DANHAG APP-control Operating Manual

Page 1
APP - Control
Version v10.x
as of 02.2018
Operating manual
Page 2
Front view
Antenna
Release
SIM card
SMA
connection
Rear view
Release
(connector I)
PIN1 PIN8
GPS LED Release
(connector II)
Page 3
Table of content
1 Scope of delivery............................................................................................. 5
2 Safety instructions........................................................................................... 6
3 Intended use................................................................................................... 6
4 Obligation and liability.................................................................................... 7
5 Malfunction..................................................................................................... 8
6 Disposal........................................................................................................... 8
7 Declaration of conformity...............................................................................8
7.1 Typengenehmigung..............................................................................8
8 Device description........................................................................................... 9
8.1 Difference BASIC / W-BUS / E-BUS........................................................9
8.2 Alarm function................................................................................... 11
8.3 Switching acknowledgment................................................................ 12
8.4 Status LED, GPS LED............................................................................ 12
9 SIM-card........................................................................................................ 13
9.1 Inserting the SIM card........................................................................ 13
10 Inputs and Outputs (connector I)................................................................14
11 electrical connection................................................................................... 16
11.1 connection to the heater.................................................................. 16
11.2 Connection of ext. button.................................................................17
12 Accessories connection............................................................................... 18
12.1 External temperature sensor............................................................18
12.2 GPS-receiver..................................................................................... 18
13 Start up....................................................................................................... 20
14 Configuration.............................................................................................. 21
14.1 Table parameter .............................................................................. 24
14.2 Configuration with SMS configurator................................................25
14.3 Configuration with mobile phone ....................................................25
14.4 Delete a phone number ................................................................... 25
14.5 Reset................................................................................................ 25
14.6 SMS-commands................................................................................26
15 Trouble shooting......................................................................................... 28
16 Manufacturer.............................................................................................. 29
17 technical data.............................................................................................. 29
18 Copyright..................................................................................................... 29
19 Installation location..................................................................................... 30
Page 4
Page 5
APP-control v10.x
1 Scope of delivery
APP-control
GSM-antenna (straight)
connection line (14-pole connector)
operating manual
optional available accessories
vehicle-specific cable harnesses
indoor window antenna
Antenna adapter (FME to SMA)
GPS-receiver
external temperature sensor
5 - 32
Prior to insertion of the SIM card please deactivate the PIN request and the mailbox and delete all telephone numbers that may be stored.
The operation of the GSM remote control will require any SIM card which is not included in the scope of delivery.
Page 6
APP-control v10.x
2 Safety instructions
Prior to the commissioning ot the device please read this operating manual completely. Additionally you have to observe the generally valid and the local regulations for accident prevention and environmental protection. Keep the operating manual. Do not operate the device in a surrounding where flammable gases, vapors, liquids or dust are existing or my exist.
3 Intended use
The APP-control allows the switching of any device per APP, SMS or call. The APP-control is designated for private use and not for commercial purposes. The APP-control has to be used exclusively according to the instructions of thes operating manual. The manufacturer is not liable for damage which are caused by inappropriate use or incorrect operation.
6 - 32
Do not use the APP-control if due to a malfunction danger and / or damage may occur.
The installation must only be carried out by a qualified technican.
Page 7
APP-control v10.x
4 Obligation and liability
The APP-control has been developed and manufactured according to the current technical status and the recognized safety rules. It cannot be assured, however, that the APP-control will operate as intended under all circumstances, at any time and under all conditions.
The DANHAG APP-control is manufactures in compliance with the EU directive 2011/65/EG (RoHS 2). this directive determines the use of hazardous material in devices and components.
The compliance with the prescribed EMC limit values was confirmed by an independent EMC testing laboratory.
Our products are recorded in the register for waste electrical equipment and meet the requirements of the relevant, applicable CE regulations. We confirm the observation of European standards on our devices by the CE marking. WEEE Reg. No.: DE 33181931
We only use sales packaging licensed by the disposal company “Zentek duales System”.
7 - 32
Do not use the APP-control for the switching of life­support systems or devices with an emanating danger due to an uncontrolled switching on and off.
