Danfoss Electronics TE 5, TE 12, TE 20, TE 55 Installation Guide

Instructions
Orifice for TE 5 55 and PHT
067R9609
TE5 TE12 / TE20 TE55 PHT
Orifice
Type
TE5
TE20
TE55 TE55
Old code Type New Code
No.
1 067B2089 067B2789 1 3.49 12.20 4.26 14.90 5.60 19.60 5.46 19.10 26
2 067B2090 067B2790 2 4.86 17.00 5.86 20.50 7.77 27.20 7.51 26.30 26
3 067B2091 067B2791 3 6.23 21.80 7.51 26.30 9.94 34.80 9.66 33.80 26
4 067B2092 067B2792 4 8.49 29.70 10.20 35.70 13.50 47.40 13.10 46.00 26
1 067B2005
2 067B2006
3 067B2007
4 067B2008
1 067B2172
1 067B2170 067B2771 8 22.20 77.80 24.90 87.10 33.70 118.00 36.60 128.00 34
1 067B2175 067B2771 8 22.20 77.80 24.90 87.10 33.70 118.00 36.60 128.00 34
1 067G2005 067G2704 11 34.90 122.00 39.40 138.00 50.00 175.00 52.60 184.00 32,5
1 067G2001 067G2704 11 34.90 122.00 39.40 138.00 50.00 175.00 52.60 184.00 32,5
1 067G2011 067G2704 11 34.90 122.00 39.40 138.00 50.00 175.00 52.60 184.00 32,5
2 067G2006 067G2710 13 47.40 166.00 52.00 182.00 66.30 232.00 70.00 245.00 32,5
2 067G2002 067G2710 13 47.40 166.00 52.00 182.00 66.30 232.00 70.00 245.00 32,5
2 067G2012 067G2710 13 47.40 166.00 52.00 182.00 66.30 232.00 70.00 245.00 32,5
1) change to TE5 valve body and element
1)
1)
1)
067B2788 0.5 1.91 6.68 2.33 8.17 3.06 10.70 2.97 10.40 26
TE5
067B27891)2 4.86 17.00 5.86 20.50 7.77 27.20 7.51 26.30 26
067B27911)3 6.23 21.80 7.51 26.30 9.94 34.80 9.66 33.80 26
067B27921)4 8.49 29.70 10.20 35.70 13.50 47.40 13.10 46.00 26
067B2708 5 10.80 37.70 14.50 50.70 15.90 55.80 16.30 57.20 37
TE12
067B2709 6 14.30 50.10 18.30 64.00 21.10 73.90 21.80 76.30 37
067B2710 7 18.80 65.70 23.20 81.30 26.90 94.30 27.90 97.80 37
067B2771 8 22.20 77.80 24.90 87.10 33.70 118.00 36.60 128.00 34
TE20
067B2773 9 26.40 93.30 29.10 102.00 38.90 136.00 42.90 150.00 34
067G2705 9B For specifications, please contact Danfoss
067G2701 10 31.70 111.00 36.60 128.00 46.00 161.00 48.30 169.00 32,5
067G2707 12 38.30 134.00 43.40 152.00 54.60 191.00 57.70 202.00 32,5
TR kW TR kW TR kW TR kW Y-value
Orifice
R134a R404A/507 R407C R22
no.
Factory setting
SS = 4oC (7oF)
Nominal capacity
Factory
settings
067R9609
© Danfoss A/S (AC-AKC sw) 07-2011 DKRCC.PI.A00.E2.02 /520H5464
Loading...