VLT® Soft Start Controller MCD 100
MCD 100 is a cost eective and extremely compact soft starter for AC motors up to 15 HP. Due to a unique semiconductor design
MCD 100 is a true “t and forget” product. Selection can be made on the basis of the motor power—exactly as with traditional
contactors.
The new range features three dierent products, MCD 100-001
(2 HP), MCD 100-107 (10 HP), and MCD 100-011 (15 HP). In fact
the MCD 100-001 is the world’s smallest soft starter rated up
to 2 HP. All sizes are rated for line voltages up to 600 VAC.
MCD 100 products provide timed voltage ramp up and down.
Ramp time can be individually adjusted with rotary switches
from 0.4 to 10 seconds. The start torque can be adjusted from 0
to 85% of the direct on-line torque.
Application
MCD 100 is an ideal alternative when starting smaller AC
motors direct on-line or with a star-delta starter. The typical
applications would be soft start / stop of conveyor systems,
pumps, and soft start of smaller compressors, for example
scroll or reciprocating compressors in air-conditioning units.
MCD 100 products can be installed side by side and with or
without a line contactor. Motor protection must be installed
separately. Short circuit protection can be achieved by the use
of fuses or a circuit breaker.
Perfect
match for:
- Pumps
- Fans
- Compressors
- Mixers
- Conveyors
- and many more
Application example of a motor controlled by MCD 100 and protected
by a circuit breaker.
Benets with MCD 100 over traditional small soft
starters
A robust semiconductor design – selection can be based on
motor power which ensures easy selection. It can be used for an
almost unlimited number of starts per hour without derating.
A universal control voltage (24-480 VAC / VDC)—simplies
selection and keeps stock at a minimum.
A “t and forget” contactor design—simplies installation
and reduces required panel space.
Digitally controlled rotary switches—secures precise settings
and simplies installation.
Ratings for heavy duty as standard—simplies installation
and reduces the risk of breakdown.
Specication and ordering code numbers
Type
MCD 100-001 1 HP 3 A 208 – 240 V 175G4000
MCD 100-001 2 HP 3 A 400 – 415 V 175G4001
MCD 100-001 2 HP 3 A 440 – 480 V 175G4002
MCD 100-001 3 HP 3 A 550 – 600 V 175G4003
MCD 100-007 5 HP 15 A 208 – 240 V 175G4004
MCD 100-007 10 HP 15 A 400 – 480 V 175G4005
MCD 100-007 10 HP 15 A 500 – 600 V 175G4006
MCD 100-011 10 HP 25 A 208 – 240 V 175G4007
MCD 100-011 15 HP 25 A 400 – 480 V 175G4008
MCD 100-011 20 HP 25 A 500 – 600 V 175G4009
Max Power- Top to
Bottom
Max. FLC Voltage Code number
Technical data
MCD 100-001 MCD 100-007 MCD 100-011
Dimensions (width) .88 inches 1.77 inches 3.54 inches
Load rating (EN 60947-4-2) 3A:5-5:10
Semiconductor protection
Type 1 25 A gL/gG 50 A gL/gG 80 A gL/gG
Type 2 72 A2s 1800 A2s 6300 A2s
Power loss Max. 4 W 2 W/A x duty cycle
Ambient temperature -5 C to 40 C (above 40 C with derating)
Approvals CE, cULus (UL508)
15A:8-3:100-3000
25A:8-3:100-3000