Danfoss Electronics SGP X, SGP I, SGP N, SGP RX, SGP RI Installation Guide

...
Installation guide
Danfoss
14-47.15
Danfoss
Dr
Sight glass
Type SGP X, SGP I, SGP N, SGP RX, SGP RI, SGP RN, SGR, SGI, SGRI, SGN, SGRN
Refrigerant: SGP (I indicator): R290, R600, R600a, R22 SGP (N indicator): R410A, R404A, R507, R134a, R407C, R32, R22, R1270, R744, R407A, R407F, R448A, R449A, R450A, R452A, R513A, R454B, R1234ze
014R9572
SG (I indicator): R22 SG (N indicator): R22, R134a,R404A, R407C, R507, R407A,R407F, R448A,R449A,R450A, R452A,R513A
For complete list of approved refrigerants, go to http://products.danfoss.com/all-products/ For the application use with R744 as part of a secondary loop or cascade system should refer to the
datasheet for more attentions.
014R9572
Media temperature: T T
Green Grün Vert Verde Verde
綠色
Verde зеленый
: -50 °C / -58 °F
: +80 °C / +175 °F
max.
Yellow Gelb Jaune Amarillo Giallo
黄色
Amarelo желтый
Type W W
mm in. mm in. SGP/SG flare 6 SGP/SG flare 10 SGP/SG flare 12 SGP/SG flare 16 SGP/SG flare 19
14 19 22 27 11/ 32 11/
9
/
16
16
3
/
22
4
7
/
24
8
27 11/
16
32 11/
4
Danfoss
14-50.15
Max. working Pressure PS / MWP: SGP: 52 bar / 754 psig SG: 35 bar / 508 psig
Danfoss
14-210
y N
2
5
/
8
7
/
8
15
/
16
16
4
Max. 80 °C / 175 °F
d>22 mm – 7/8 in.
SGP/SG socket max. torque 100 N m / 74 ft-lbs
Danfoss
14-67.15
14-125.12
Min. 5% Ag
Size Nm ft-lbs
1
/4 in / 6 mm
3
/8 in / 10 mm
1
/2 in / 12 mm
5
/8 in / 16 mm
3
/4 in / 19 mm
© Danfoss | DSC (sw) | 2017.01
Max. torque
20 15 30 22
60 44 100 74 200 148
With O-ring max. torque 50 Nm / 37 ft-lbs
Hex 27 mm / 11/16 in
Hex 32 mm / 11/4 in
DKRCC.PI.EK0.D8.02 | 1
Sight glass type SGP X, SGP I, SGP N, SGP RX, SGP RI, SGP RN, SGR, SGI, SGRI, SGN, SGRN
Only SGP solder version are allowed for ammable refrigerants
All Danfoss products fulll the requirements in REACH. One of the obligations in REACH is to inform customers about presence of Candidate list substances if any, we hereby inform you about one substance on the candidate list:
A moisture indicator in a sight glass contains a paper which is impregnated with Cobalt Dichloride (CAS no: 7646-79-9) in a concentration above 0.1% w/w. If the valve has been damaged or dismantled:
- Avoid skin contact with the paper
- Do not inhale the dust from the paper
- The paper must be disposed as hazardous waste
© Danfoss | DSC (sw) | 2017.01
DKRCC.PI.EK0.D8.02 | 2