Universal Service Thermostat
Danfoss universal service thermostats are kitted with all the necessary accessories for standard applications, ensuring a quick and easy
installation. Thanks to the integrated enclosed brake device, these controls can be safely used in isobutene or propane refrigeration systems.
Features
Universal Service
Thermostat
Rated to 16 A
Enclosed brake device permits
use with ammable refrigerants
Snap action contact function
permits long lifespan
Includes all common installation
fasteners and accessories
Facts
Applications:
• Traditional refrigeration
• Self-contained refrigerators
• Reach-ins
• Bottle coolers
• Under counter refrigerators
• Eight kit options
• Fixed cut-in and constant dierential options available
• Enclosed brake device permits use with
ammable refrigerants
• Contact Load: 16 A (120V)
• Kit includes:
- Thermostat
- Mounting bracket
- Adjustment knob
- Fasteners
18
Quick Select Guide
Technical data and ordering
Universal Service Thermostat
Application
Refrigerator Constant Cut-in 38/28 38/19 38/9
Refrigerator Constant Cut-in 41/29.5 41/23.5 41/17
Refrigerator/
Freezer
Refrigerator/
Freezer
Low Temp.
Freezer
Low Temp.
Freezer
Low Temp.
Freezer
Operation
mode
Adaptable Constant
Dierential
Adaptable Constant
Dierential
Adaptable Constant
Dierential
Adaptable Constant
Dierential
Adaptable Constant
Dierential
Warm pos.
cut-in/cut-out
Temperature Range (°F)
Middle pos.
cut-in/cut-out
36/26 21.5/9 3/−14
36/26 21.5/9 3/−14
16.5/7 4.0/−7.5 −11/−25.5
9.5/3 −3/−11 −18.5/−29
9.5/3 −3/−11 −18.5/−29
Cold pos.
cut-in/cut-out
Sensor
type
Coiled
Bulb
Straight
Sensor
Straight
Sensor
Straight
Sensor
Straight
Sensor
Straight
Sensor
Straight
Sensor
Capillary tube
length (in.)
39
84
42
84
84
42
84
Competitor
Model No.
A12-1506
A12-710
A12-711
A12-700
A12-701
A12-1560
A12-712
A30-180
A30-182
A30-184
A30-185
A30-181
A30-183
A30-260
A30-263
A30-301
A30-307
A30-310
A30-311
A30-313
A30-308
A30-314
Danfoss
Code No.
077Z7010
077Z7011
077Z7012
077Z7013
077Z7014
077Z7015
077Z7016
Refrigerator
Adaptable Constant
Dierential
47/36.5 37.5/25.0 25.5/10.0
Straight
Sensor
66
All controls feature an enclosed brake device to permit use with amable refrigerants and are kitted with adjustment knob,
installation fasteners, and mounting bracket.
120V 240V
Contact Load
Full Load Amps 16A 8A
Locked Rotor Amps 96A 40A
A22-391
A22-1112
077Z7017
Quick Select Guide
19