64 m 28
30 m 2 m 78 m 25
50 m
2 m
94 m
23
100 m 2 m 130 m 16
150 m 2 m 170 m 11
Figure 0-C CM/DM 6080 F or DM 6620 F
Chairman/Delegate Units connected
CM/DM 6680 F Chairman/Delegate Units connected
Length of
Feeding Cable
Type CAT5e
AWG24
Length of inter
connecting
Cable, Type
CAT5e AWG24
Total cable
length
Max. number
of DC 61xxP
pr. output
10 m 1 m 35 m 27
30 m 1 m 53 m 24
50 m
1 m
70 m
21
100 m 1 m 113 m 14
150 m 1 m 159 m 10
10 m 2 m 58 m 25
30 m
2 m
72 m
22
50 m 2 m 88 m 20
100 m 2 m 126 m 14
150 m 2 m 166 m 9
Figure 0-D CM/DM 6680 F Chairman/Delegate Units
connected
DIS User Manual
User Manual EX 6010 rev F.doc
16
MU 6040 C/D and MU 6042 D
Length of
Feeding Cable,
Type CAT5e
AWG24
Cable length
between each
MU 6040
Total cable
length
Max. number
of MU 6040
pr. output
10 m 2 m 168 m 80
30 m 2 m 178 m 75
50 m 2 m 188 m 70
100 m
2 m
200 m
51
150 m 2 m 200 m 26
100 m 1 m 151 m 52
150 m 1 m 191 m 42
Figure 0-E MU 6040 C/D and MU 6042 D without
connected loudspeaker.
Note: The numbers are valid with no audio in loudspeaker or no loudspeaker connected to each unit. If loudspeakers are used, then use the figures for DC 6120 P or DC 6190 P.
IS 6132 P Interpreter Units
Length of Feeding
Cable, Type CAT5e
AWG24
Length of inter-
connecting Cables,
Type CAT5e AWG24
Max. number of units
pr output
All ON ½ ON 1/3 ON
10m 2 m 54 x x
30m 2 m 49 57 60
50m 2 m 44 51 x
100m
2 m
35 40 x
150m 2 m 25 30 x
Figure 0-F IS 6132 P Interpreter Units connected. The
numbers are with no loudspeakers connected.
Note: The number of units is dependent of how many interpreter sets there are per booth (or language), as there only can be one set switched ON per language (channel).
IS 6132 P Units and JB 6104
Length of
Feeding Cable,
Type CAT5e
AWG24
Length of
cable
between
booths
Number
of
booths
Number
of IS
6132/
booths
Number of
LS 6132 P/
booths
10 m 5 m 19 4 0
10 m 5 m 12 4 4
30 m 5 m 17 4 0
30 m
5 m
10 4 4
50 m 5 m 15 4 0
50 m 5 m 9 4 4
100 m 5 m 11 4 0
100 m
5 m 7 4
4
150 m 5 m 8 4 0
150 m 5 m 5 4 4
Figure 0-G IS 6132 P Units and JB 6104 a nd with/without
LS 6132 P Loudspeaker connected.
CS 6340 F Channel Selector
Length of
Feeding Cable,
Type CAT5e
AWG24
Length of Inter-
connecting cable, Type
CAT5e AWG24
Total cable
length
Max. number
of CS 6340 pr
output
30 m 1 m 139 m 110
50 m 1 m 144 m 95
100 m
1 m
184 m
85
150 m 1 m 200 m 51
10 m 2 m 200 m 96
30 m 2 m 200 m 86
50 m
2 m
200 m
76
100 m
2 m
200 m
51
150 m 2 m 200 m 26
Figure 0-H CS 6340 F Channel Selector w/back light on
DIS User Manual
User Manual EX 6010 rev F.doc
17
Typical schematics
The following schematics are showing a typical configuration with use of EX 6010.
Figure 0-A System with EX 6010
EX 6010 versus RP 6004 Repeater and PS 6000 Power Supply
The next schematic shows, that the functionality of the EX 6010 equals one RP 6006 Repeater and four PS 6000 Power Supplies.