Page 8
APP-control v10.x
5 Malfunction
The APP-control must taken out of service immediately when it might be assumed that a safe operation cannot be guaranteed any more. All appropriate measures must be taken to exclude an unintentional re-commissioning. Only a qualified person os allowed to perform a repair.
6 Disposal
This product must be taken to an official collecting point for disposal. You can also give back the product to the manufacturer for ecological disposal.
7 Declaration of conformity
The device is complying with the EU regulation 2004/108/EG (electromagnetic compatibility). Applied standards: EN 50498 / 2011
7.1 Typengenehmigung
8 - 32
E1 10R - 058021
This product must kept out from the domestic waste. Please dispose the product according to the applicable legal provisions only.
Page 9
APP-control v10.x
8 Device description
8.1 Difference BASIC / W-BUS / E-BUS
The versions are supporting different output signals as shown at the table.
output signal / Version output
BASIC W-BUS E-BUS PIN
+12V +12V +12V 2
ground ground ground 3
+12V W-BUS 3 E-BUS 3 1
W-BUS 4 E-BUS 4
W-BUS 5 E-BUS 5
W-BUS 6 E-BUS 6
E-BUS 7
E-BUS 8
9 - 32
The APP-control "W-BUS" and "E-BUS" are supporting different output signals. An overview about the signal needed for your vehicle or heater can be found at our website: www.danhag.de
Page 10
APP-control v10.x
8.1.1 Status
You can query the current status of the heater by sending a sms with the text "INFO" to the APP-control.
BASIC, W-BUS
The status displays the state of the APP-control.
E-BUS
The E-BUS version communicates with the heater and can display the current state of the heater.
8.1.2 Status messages
E-BUS only
Status messages are deactivated with the default settings. When status messages are enabled, you will be notified via SMS either when:
the heater was started successfully
the heater could not be started
the heater was turned off
10 - 32
Status messages are not supported from all vehicles / heaters.
Page 11
APP-control v10.x
8.1.3 Operating time
You can configure a default run-time via SMS. If you switch on the heater by APP, SMS or Call, the heater will use this run-time. If you switch the heater by APP or SMS, you can define a run-time of 10, 20, 30, 40, 50 or 60 minutes. The heater will run for this time once and than uses the default value again.
E-BUS only
The APP-control queries the operating-time from the vehicles board-computer. If the operating-time can't be queried, the default value will be used.
8.2 Alarm function
The APP-control is equipped with an alarm input which can be connected to an existing alarm system.
After connecting the power supply to the APP-control, the voltage level on the alarm input will be stored (0 or +12V). As soon as this level changes, the alarm will be triggered and all stored numbers are informed by call and SMS.
11 - 32
Factory installed alarmsystems are often integrated into the vehicles bus-system. Further information about how to connect these system can be found at our website:
www.danhag.de
Page 12
APP-control E-BUS v10.x
8.3 Switching acknowledgment
8.3.1 Switching by call
When switching the APP-control by call, you will hear a dial tone. During this time the caller's ID will be analyzed. In case of a valid phone number th switching operation will be released and you will hear a busy tone.
8.3.2 Switching by APP or SMS
You can query the current switching state of the APP-control by sending a SMS with the text “INFO” to the APP-control.
8.4 Status LED, GPS LED
Die LEDs zeigen den aktuellen Zustand des Gerätes und des GPS-Empfängers an.
Status LED
flashing green (every 3s) Standby (logged in)
lighting green Heater is switched on
flashing red Network search (not logged in)
lighting red fault
GPS LED
off GPS-receiver off
flashing red (every 1s) no GPS-reception
flashing green (every 1s)
GPS-reception OK
12 - 32
Page 13
APP-control v10.x
9 SIM-card
Any SIM card is required for the operation of the APP-control (Prepaid or subscription).
