Dangerous Powers G3 IQ StockBoard User Manual

B
ASE FIRING MODES
Mode Description
Dangerous Powers G3/IQ Stock Board
LED
P
OWER
ON
B
F
S S F
ATTERY LEVEL
IRING OPERATIONS
OLID GREEN (BALL IN BREECH LOW GREEN (EMPTY BREECH AST GREEN
OK (
(E
YES OFF
GREEN FLICKER
)
), LOW B
/ M
ARKER LOADED
/ M
ARKER NOT LOADED
ATTERY LEVEL (RED FLICKER
)
)
)
Semi
Fires 1 shot for each trigger pull
Three shots in Semi then transitions to 3 Round
PSP3
Burst. Returns to Semi after 1 Second of no activity.
Semi for the first 3 shots, then Full Automatic on
NXL
the 4th pull and hold. Resets to Semi after 1 second of no Activity
Fires required three shots in Semi, then Semi
Millennium
M
ARKER CONTROL SETPOINTS
Feature LED
MGRF Firing Mode
Ramp Point
Trigger Debounce
Solenoid Dwell
ABS Dwell
until transition to double rate of fire when trigger pull rate >= Ramp Point. Resets to Semi after trigger release or pull rate < Ramp Point.
Value
Red 13 5/25
Green 1 1/4
Yellow 3 1/10
Red Flash 7 1/31
Green Flash 15 5/25
Yellow Flash 4 1/4
Default
Min/Max
Value
T
RIGGER
F
IRING MODE OPERATION
IN F
AT POWER UP
P
ROGRAMMING MODE OPERATION
IN P S
ETPOINT VALUES VIA TRIGGER PULLS
IRING MODE, FIRES THE MARKER
.
ROGRAMMING MODE
, C
. I
NVOKES PROGRAMMING MODE
YCLES THROUGH SETPOINTS AND ENTERS
.
MARKER CONTROL SETPOINT DEFINITIONS
MGRF – This sets the “Eyes On” Max Global Rate of Fire (in Balls per second) of all firing modes. A setting of 25 operates the marker in “Uncapped” mode for NPPL semi tournament play. PSP and NXL formats require 13 BPS,/ Millennium requires 12 BPS. User is responsible for legal program settings.
Firing Mode – This value determines the Power On Firing Mode of the marker. 1 = Semi, 2 = PSP3, 3 = NXL, 4 = Millennium. User is responsible for legal program settings.
Ramp Point – Determines the ramping point of the currently assigned Firing Mode. Tournament legal setting is 3 for PSP/NXL modes / 6 for Millennium Mode. User is responsible for legal program settings.
Trigger Debounce –
also control the trigger optical sensitivity. A debounce value of 1-15 provides the most sensitive optical trigger operation, and a debounce time proportional to the setpoint. A value of 16-31 provides a less sensitive trigger (requiring more physical travel across the optical sensor), and a debounce time equal to the setpoint value minus 15 (example: setpoint value of 25 = debounce of 10ms / 25-10 = 10).
Solenoid Dwell – This value controls the amount of time (in milliseconds) the solenoid is energized. If too low, the marker will not cycle. If the value is too high, the solenoid remains on too long, wasting battery power and air.
ABS Dwell – Adds an additional 1-3 milliseconds of dwell time to the programmed solenoid dwell setpoint on the first shot of any string of shots after a fixed 20 seconds of shooting inactivity. A value of 4 disables the ABS Dwell feature.
NON-ADJUSTABLE FEATURES (ALWAYS ON):
MGRF Eyes OFF – When the Eyes are shutoff, the MGRF is overridden to 10 BPS.
Breech/Eye Delay – This value controls the amount of time (in milliseconds) the eyes must see a ball in the breech prior to cycling the bolt. This will be a fixed 3
milliseconds and will compensate for different paint grades and feed methods. This delay will be run in series with all the bolt related timing.
Auto Shutoff – The marker will shut off automatically after 20 minutes of NO firing activity.
Trigger Buffering - This buffers a trigger pull during the bolt cycle, resulting in your marker firing more smoothly in all modes.
Battery Monitor – Sampled only when Power Button is pressed to conserve overall battery life.
This value sets amount of time (in milliseconds) the trigger must remain inactive prior to accepting a new trigger pull. It can
P
OWER BUTTON
P
OWER
ON
P
RESS/HOLD UNTIL
LEVEL
). R
P
P
AND MARKER IS OFF
EYE C
TAP TO T
P
ELEASE AND MARKER IS READY TO FIRE
OWER
OFF
RESS/HOLD
2 S
ONTROL
OGGLE
ROGRAMMING EXAMPLE
LED
ECONDS UNTIL
.
EYE
DISABLE/ENABLE
ILLUMINATES (DISPLAYS BATTERY
LED
TURNS OFF
.
Setting the Firing Mode to PSP3 from Default SEMI mode:
1. Start Programming Mode
2. LED is SOLID RED (MGRF setpoint). Pull trig­ger to scroll to next setpoint.
3. LED is SOLID GREEN (Firing Mode setpoint). Tap the power button to select this setpoint.
4. LED flashes current value repeatedly. Tap power button again to reprogram this setpoint.
5. Pull the trigger 2 times, observing 1 LED flash per pull
6. Tap the power button once more to save the new setpoint value.
7. Returns to Step 4.
8. Pull trigger to scroll to another setpoint or power off marker.
FOR
HELP WITH YOUR NEW DANGEROUS POWER
G3/IQ
BOARDS, PLEASE CONTACT US AT
S
UPPORT@DANGEROUSPOWER.COM
OR C
ALL
(909)869-7800
.
. R
ELEASE
: