Solenoid valves Type EVU for fluorinated refrigerants
EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and servo operated versions, they can be applied in liquid, suction, and hot gas lines with fluorinated refrigerants. EVU solenoid valves can be used in many different refrigeration systems and are specially designed for:
y commercial refrigeration systems y refrigeration appliances y liquid coolers y ice cube machines y mobile refrigeration systems y heat pump systems y air conditioning units
EVU valves are available in straightway or angleway design. All valves are semi hermetically sealed and are not serviceable. The standard coil is available with 3-core cable connection, DIN plug and 0.25 US spade. EVU valve bodies and coils are ordered separately.
Features
Approvals
© Danfoss | DCS (az) | 2018.06
y Compact construction small dimensions,
low weight for both valve and coil.
y Semi-hermetic construction. Metallic sealing
between armature tube and valve body. Bimetal connections to the brass housing Benefits:
– high strength of joints and high
vibration resistance
− maximum external tightness within the whole temperature and pressure operation range
y Bimetal connections simple, fast soldering
without the need of wet cloth or refrigration pliers.
• UL Recognized Component (Canadian and US)
y Direct and servo operated mini piston compact
solenoid valve.
y Universal application for
− liquid, suction, and hot gas applications
− reduced power consumption
y Simple and fast mounting of coil
− clip - ON / OFF
y Small encapsulated coils with long life time
under extreme conditions.
y Refrigerants:
R744, R22 / R407C, R404A / R507, R410A, R134a, R407A, R23. For other refrigerants, please contact Danfoss.
y Large MOPD range − up to 36 bar.
• Pressure Equipment Directive (PED) 2014/68/EU
• Low Voltage Directive (LVD) 2014/35/EU
DKRCC.PD.BD0.4A.22 | 1
Data sheet | Solenoid valve, type EVU for fluorinated refrigerants
Technical data
Refrigerants
R744, R22 / R407C, R404A / R507, R410A, R134a,
Ambient temperature
-40 – 140 °F R407A, R23. For other refrigerants, please contact Danfoss.
OPD operating range
M
0.029 psi up to 522 psi
Temperature of medium
-40 – 221 °F
Humidity
0 − 100% R.H. (0-97% R.H. non-condensation condition if IP level is below IPX5).
Opening differential pressure
with standard coil p
Typ e
Min.
[psi]
Max. (=MOPD) liquid
8 W AC [°F] [psi] [gal / min]
EVU 1 0.000 348
3)
2
Temperature
of medium
Max. working
pressure
C
-40 – 221 1015 0.11
– value 1
v
EVU 2 0.029 522 -40 – 221 1015 0.23
EVU 3 0.029 522 -40 – 221 1015 0.35
EVU 4 0.029 522 -40 – 221 1015 0.58
EVU 5 0.029 522 -40 – 221 1015 0.76
EVU 6 0.029 522 -40 – 221 1015 0.93
EVU 8 0.029 522 -40 – 221 1015 1.15
1
 Cv value is the water flow in [gal / min] at a pressure drop across valve p = 1 psi, ρ = 10 lbs / gal
2
 MOPD for media in gas form is approximately 14 psi greater
3
 For coil 208 – 240 V, 60 Hz, MOPD is 250 psi
MOPD (Max. Opening Pressure Differential) is measured with highest media and ambient temperature and 15% below nominal voltage
Metric conversions:
• 1 psi = 0.07 bar
•5/9 (t1 °F -32) = 12 °C
• 1 TR = 3.5 Kw
• 1 in = 25.4 mm
• 1 ft = 0.3 m
• 1 lb = 0.454 kg