9.1 Inserting the SIM card
Disconnect the power supply from the device
remove the SIM card holder
(Pleas press the „release button“ slightly to release the holder)
insert the SIM card into the holder
push the SIM card into the device
connect the power supply
13 - 32
Page 14
APP-control v10.x
10 Inputs and Outputs (connector I)
PIN color description function
1 yellow Switching output 1 W-BUS, E-BUS
2 black Switching output 2 Output +12V, max. 1A
3 purple Switching output 3 ground, max. 500mA
4 output GND output GND 1KOhm for ext. LED
5 green input +12V Input for ext. button / switch
Button: one impulse (approx. 1s) is turning the Switching outputs alternately on and off ("on" for preset time) Switch: as long as +12V are applied the Switching outputs are activated (max. for preset time)
6 output +12V output +12V for ext. Taster
7 red power supply • +12V (fuse with 5A)
8 brown ground • Ground connection
9 not in uses
14 - 32
Page 15
APP-control v10.x
PIN color description function
10 Relais nc
11 Relais com
12 Relais no
13 blue input alarm
+12V / GND
Input for an existing alarm system
(see alarm function)
14 orange input ignnition
15 - 32
The inputs and outputs marked with "•" must be connected for the basic functionality of the device. All further connections can be used optionally.
Page 16
APP-control v10.x
11 electrical connection
11.1 connection to the heater
11.1.1 heater without radio remote control
The APP-control comes with an universal connection cable. Connect the APP­control to the power supply (red +12V, brown ground) and the yellow wire to the control-pin of the heater.
11.1.2 heater with radio remote control
The APP-control is connected to the already existing receiver of the remote control, using the y-cable which is included into delivery. The Y-cable also ensures the power supply of the APP-control.
disconnect the original cable from the receiver
connect the y-cable to the receiver
connect the original cable to the y-cable
connect the APP-control to the Y-cable
16 - 32
An overview about the mounting place of the receiver can be found at our website: www.danhag.com
Page 17
APP-control v10.x
11.2 Connection of ext. button
The button / switch is connecting PIN6 (+12V) with PIN5 of the 14-pole connector. There is a ground signal on PIN4 present as long as the switching output is active. PIN4 has a resistor integrated to drive a LED directly.
11.2.1 Difference between button and switch
Button: Pressing the button shortly (approx. 1s) will switch on the heater for the preset time. If you want to switch of the heater you have to press the button once again.
Switch: The heater is running as long as the switch is closed, but max. for the preseted time.
17 - 32
white
green
brown
DANHAG button
14pol. connector of APP-control
1 7 14 8
Page 18
APP-control v10.x
12 Accessories connection
The 4-pole accessories connection (connector II) is located at the rear side of the device. You can connect an external temperature sensor or an GPS-receiver. If you want to connect both devices, you willl need a Y-cable which is available as accessory.
12.1 External temperature sensor
The measured values are far more accurate.
12.2 GPS-receiver
The APP-control supports an external GPS-receiver which can be connected to the aux-socket at the back of the module. If the ignition is switched on the position is determined about every 1 second and can be queried via SMS. If the ignition is switched off, the GPS-receiver is activated during determining the position only.
You will get a SMS containing the current coordinates of the car as well as a link to “google maps” which shows the current position on the map.
18 - 32
When you connect an external temperature sensor, the sensor must be activated via SMS. Please send a sms with the following text to the APP-control: 12345;35=1;#
Page 19
APP-control v10.x
Ignition ON
You can query the position via SMS “GPS”. If the ignition is switched on the position is determined about every 1 second. If The Ignition is switched off, you will get the last known position.
Ignition OFF
You can query the current position via SMS “XGPS”. The GSP-receiver is activated for about 3 minutes to determine the position.
19 - 32
The GPS-receiver must be activated when used for the first time. Please refer to the manual delivered with the GPS­receiver.
If you want to update the position when the ignition is turned off, you will have to send a SMS with the text „XGPS“ to the APP-control. The GPS-receiver is turned on for about 3 minutes and determines the current position. If the receiver doesn't get any valid information, the last known position will be used.
The „E-BUS“ version determines the current state of the ignition via the vehicles data-bus. You will not have to connect the ignition separately.
Page 20
APP-control v10.x
13 Start up
Prior to start-up please read the complete instruction manual.
