Danfoss Electronics MCD 200 Features and Benefits

VLT® Compact Starter MCD 200
The VLT® Compact Starter MCD 200 from Danfoss includes two families of soft starters in the power range from 7.5 to 110 kW.
The series oer easy DIN rail mount­ing for sizes up to 30 kW, 2-wire or
Compatible with grounded delta
power systems. 3-wire start/stop control and excellent starting duty (4 x Ie for 6 seconds).
Power range
7.5 – 110 kW Heavy starting ratings at 4x Ie for 20 seconds.
Feature Benet
Small footprint and compact size – Saves panel space
– Minimises installation cost and eliminates
Built-in bypass
Advanced accessoires – Allows enhanced functionality Advanced SCR Control Algorithms balances
output waveform
User friendly Save commissioning and operating cost
Easy to install and use – Saves time Easy DIN rail mounting for sizes up to 30 kW – Saves time and space
Reliable Maximum uptime
Essential motor protections (MCD 202) – Reduces overall project investment Max. ambient temperature 50° C
without derating
power loss
– Reduces heat build up. Savings in
components, cooling, wiring and labor
– Allowing more starts per hour, accepting
higher load
– No external cooling or oversizing necessary
Perfect
match for: – Pumps – Fans – Compressors – Mixers – Conveyors – and many more
MCD 201 MCD 202
MCD 202 provides enhanced soft start functionality and various motor protection features
U
Ramp up
Initial torque
Ramp down
M
3~
I
Current
limit
Initial current
Ramp up
Facts about our products
U
Ramp down
M
3~
Soft Starter for motors up to 110 kW
n Total motor starting solution
Start, stop and protection features
n
Local programming keypad and
n
display
Optional
n
Modules for serial communication:
– DeviceNet
– Probus – Modbus RTU – USB
Remote operator kit
n
PC software
n
Pump application module
n
Specications
Mains supply (l1, L2, L3)
Supply voltage
Supply frequency 45 – 66 Hz
Control voltage
Control inputs
Control inputs
Relay outputs
Relay outputs
Protections, MCD 201
Protections, MCD 202
LED indications
Indications
Ambient operating temperature
Ambient temperature -5 to 60˚C (above 40˚C without derating)
Standards approvals
Approvals CE, UL, C-UL, CCC, C-tick, Lloyds
3 x 200 VAC – 440 VAC or 3 x 200 – 575 VAC
100 – 240 VAC 380 – 440 VAC 24 VDC/24 VAC
Start, Stop Reset upsh button on the unit
1 x main contactor 1 x programmable* (Trip or Run)
Phase sequence Supply fault Shorted SCR
Motor thermistor input Motor temperature – thermal model Phase imbalance Phase sequence Excess start time Supply fault Shorted SCR
Ready/Fault Run
Remote operator kit
Remote Operator and display with 4–20 mA analogue output propor­tional to motor current (MCD 202) Serial communication: Modbus RTU, AS-i, Probus and DeviceNet. PC-based MCD set-up software.
Cabinet sizes
Power range (400 V) 7 – 30 kW 37 – 55 kW 75 – 110 kW
Height [mm] Width [mm] Depth [mm]
203 215
98 145
165 193
240 202 214