• 1 oz = 28.35 gram
• US gal / min = 0.86 m3 / h
1
 / [TR]
R404A /
R507
R410A
R22 /
R407C
R134a
R404A / R507
R410A
Typ e
R22 /
R407C
Rated capacity
Liquid Suction vapour Hot gas
R134a
R404A / R507
R410A
R22 /
R407C
R134a
EVU 1 0.64 0.48 0.44 0.64 0.55 0.04 0.05 0.06 0.12 0.10 0.10 0.18
EVU 2 1.27 0.96 0.87 1.27 0.11 0.08 0.09 0 .13 0.24 0 .19 0.19 0.36
EVU 3 1.9 0 1.45 1.31 1.90 0.16 0.12 0.14 0.19 0.35 0.29 0.28 0.53
EVU 4 3 .19 2 .41 2.18 3.17 0.26 0.20 0.23 0.32 0.59 0.48 0.47 0.89
EVU 5 4 .12 3.13 2.83 4.12 0.34 0.26 0.30 0.42 0.76 0.62 0. 61 1.16
EVU 6 5.07 3.86 3.49 5.07 0.42 0.32 0.37 0.51 0.94 0.77 0.76 1.42
EVU 8 6.34 4.83 4.36 6.34 0.53 0.40 0.46 0.64 1.18 0.96 0.95 1.78
1
 Rated liquid and suction vapor capacity are based on:
- evaporating temperature t
- liquid temperature ahead of valve t
- pressure drop p across valve
- with liquid p = 2 psi for R134a, p = 3 psi for R22 / R407C, R404A and R507 with suction vapor p = 1 psi
-
Rated hot gas capacity is based on:
- condensing temperature t
- hot gas temperature th = 140 °F
- pressure drop across valve p = 2 psi
= 40 °F
e
= 100 °F
c
= 100 °F
l
© Danfoss | DCS (az) | 2018.06
DKRCC.PD.BD0.4A.22 | 2
Data sheet | Solenoid valve, type EVU for fluorinated refrigerants
Ordering valve
EVU 1– EVU 6
EVU 8
Single pack
1 product in a box with installation guide
Multi pack
box with x pieces single pack (can be split)
Industrial pack
x pieces in one box (cannot be split)
0.25 in. US spade connections
0.25 in. US spade connection
Single pack
1 product in a box with installation guide
Multi pack
box with x pieces single pack (can be split)
Industrial pack
x pieces in one box (cannot be split)
Normally closed NC
Typ e
[in.] [mm] Code no. Pcs. Code no.
EVU 1
EVU 2 6 032F5053 40 032F9529
EVU 3
EVU 4 10 032F5037 40 032F9531
EVU 5
EVU 6
EVU 8 12 032F8009 40
The valve code numbers on above are with coil sealing O-ring. This should be removed For US-coils with the external Frame.
Connection Industrial pack Mutiple pack
1
4
/
032F7005 40 032F9524
6 032F7004 40
1
4
/
032F5024 40 032F9525
6 032F5025 40 032F9530
3
8
/
032F5026 40 03 2F5111
10 032F5027 40
3
8
/
032F7000 40 032F9526 10 032F7001 40 032F9532 12 032F7003 40
3
8
/
032F5046 40 032F9527 10 032F50 47 40
1
2
/
032F50 49 40 032F9528 12 032F5048 40 032F9533
Alternating current AC with US spade IP00
Typ e
Tem p.
[°C]
AY240C -40 – 50
AY120C -40 – 50
AY02 4C -40 – 50
Ambient
Supply
voltage
[V]
Voltage
variation
Frequency
[Hz]
208 – 240 -15% – 10% 50 8.0 16 208 – 240 -15% – 10% 60 8.0 16
110 – 120 -15% – 10% 50 8.0 16 110 – 120 -15% – 10% 60 8.0 16
24 -15% – 10% 50 8.0 16 24 -15% – 10% 60 8.0 16
Power
consumption
Industrial pack Multi pack
[W] [VA] Code no. Pcs. Code no.
042N8230 40 042N4230
042N8233 40 042N4233
042N8236 40
Alternating current AC with US DIN spade IP00
Typ e
Tem p.
[°C]
AZ240CS -40 – 50
AZ120C S -40 – 50
AZ024CS -40 – 50
Ambient
Supply
voltage
[V]
Voltage
variation
Frequency
[Hz]
230 -15% – 10% 50 8.0 16
208 – 240 -15% – 10% 60 7. 0 14
115 -15% – 10% 50 8.5 16
110 – 120 -15% – 10% 60 7. 0 14
24 -15% – 10% 50 9.5 18 24 -15% – 10% 60 7. 0 14
Power
consumption
Industrial pack Multi pack
[W] [ VA] Code no. Pcs. Code no.