Disable the PIN-request of the SIM-card
insert the SIM-card into the APP-control
connect the APP-control to the 14-pole connector
wait until the APP-control is logged-in (Status-LED flashing green)
configure the APP-control
After connecting the power supply , the APP-control will perform a selftest. The LED will be lighting red for approx. 4 seconds and then begins to flash red (network search). As soon as the APP-control is logged in into the GSM network, the LED will be flashing green. Now, the APP-control is ready to operate and can be configured.
20 - 32
Please deactivate the PIN query prior to the insertion of the SIM card. Otherwise the APP-control cannot log in into GSM network. Therefore please insert the SIM card – if required - in a "normal" mobile phone and use the function "Deactivate PIN query".
Page 21
APP-control v10.x
14 Configuration
After the first start you have to configure the APP-control per SMS once. The settings are stored, even in case of disconnecting the power supply.
The following functions and settings can be configured:
Password
for the SMS configuration you will need the 5-digit password
the password can be modified and must consist of 5 figures
(preset "12345")
after a reset the password will be set back to “12345”
Running time
Determines how long the heater is switched on. To configure an impulse, set the runntime to 0 minutes, 2 seconds.
21 - 32
The maximum run-time is limited internally to about 30 or 60 minutes at some heaters. Regardless of the configured time, the heater will shut down after the maximum rub­time.
Page 22
APP-control v10.x
Switch-on delay (BASIC, W-BUS)
Determines if switching output 2 is switched simultaneously with output 1. You can configure a switch-on delay, so output 2 will be switched after output 1.
Switch-off delay (BASIC, W-BUS)
Determines if switching output 2 and 3 are switched off simultaneously with output 1. You can configure a switch-off delay, so output 2 and 3 will be switched off after output 1.
Output signal (Basic, W-BUS, E-BUS)
Determines the outputsignal on pin 1 (yellow wire)
Alarm delay
Determines how long the alarm signal must be present continuously before the alarm is triggered.
22 - 32
The switch-on delay is supported from output 2 only. The switch-off delay is supported from output 2 and 3.
The output-signal is already preconfigured for vehicle specific APP-controls.
Page 23
APP-control v10.x
Phone numbers / Master number
you can specify 5 authorized phone numbers
Phone number 1 is the master number to which all info SMS will
always be sent
The APP-control will perform the switching operation only if it is switched by one of the authorized phone numbers per APP, SMS or call
Status notification
Determines if and which status reports will be sent by the GSM remote control.
0 : all status reports deactivated
1 : only fault messages
2 : only switch-on messages
4: only switch-off messages
23 - 32
Please enter the phone number with the international prefix (e.g. +49 for germany). The phone number must not exceed 17 digits in total.
If you want to be informed about several events, you have to add up the corresponding numbers. E.g. for fault and switch-off messages you have to enter 5. (1 + 4 = 5)
Page 24
APP-control E-BUS v10.x
14.1 Table parameter
Nr. function setting remark
00 Password 5 digits preset "12345"
11 Master number max. 17 digits Enter phone numbers with
international prefix.
Germany +49 ... Austria +43 ...
e.g. +49171345678
12 Phone number 2
13 Phone number 3
14 Phone number 4
15 Phone number 5
20 Running time 10 - 255 Running time in Minutes
21 Switch-on delay 0 - 255 Minutes (not E-BUS)
22 Switch-off delay 0 – 255 Minutes (not E-BUS)
23 Running time 0 - 59 Seconds
30 Outputsignal 1 - 8
33 Status notification 0 - 7
35 Ext. temp. Sensor 0 - 1 0 = not connected
1 = connected
40 Alarm delay 0 - 251 sek 251: alarm deactivated
24 - 32
Page 25
APP-control v10.x
14.2 Configuration with SMS configurator
Please use the SMS configurator on „www.danhag.de“ for the configuration. Alternatively you can also generate and send the SMS with your mobile phone. After successful configuration the GSM remote control will send an SMS with an overview of the current settings to the master number.