Figure 0-A EX 6010 versus RP 6004 and PS 6000
DIS User Manual
User Manual EX 6010 rev F.doc
18
Technical Specifications
Unit Specification
General
Power consumption ......................................................... max. 600W
In-rush current .............. max. 30A @115V or max. 60A@230V
Mains voltage: ............................................... 100 - 240V, 50 - 60Hz
Supply voltage for units (each A1, A2, B1, B2)....... 48V/125W
Max. power load on Loop Through connectors ................. 7.5W
Temperature to guarantee specified performance
................................... 5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
............................... -20 Deg C. to 60 Deg C. (10 to 80% humidity)
Weight ............................................................................................... 5.5 kg
Dimensions (W x H x D) ......... 425 (483) x 87 x 317 (357) mm
dimensions in bracket are including 19” brackets
Connectors
DCS-LAN loop through ................................................ 2 pieces RJ45
DCS-LAN repeated output ......................................... 4 pieces RJ45
Cabling and System Limits
Cable type (min. specification) ....... Cat5e, AWG 24, screened
Maximum cable length in one chain .................................... 200 m
System Environmental Conditions
Working condition ........................................... Fixed, stationary or
transportable
Temperature range
To guarantee specified performance ...... 5 Deg C. to 40 Deg C.
Storage temperature .................................. -20 Deg C. to 60 Deg C
Maximum relative humidity .................................................. < 80%
Approvals
EMC emission According to harmonized
standard EN 55103-1 and FCC rules part 15, complying with the limits for a class A digital devices
EMC immunity According to harmonized
standard EN 55103-2
EMC approvals Affixed with the CE mark
ESD According to harmonized
standard EN 55103-2
Mains harmonics According to harmonized
standard EN 55103-1
Environmental requirements ..................... Contains no banned
substances as specified in UAT-0480/100 (e.g. no cadmium or asbestos)
Accessories supplied .................................................. User manual
.................................................................................................. Mains cable
.................................................................... 5 pieces termination plugs
Specifications are subject to change without notice
DIS User Manual
User Manual EX 6010 rev F.doc
19
Connection Details
Mains
Blue Neutral Brown Live Green/Yellow Earth (Ground)
DCS-LAN Chain
The DCS 6000 system uses Cat5e, Cat6 or Cat7 F/UTP or U/FTP cables with screened RJ45 connectors.
EIA 568-B wiring shall be used.
Important: The names of Cat5/6/7 cable type have changed.
Old name New name
FTP F/UTP
STP U/FTP
UTP U/UTP
Important: Use only F/UTP or U/FTP (screened) cables
and screened RJ45 connectors and not U/UTP cable, which are unscreened.
How to wire a Cat5e (EIA 568-B) cable to a RJ45 con.:
Pin Function Connector #1 Connector #2
1 In-going + ORG/WHT ORG/WHT
2 In-going - ORG ORG
3 +48V GRN/WHT GRN/WHT
4 0V BLU BLU
5 0V BLU/WHT BLU/WHT
6 +48V GRN GRN
7 Outgoing - BRN/WHT BRN/WHT
8 Outgoing + BRN BRN
Important: If other color codes are used then the four pairs
are connected as follows:
Pair 2: Pin 1 & 2 Pair 3: Pin 3 & 6 Pair 1: Pin 4 & 5
Pair 4: Pin 7 & 8
The phase of the pairs must be correct and the wiring spec. as stated in Cat5e (EIA 568-B) have to be followed.
Note: Cat6 and Cat7 cables can normally only be terminated in sockets (female) and not in cable plugs.
Cat6 and Cat7 can thus only be used for feeding cables terminating in wall outlets or patch panels.
Accessories
Cat5e Connection Cables (AWG24)
EC 6001-0.5 Connection Cable 0.5 m ..................... 10 03 22500
EC 6001-01 Connection Cable 1 m .......................... 10 03 23101
EC 6001-02 Connection Cable 2 m .......................... 10 03 23201
EC 6001-05 Connection Cable 5 m .......................... 10 03 23501
EC 6001-10 Connection Cable 10 m ....................... 10 03 24102
EC 6001-20 Connection Cable 20 m ....................... 10 03 24202
EC 6001-50 Connection Cable 50 m ....................... 10 03 24502