[1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18]
FC-102 – – – – ––––––X–SXX X–X– – –CX–X–XX–
[1] Application
102 VLT® HVAC Drive FC 102
[2] Power Size
P1K1
P1K5
P2K2
P3K0
P3K7
P4K0
P5K5
P7K5
P11K
P15K
P18K
P22K
P30K
P37K
P45K
P55K
P75K
P90K
See ratings data on page 22
for power ratings
P110
P132
P160
P200
P250
P315
P355
P400
P450
P500
P560
P630
P710
P800
P900
P1M0
P1M2
P1M4
[3] AC Line Voltage
T2 3 x 200/240 V AC (1.1 – 45 kW)
T4 3 x 380/480 V AC
T6 3 x 525/600 V AC (1.1 – 90 kW)
T7 3 x 525/690 V AC (45 kW – 1.2 MW)
[4] Enclosure
For cabinet mounting:
E00 IP 00/Chassis (enclosure D3, D4)
E20 IP 20/Chassis (encl. A2, A3, B3, B4, C3, C4)
Standalone:
IP 21/Type 1 (encl. B1, B2, C1, C2, D1, D2,
E21
E, F)
E54 IP 54/Type 12 (encl. D1, D2, E, F)
E55 IP 55/Type 12 (encl. A5, B1, B2, C1, C2)
E66 IP 66/ Type 4x Outd. (en cl. A5, B1, B2, C1, C2)
Special designs:
IP 00/Chassis
C00
(encl. E00 – air duct in stainless steel)
P20 IP 20/Chassis (encl. B4, C3, C4 – Back Plate)
IP 21/Type 1 (encl. D1, D2 – protective
E2M
cover)
P21 IP 21/Type 1 (encl. as E21 – Back Plate)
IP 54/Type 12 (encl. D1, D2 – protective
E5M
cover)
P55 IP 55/Type 12 (encl. as E55 – Back Plate)
[5] RFI Filter (EN 55011)
H1 RFI-Filter Class A1/B (A, B, C)
H2 RFI-Filter, Class A2 (A, B, C, D, E, F)
H3 RFI -Filter Class A1/B (A, B, C)
H4 RFI-Filter, Class A1 (D, E, F)
H6 RFI-Filter for Marine
HX No RFI-Filter (A, B, C, 525 – 600 V)
[6] Braking & Safety
X No brake IGBT
B Brake IGBT mounted
T Safe stop without brake
U With brake and Safe Stop
[7] Display (Local Control Panel)
X Blank faceplate, no LCP installed
G LCP 102 – Graphic LCP installed
N LCP 101 – Numeric LCP installed
[8] Conformal Coating (IEC 721-3-3)
X No conformal coating
C Conformal coating on all PCBs
[9] Mains Input
X No option
1 Mains disconnect
3 Mains disconnect and fuses
5 Mains disconnect, fuses and load sharing
7 Fuses
A Fuses & load sharing terminals
D Load sharing terminals
[10] Cable
X Standard Cable Entries
O
Metric Cable Entries
US cable entries
S
[13] A Option (Fieldbus)
AX No eldbus option
A0 MCA 101 – Pro bus DPV1
A4 MCA 104 – DeviceNet
AG MCA 108 – LonWorks
AJ MCA 109 – BACnet
[14] B Option (Application)
BX No application option
BK MCB 101 – General Purpose I/O
BP MCB 105 – Relay Expansion
B0
MCB 109 – Analogue I/O
MCB 102 – PTC Thermistor Card
B2
[18] D Option (Control Power Backup Input)
DX No DC input installed
D0 MCB 107 24 VDC backup input
Please beware that not all combinations are
possible. Find help con guring your drive with
the online con gurator found under:
drivecon g.danfoss.com
Based on your selection, Danfoss manufactures
the desired VLT® HVAC Drive to your speci cation. You will receive a fully assembled frequency converter, tested under full load conditions.