14.3 Configuration with mobile phone
Each function and / or setting has an assigned number. The assignment of the respective parameter is carried out by a „=“ sign. Close up each input with a „;“. You can summarize several functions in one SMS (max. 150 digits). Finish the configurations SMS with „#“.
Example SMS
The example SMS configures the GSM remote control as follows:
Masternumber 1: 0305627853
Phone number 2: 01706878981
Running time: 25 minutes
Syntax:
12345;11=+49305627853;12=+491706878981;20=25;#
14.4 Delete a phone number
You can delete a phone number by overwriting it with "0".
14.5 Reset
To reset the APP-control, please disconnect the power supply for about 5 sec.
25 - 32
Page 26
APP-control v10.x
14.6 SMS-commands
You can control the GSM remote control by APP, SMS or call.
The following table shows the supported SMS commands.
command function
INFO Query of current settings
TEMP Query the temperature
ON switches the heater on
ON:20 switches the heater on for 20 minutes
(10, 20, 30, 40, 50, 60)
OFF switches the heater off
START0630 Timer function e.g.: heater starts at 6:30 am
STOP switches the heater off and deletes the timer
GPS Query of the last known GPS-position
1
XGPS Query of the current GPS-position
1
1
GPS-receiver required
26 - 32
If you use an APP for controlling the heating, it also sends the corresponding SMS commands in the background. Depending on your mobile phone contract, additional costs may occur due to the SMS sending. Switching the heater by calling is free of charge.
Page 27
APP-control v10.x
14.6.1 INFO SMS
You can query the current settings of the APP-control by sending an SMS with the Text "INFO" to the APP-control. Then you will receive an SMS with a summary of the settings to the master number.
27 - 32
Status
Status of heater
(on, remaining time) (off, running time)
Timer
Preset start time
Alarm
Alarm delay
Signal
Field strength(0 - 31)
(10: bad, 31: good)
Info
Status notifications
PWD
Current password
SW
Software version
DANHAG
Status: off (20min)
Timer: off Alarm 3s Signal: 21 Temp: ext INFO: 7
PWD: 12345 SW: v10.x
Page 28
APP-control v10.x
15 Trouble shooting
Fault descriptionfault fault Cause of fault
LED flashing rapidly red
GSM module not logged in
• PIN query not deactivated
• SIM not correctly inserted
• no reception
LED lighting up shortly red, every 60s
Under-voltage on module
Check supply voltage and the fuse (5A)
No switching operation at all
Not / incorrectly configured
• Phone number existing twice on SIM card
• APP-control not configured yet
delete all phone numbers / SMS on SIM cardand re-configure
No INFO-SMS query possible
Kno credit on SIM card of APP­control
Load credit
Heater is not running during preset timet
Under-voltage on heater or maximum heating time achieved
Check vehicle battery
APP-control cannot be configured
wrong password (PWD)
after reset the PWD will be set to "12345"
28 - 32
Page 29
APP-control v10.x
16 Manufacturer
Ing. Büro Gornicki Boizenburger Str. 30 D - 12619 Berlin E-Mail: info@danhag.de Webseite: www.danhag.de
17 technical data
Supply voltage: 10 - 15 VDC Current consumption: Standby ca. 10mA, shortly max. 2A Switching output 1: E-BUS Switching output 2: +12V, max 1A Operating temperature: -30°C bis 80°C Dimensions: 64 x 60 x 22mm (L x B x H) zzgl. Antenne
18 Copyright
All brands and trademarks mentioned in this operation manual and possibly protected by third parties are unlimitedly subject to the regulations of the respectively valid trademark law of the respectively registered owners. The bare mentioning does not allow the conclusion that brands are not protected by rights of third persons. The brands and trademarks mentioned in this operation manual are property of the respective copyright holder and are only used descriptively.
Reproduction, copying and publication are allowed with written approval only. (c) Ing. Büro Gornicki
29 - 32
Page 30
APP-control v10.x
19 Installation location
Mark the installation location of the APP-control.
30 - 32
Page 31
Page 32
Please visit www.danhag.de for an german version of this users guide.
*740409*
740409
Loading...