042N8201 40 042N4201
042N8202 40 042N4202
042N8203 40 042N4203
Accessories
© Danfoss | DCS (az) | 2018.06
Part Description
DIN plug (EN175301-803 type A)
O-ring for sealing the coil. Industrial pack (50 pcs.)
NB: Valve body suppplied with O-ring
.FW
Danfoss
32M20.10
Bracket for fixing of valve. 032F8036 40
Code no.
Multi
pack
Pcs.
Industrial
pack
042N 0156
03 2F6115
DKRCC.PD.BD0.4A.22 | 3
Pcs.
Data sheet | Solenoid valve, type EVU for fluorinated refrigerants
Capacity Liquid capacity
[TR]
o
Typ e
Liquid capacity Q
at pressure drop across valve p [bar]
1 2 3 4 5 6 7
R22 / R407C
EVU 1 0.34 0.52 0.64 0.73 0.82 0.85 0.97
EVU 2 0.68 1.03 1.27 1.46 1.63 1.79 1.93
EVU 3 1.02 1.55 1.90 2.19 2.45 2.69 2.90
EVU 4 1.69 2.59 3 .17 3.66 4.09 4.48 4.84
EVU 5 2.20 3.36 4 .12 4.75 5. 31 5.83 6.29
EVU 6 2.71 4.14 5.07 5.85 6.54 7.17 7.74
EVU 8
3.39 5.18 6.34 7. 31 8.18 8.96 9.68
R134A
EVU 1
EVU 2 0.68 0.96 1.18 1.3 6 1.52 1.67 1.80
EVU 3 1.02 1.45 1.77 2.05 2.29 2.51 2.71
EVU 4 1.71 2. 41 2. 59 3. 41 3.81 4.18 4.84
EVU 5
EVU 6 2.73 3.86 4.73 5.45 6 .10 6.68 7. 22
EVU 8 3.41 4.83 5.91 6. 81 7.63 8.35 9.03
0.34 0.48 0.59 0.68 0.76 0.84 0.90
2.22 3 .13 3.84 4.43 4.96 5.43 5.86
R404A/507
EVU 1 0.25 0.36 0.44 0. 51 0.57 0.62 0.67
EVU 2 0.50 0.71 0.87 1. 01 1.13 1.23 1. 33
EVU 3 0.76 1.07 1. 31 1. 51 1. 69 1. 85 2.00
EVU 4 1.26 1.78 2.18 2.52 2.81 3.09 3.33
EVU 5
EVU 6 2.02 2.85 3.49 4.03 4.50 4.94 5.33
EVU 8 2.53 3.56 4.36 5.04 5.63 6.18 6.66
1.6 4 2. 31 2.83 3.27 3.66 4.01 4.33
Metric conversions
• 1 psi = 0.07 bar
• 5/9 (t1 °F - 32) = t2 °C
• 1 TR = 3.5 kW
© Danfoss | DCS (az) | 2018.06
R410a
EVU 1 0.34 0.52 0.64 0.73 0.82 0.90 0.97
EVU 2 0.68 1.03 1.27 1.46 1.63 1.79 1.93
EVU 3 1.02 1.55 1.90 2.19 2.44 2.69 2.90
EVU 4 1.69 2.59 3 .17 3.66 4.07 4.48 4.84
EVU 5 2.20 3.36 4 .12 4.75 5.29 5.83 6.29
EVU 6
EVU 8 3.39 5.18 6.34 7. 31 8 .14 8.96 9.68
Capacities are based on:
- liquid temperature tl = 100 °F,
- evaporating temperature te = 40 °F,
- superheat temperature (te + 10 °F) = 50 °F.
Correction factors for liquid temperature t
tl [°F] 80 90 100 110 120
Factor 1.10 1.05 1.0 0 0.95 0.90
When liquid temperature t multiplying them by the appropriate correction factor found in the following table.
2.71 4.14 5.07 5.85 6.51 7.17 7.74
l
ahead of the expansion valve is other than 100 °F, adjust the table capacities by
l
DKRCC.PD.BD0.4A.22 | 4